SPECIFICATION Product Name: Laser Particle Count Sensor Module Item No.: PM5100 Version: V0.2 Date: 2023.12.28
Open the catalog to page 1Revision No. Version! Contend Date 2 V0.2 Update operating voltage 2023.12.28
Open the catalog to page 2Laser Particle Count Sensor Module PM5100 Applications Pharmaceutical industry Electronics industry Food hygiene industry Finishing clean room, precision test area Description The PM5100 laser particle count sensor module adopts the principle of optical scattering, which can accurately detect and calculate the number of suspended particles of different particle sizes in the air per unit volume, and can simultaneously output the number of 0.3μm, 0.5μm, 1.0μm, 5.0μm, 10μm particles ( pcs/28.3L). 5-chanel (0.3μm, 0.5μm, 1.0μm, 5.0μm, 10μm) simultaneous particle numbers output in pcs/28.3L Industrial...
Open the catalog to page 3Table 2. Table of pin definitions
Open the catalog to page 5Typical Application Circuits Figure 2 Typical application circuit diagram of UART communication Notice for circuit design: ※The UART communication level is 3.3V. ※ PIN3, PIN4, PIN7 are the ports for internal debugging and should be left floating in the application circuit.
Open the catalog to page 61) The data of this protocol are all hexadecimal data. For example, "46" is [70] in decimal; 2) [xx] is single-byte data (unsigned, 0-255); double-byte data high byte first, low byte after; 3) Baud rate: 9600, DataBits: 8, StopBits: 1, Parity: No. 4) After the mode is set, it will not be saved when power off. The power-on default is continuous mode. Sending format of software: 4.1 Read Particle Measurement Result Send: 11 02 0B 07 DB Response: 16 35 0B DF1- DF52 [CS] Function: Read measurement result. Note: Read particles quantity.
Open the catalog to page 7>0.3|jm particle count = DF25*256A3 + DF26*256A2 + DF27*256A1 + DF28 >0.5pm particle count = DF29*256A3 + DF30*256A2 + DF31*256A1 + DF32 >1.0jm particle count = DF33*256A3 + DF34*256A2 + DF35*256A1 + DF36 >5.0jm particle count = DF41*256A3 + DF42*256A2 + DF43*256A1 + DF44 >10jm particle count = DF45*256A3 + DF46*256A2 + DF47*256A1 + DF48 Note: The reserved bits are used for internal testing, and their value changes have no meaning. 4.2 Query sensor code 4.3 Setting and reading particulate calibration coefficients Send: 11 02 07 DF1 CS //Set the particle calibration coefficient Send: 11 01 07...
Open the catalog to page 8Sensor Dimension Figure 3 Dimensions (unit mm, tolerance ±0.2mm)
Open the catalog to page 9User Attention ※ When this product is installed and used in the system, the air inlet and outlet should be unobstructed, and there should be no large airflow facing the inlet and outlet air; the internal cross-section diagram of the sensor and the recommended installation method are as follows, so as to avoid dust deposition in the sensitive process during use. The surface of the device affects the test accuracy of the sensor. Figure 4 Internal section of the sensor Figure 5 Recommended installation method ※ The size of the ventilation hole opened for the air inlet on the inner wall of the user...
Open the catalog to page 11After-Sales Services and Consultancy Cubic Sensor and Instrument Co., Ltd Add: Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China E-mail: [email protected] Tel: +86 (0)27 81628827 Fax: +86 (0)27 81628821 Website: http://www.gassensor.com.cn
Open the catalog to page 121 Page
3 Pages