video corpo

Working with custo flash 500
2Pages

{{requestButtons}}

Catalog excerpts

Working with custo flash 500 - 1

Holter ECG with custo flash 500/501/510 To ensure that data can be saved on the SD card, the write protection lock must be in the upper position as shown. Solution The custo multiday card must be configured in the custo flash 5xx recorder, so that it can be recognised by the device. To do so, insert the custo multiday card into the flash 5xx recorder. Ensure that the direction of insertion corresponds to the label in the recorder. Then insert the rechargeable battery. The configuration starts. The process is completed when the LED flashes green slowly. Remove the custo multiday card from the recorder (gently press the edge of the card), and reinsert the card into the card reader. The above error message also appears if the card reader is faulty. Check whether the card reader is functioning properly. Ensure that the custo multiday card is recordable. If the write protection is active, it is not possible to record an ECG on the SD card. LO Error description After setting the recording parameters and selecting a patient for the recording, data cannot be saved on the custo multiday card because the device does not detect the card. 7 Note on the custo multiday card 5 Error message: multiday card not detected 8 Attaching the electrodes Adjust the neck strap so that the recorder is placed centrally on the patient’s chest. Shave, clean and dry the electrode application points. Apply the two top electrodes under the collarbone, if possible not on a muscle. Apply the bottom electrode below the heart or on the breastbone. The electrodes can be applied at a slightly different positions within the blue frames. This Quick Guide contains the 6 Setting the recorder time most important information for proper operation of the custo flash 5xx Holter ECG recorder. Start custo diagnostic and open the page Examination, Holter, Settings, Connection, multiday card. In the multiday card area click on the set recorder time button (right side of the display). The time is set in four steps. The program provides you with specific instructions. Quick Guide | Holter ECG with custo flash 500/501/510

Open the catalog to page 1
Working with custo flash 500 - 2

2 LED display during recorder start RED custo multiday card detected GREEN Quickly Configuration of the custo multiday card, may take several minutes Configuration of the custo multiday card completed GREEN Slowly 4 Using the rechargeable battery and charger Recording mode 3 Further LED statuses, error display 1 LED display, recorder keys When starting for the first time: custo multiday card faulty, recording not possible The rechargeable battery must only be charged at an ambient temperature between 10 – 45°C. The battery must not be charged when exposed to direct sunlight or on the...

Open the catalog to page 2

All Custo med GmbH catalogs and technical brochures

  1. Holter ECG

    12 Pages

  2. Holter-ABPM

    12 Pages

  3. custo kybe

    2 Pages

  4. Spirometry

    2 Pages

  5. ABPM

    2 Pages

  6. Holter ECG

    2 Pages