Overview: This document is a package insert for the Guava® Instrument Cleaning Fluid (ICF) by Luminex Corporation, intended for research use only. It provides instructions on the use, handling, and storage of the cleaning fluid, which is essential for maintaining the performance of Guava® easyCyte™ and Guava Muse® Systems.
Symbols Glossary: A glossary of symbols is included, indicating warnings, instructions, and regulatory information.
Description: Guava ICF is formulated to clean the fluid systems of Guava instruments by removing clogs and residues. It can be used alone or mixed with bleach for enhanced cleaning.
Materials: The package includes Guava ICF. Additional materials required but not provided include bleach, micropipettors, and deionized water.
Warnings and Precautions: The fluid is for laboratory use only and contains irritants. Proper personal protective equipment (PPE) should be worn, and safety data sheets are available for more information.
Storage and Handling: Guava ICF should be stored at room temperature in a closed container and kept away from acidic reagents.
Assay Procedure: Instructions are provided for preparing and using Guava ICF, both alone and with bleach, for cleaning and disinfecting the systems. Specific procedures are outlined for different Guava systems, including the Muse®, easyCyte™, and PCA systems.
Troubleshooting: Guidance is provided for addressing issues such as clogs in the flowcell, with steps for cleaning and maintenance.
Instrument Maintenance Procedures:
  • If fluidics issues occur, especially with the Guava® ViaCount™ module, it is recommended to run Guava Check, easyCheck™, or System Check to evaluate instrument performance before proceeding.
  • For difficult clogs, perform a Backflush followed by multiple Quick Cleans using Guava ICF and deionized water. If the flow rate remains slow, conduct a Complete System Clean.
  • If checks indicate low particles/mL but normal scatter and fluorescence, partial clogging is suspected. Use Quick Clean with Guava ICF and DI water. If acquisition rates remain low, perform Clean and Shutdown cycles.
  • Regular use of Guava ICF is advised to clear buildup from cell samples and reagents. Follow Quick Clean with water to prevent contamination.
  • For sticky or clumpy samples, use Guava ICF intermittently with Quick Clean, followed by DI water rinsing.
  • If white, cloudy material is seen in the ICF bottle, invert the bottle several times or warm it to 37°C to reduce cloudiness.
Limitations: Results depend on the correct use of reagents, products, and instruments.
Legal and Trademark Information: This document is for research use only and not for diagnostic procedures. Luminex Corporation reserves the right to modify products and services without notice and assumes no liability for errors or damages from the use of this information. Luminex, Muse, and Guava are registered trademarks of Luminex Corporation.
See more

Catalog excerpts

Guava® Instrument Cleaning Fluid (ICF) Package Insert-1

Guava® Instrument Cleaning Fluid (ICF) Package Insert Technical Support Telephone: 512-381-4397 North America Toll Free: 1-877-785-2323 International Toll Free: + 800-2939-4959 Email: [email protected] www.luminexcorp.com For Research Use Only. Not for use in diagnostic procedures. 4600-0150, Rev M Catalog No. 4200-0140 01/2021 Luminex Corporation 12212 Technology Blvd. Austin, TX 78727 U.S.A.

 Open the catalog to page 1
Guava® Instrument Cleaning Fluid (ICF) Package Insert-2

Guava® Instrument Cleaning Fluid (ICF) Package Insert For Research Use Only. Not for use in diagnostic procedures.

 Open the catalog to page 2
Guava® Instrument Cleaning Fluid (ICF) Package Insert-3

Guava® Instrument Cleaning Fluid (ICF) Package Insert Symbols Glossary You will encounter these symbols throughout this manual. They represent warnings, conditions, identifications, instructions, and regulatory agencies. Biological risks Serial Number Contains sufficient for tests Catalog number Batch code Storage temperature range For Research Use Only. Not for use in Diagnostic Procedures Luminex Technical Support Contact Luminex Technical Support by telephone in the U.S. and Canada by calling: 1-877-785-2323 Contact outside the U.S. and Canada by calling: +1 512-381-4397 International: + 800-2939-4959...

 Open the catalog to page 3
Guava® Instrument Cleaning Fluid (ICF) Package Insert-4

Guava® Instrument Cleaning Fluid (ICF) Package Insert Description The Guava® easyCyte™ and Guava Muse® Systems operate with minimal maintenance and servicing, but the flowcell and fluid system require regular cleaning to ensure proper performance. Guava Instrument Cleaning Fluid (ICF) cleans the fluid system of the Guava easyCyte or Guava Muse System by effectively removing sample clogs and buildup from cell debris, proteins, and reagent dye residues. Although Guava ICF is supplied ready to use with no dilution required, you can mix Guava ICF with bleach as described in this package insert for...

 Open the catalog to page 4
Guava® Instrument Cleaning Fluid (ICF) Package Insert-5

Guava® Instrument Cleaning Fluid (ICF) Package Insert Causes skin and serious eye irritation. If on skin, wash with plenty of soap and water. If in eyes, rinse continuously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. Get medical advice/attention. 7. Wear appropriate personal protective equipment (PPE), including a lab coat and disposable gloves, when performing procedures. When using Guava ICF to clean your Guava PCA, Guava easyCyte™ System, or Muse® Cell Analyzer, hhandle all materials as if capable of transmitting infection. Dispose all...

 Open the catalog to page 5
Guava® Instrument Cleaning Fluid (ICF) Package Insert-6

Guava® Instrument Cleaning Fluid (ICF) Package Insert fail to reach the expected number of events after running Quick Clean. In addition, you can clean the system to clear stubborn clogs. Do not leave bleach or any other cleaning agent on the instrument overnight or for an extended period of time. Prolonged exposure to strong cleaning agents will damage the flowcell. Always flush the instrument extensively with water after using any cleaning reagent. At the end of a cleaning cycle always leave the capillary tip submerged in a 1.5 mL tube of fresh deionized water. NOTE: If acquiring whole blood...

 Open the catalog to page 6
Guava® Instrument Cleaning Fluid (ICF) Package Insert-7

Guava® Instrument Cleaning Fluid (ICF) Package Insert Clean the Guava® Muse® System NOTE: Always check the fluid levels in the cleaning and waste bottles whenever you run the Complete Clean procedure. Ensure the cleaning solution bottle is filled with Instrument Cleaning Fluid (ICF). 1. Select Muse System Cleaning under the Essential Tools at the main menu. Select Complete System Clean. Select Run Complete Clean. 4. Follow the prompts to load ICF, followed by deionized (DI) water. Select Finish if you are done, or Next Cleaning to run the Complete System Clean again. Always leave a tube of water...

 Open the catalog to page 7
Guava® Instrument Cleaning Fluid (ICF) Package Insert-8

Guava® Instrument Cleaning Fluid (ICF) Package Insert 4. Click Main Menu to return to the CytoSoft™ main menu or click Exit to close CytoSoft. NOTE: If you want to continue with data acquisition, launch the desired CytoSoft application and allow the laser to warm up for 5 minutes before resuming data acquisition. 5. Leave a tube of deionized (DI) water on the Guava PCA. Clean the Guava® easyCyte™ Mini System 1. Click Clean and Shut Down from the main menu. The Guava® Clean screen appears. Click Clean Only or Clean and Shut Down. a. Load a tube containing Guava Instrument Cleaning Fluid (ICF)...

 Open the catalog to page 8
Guava® Instrument Cleaning Fluid (ICF) Package Insert-9

Guava® Instrument Cleaning Fluid (ICF) Package Insert Click Quick Clean. Follow the prompts and load a tube containing Guava® ICF or Guava ICF with 10% bleach. Click OK. The cleaning solution runs for approximately 30 seconds. 4. Load a tube containing deionized (DI) water, then click Quick Clean again. 5. Verify that the deionized (DI) water tube is loaded, and then click OK to rinse out the cleaning fluid. Repeat as necessary to remove the clog. Clean a Clogged Flowcell for High-Throughput (HT) (Automated Instruments) If a sample in an automated instrument seems to be running slowly, pause...

 Open the catalog to page 9
Guava® Instrument Cleaning Fluid (ICF) Package Insert-10

Guava® Instrument Cleaning Fluid (ICF) Package Insert If a clog is difficult to clear using Quick Clean, perform a Backflush, then repeat the Quick Clean several times using Guava Instrument Cleaning Fluid (ICF) and deionized (DI) water. If the flow rate is still slow, perform a Complete System Clean procedure until the acquisition rate is normal. If Guava Check, easyCheck, or System Check shows a low particles/mL count and the scatter and fluorescence intensity results are normal, partial clogging is likely. Run Quick Clean using Guava ICF and again with DI water. If the acquisition rate is...

 Open the catalog to page 10
Guava® Instrument Cleaning Fluid (ICF) Package Insert-11

Guava® Instrument Cleaning Fluid (ICF) Package Insert © 2020-2021 Luminex Corporation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language or computer language, in any form or by any means without prior express, writ-ten consent of Luminex Corporation. Luminex Corporation (Luminex) reserves the right to modify its products and services at any time. This guide is subject to change without notice. Although prepared to ensure accuracy, Luminex assumes no liability for errors or omissions, or for any damages resulting from...

 Open the catalog to page 11

All Cytek® Biosciences Inc. catalogs and technical brochures

  1. Cytek®Aurora

    16  Pages

  2. qbsure

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.