Introduction
The PAL System is a versatile platform for sample preparation and handling, supporting methods like liquid and gas injection, headspace sampling, and solid phase extraction. It is widely used in chromatography and spectroscopy by over 50,000 users.

Features & Benefits
The PAL RTC and RSI systems enhance productivity and flexibility. The RTC offers robotic tool change for continuous operation, while the RSI provides a cost-effective solution with upgrade options.

PAL RTC
The RTC system features automatic tool selection and workflow configuration, supporting complex workflows and automation of labor-intensive tasks.

PAL RSI
The RSI system is reliable and flexible, supporting various sampling methods and accommodating a range of syringes and valves.

PAL DHR Dual Head
This system increases productivity with two independently moving heads, supporting applications like automated weighing and high-throughput LCMS injections.

Tools and Modules
The PAL System includes tools for liquid, gaseous, and solid samples, such as liquid syringes and SPME fibers. Modules like the agitator and barcode reader enhance functionality.

PAL Sample Control & Method Composer
The software facilitates efficient operation and workflow setup, with a user-friendly interface for creating and testing sample prep methods.

Applications
The system supports a wide range of applications in analytical and clinical labs.

Specifications
Technical specifications are detailed, outlining the system's capabilities.
Modules and Tools
  • Heatex Stirrer Module: Mixes and heats samples with a temperature range of 30° - 150°C and stirring speeds up to 1600 rpm.
  • Large Wash Module: Suitable for large volume injections with two 100mL solvent containers.
  • Solvent Module: Contains three 100mL solvent containers for large solvent demands.
  • SPME Fiber Conditioning Module: Conditions fibers up to 350°C with a purge gas connection.
  • Valve Drive Module: Supports various valve types for fast switching and stackable design.
  • Vortex Mixer Module: Efficient mixing for standard vial sizes with speeds up to 2000 rpm.
Software and Productivity
  • PAL Sample Control: Optimizes productivity by overlapping steps and reducing runtimes.
  • PAL Method Composer: Allows intuitive method generation using drag-and-drop functionality.
Applications
  • Automated procedures for blood sample processing and liquid-liquid extraction.
  • Real-time monitoring of off-flavour compounds using SPME-GC-MS/MS.
Accessories and Consumables
Emphasizes the importance of small parts like vial caps and syringes for reproducible results.
Specifications
Includes dimensions and capacities for various configurations, supporting a wide range of vial sizes.
Injection Specifications
  • Overfill: 10 µL in a 20 µL loop.
  • Liquid injection linearity: R > 0.9999 for volumes 20-100 µL.
  • Small sample volume injection: 3 injections of 1 µL from a 5 µL sample.
  • Carryover: Less than 30 ppm measured with LC/MS Tool.
GC Application Specifications
  • Injection volume range: 0.1-10000 µL.
  • GC liquid injection repeatability: Less than 0.60% RSD for Alkanes C14-C16.
  • GC liquid injection linearity: R > 0.9999 for volumes 20-100 µL.
  • GC headspace injection repeatability: Less than 1.00% RSD for Iso-octane.
  • GC needle discrimination: C40/C20 > 0.98.
Additional Information
  • Detailed specifications available upon request.
  • Visit www.palsystem.com for more information.
  • Contact experts for sample preparation or find the nearest reseller.
Note: PAL is a registered trademark of CTC Analytics AG, Switzerland.
See more

Catalog excerpts

PAL RSI and PAL RTC Sample Prep and Injection-1

SYSTEM Ingenious sample handling PAL RSI and PAL RTC Sample Prep and Injection

 Open the catalog to page 1
PAL RSI and PAL RTC Sample Prep and Injection-2

PAL System’s new generation of sample preparation and handling instruments.

 Open the catalog to page 2
PAL RSI and PAL RTC Sample Prep and Injection-4

The PAL System is one of the most widely used and successful sample preparation and handling platforms. 4

 Open the catalog to page 4
PAL RSI and PAL RTC Sample Prep and Injection-5

The PAL System is one of the most widely used and successful sample preparation and handling platforms. PAL System is your tool box for sample preparation, from a simple liquid injection to complete workflows. A PAL System can be adapted or extended to meet almost any requirement. Numerous options allow to increase sample capacity or add further modules for sample preparation. Listed below are the method steps that a PAL System can perform: – – – – – – – – – – Liquid injection GC and LC – Gas injection – Liquid addition – Headspace sampling – Dynamic headspace sampling – SPME and SPME Arrow sampling...

 Open the catalog to page 5
PAL RSI and PAL RTC Sample Prep and Injection-6

Sample preparation is the key to success to achieve precise and accurate results. For a typical chromatographical analysis 61 % of time is spent on sample prep, 30 % of errors are linked to sample prep*. Time Spent on Typical Chromatographic Analysis Sources of Error Generated During Chromatographic Analysis Columns Contamination Data Management Sample Preparation Collection Analysis Sample Introduction Chromatography Integration Instrument Calibration * data taken from the book “SAMPLE PREPARATION FUNDAMENTALS FOR CHROMATOGRAPHY” from Agilent Techologies.

 Open the catalog to page 6
PAL RSI and PAL RTC Sample Prep and Injection-7

PAL RTC - Highest Productivity & Flexibility The PAL RTC with Robotic Tool Change is the logical (r)evolution of the successful PAL-xt product line. It is a robotic platform for the efficient and safe automation of most sample preparation steps. The robotic change of tools enables unattended 24/7 operation, even for multistep workflows and thereby greatly increases the productivity of labs. At the same time process safety is optimized since all operations become traceable. PAL RSI - The Workhorse The RSI is the robust workhorse for analytical labs. It is the cost effective solution for labs in...

 Open the catalog to page 7
PAL RSI and PAL RTC Sample Prep and Injection-8

Robotic Tool Change (PAL RTC only) The unique Park Station enables the Robotic Tool Change, for productivity - With different syringes available always the ideal one can be selected, for instance one syringe is reserved for standard addition to minimize carryover while 2 others are used for dilution steps. - The RTC speeds up SPME method development by allowing automatic sampling of different types of SPME fibers. - The PAL RTC identifies type of tool and its position automatically. - 162 x 2mL or 60 x lOmL or 20mL vials/tray holder, other vial types and microtiter plates can be handled. -...

 Open the catalog to page 8
PAL RSI and PAL RTC Sample Prep and Injection-9

! Injector correct position wrong position detected Process safety Missing vial detected Position detection means process safety. Missing vials or the correct position of the injector are detected and traced. Position detection for the temperature controlled stack ensures that the drawer is in the correct position (open / closed) and the temperature is monitored. Minimized carryover and reproducible injection of minute sample volumes Bottom sensing makes sure that small volumes can be injected out of a few µL of sample (e.g. 3 x 1µL out of 5µL). With Constant Force Technology the PAL detects...

 Open the catalog to page 9
PAL RSI and PAL RTC Sample Prep and Injection-10

The PAL RTC is all about increasing productivity. Robotic Tool Change takes productivity to a new level. PAL RTC with extended x-axis for LC/MS Automation improves process safety Automation is the way to increase productivity and (process) safety in the laboratory. Transferring repetitive or dangerous manual tasks to a robot improves safety. The possibility to run the instrument 24h/day increases throughput, especially for long sample preparations. The PAL RTC was developed to maximize productivity in analytical and clinical labs. Robotic Tool Change (RTC) brings sample preparation to a higher...

 Open the catalog to page 10
PAL RSI and PAL RTC Sample Prep and Injection-11

Park Station for Robotic Tool Change PAL RTC with standard x-axis for GC & GC/MS Ingeniously productive. – – – Automatic selection of the syringe with optimal accuracy for adding standards or preparing serial dilutions On the fly switching between a syringe tool for the addition of an internal standard and the LC/MS Tool for subsequent analysis Possibility to permanently configure several workflows on one system for a walk-up prep station, e.g. Liquid/ Liquid Extraction and Solid Phase Extraction (SPE) Automated optimization of methods e.g. by selecting the most suitable Solid Phase Micro Extraction...

 Open the catalog to page 11
PAL RSI and PAL RTC Sample Prep and Injection-12

The PAL RSI is the reliable workhorse for analytical labs. The PAL RSI defines the industry standard for intelligent sample preparation. PAL RSI with extended x-axis for LC/MS Ingeniously reliable. Laboratories work under time pressure and often with a tremendous workload. The reliability of hardware and software should not be something the user has to worry about. Reliability is just expected from every tool. That is exactly what the PAL RSI was designed for. It is a tool that you can rely on. 50.000 PAL systems worldwide are proof of this.

 Open the catalog to page 12
PAL RSI and PAL RTC Sample Prep and Injection-13

PAL RSI with standard x-axis for GC & GC/MS The most flexible system on the market. RSI is a flexible tool. Its open and modular architecture makes it the most versatile system on the market. Tools can be exchanged readily within minutes. PAL customers working with GC love the possibility to use liquid, headspace or SPME sampling on the same system. LC customers use the PAL because of its huge sample capacity, the range of syringes and valves available.

 Open the catalog to page 13
PAL RSI and PAL RTC Sample Prep and Injection-14

Transport vial 1 to balance Place vial 1 back Get weighed vial 1 Add sample 2 to vial 2 Workflow 1 (Head 1) Workflow 2 (Head 2) Injection using Head 2 Transport vial 2 to balance

 Open the catalog to page 14
PAL RSI and PAL RTC Sample Prep and Injection-15

PAL DHR DUAL HEAD Productivity x2 – Two heads can move independently – The heads can execute two independent workflows Headspace sampling with standard addition Parallel injections into two GC- or LC-systems – The software optimizes the time table to maximize productivity – Collision control → process safety and easy programming – 120 or 160 cm wide working area – Combinations of RTC/RSI heads – With an RTC head toolchange expands the options further Application Examples – Automated weighing of samples, combined with the analysis of a weighed sample – High troughput LCMS injections with 2 completely...

 Open the catalog to page 15