1. Catalogs
  2. D-TEC
  3. D-TEC Lighitng Handbook

D-TEC Lighitng Handbook

D-TEC Lighitng Handbook
1 / 12 PagesView full catalog

D-TEC Lighitng Handbook

Product catalog summary
Introduction
This handbook from D-TEC highlights the importance of proper lighting in the workplace, emphasizing its impact on health and productivity. Poor lighting can lead to various health issues such as headaches, stress, and reduced productivity.

Impact of Lighting on Health
Light affects our circadian rhythm and hormone levels, influencing mood, sleep, and stress. Inadequate lighting can disrupt these processes, leading to health problems like sleeping disorders and stress.

Common Symptoms of Poor Lighting
  • Headaches
  • Sleeping problems
  • Stress
  • Tiredness
  • Lowered immune system
  • Neck, shoulder, and back problems
  • Lower productivity and more errors
  • Inability to match or select correct colors

Recommended Lighting Levels
Different areas require specific Lux levels for optimal lighting:
  • Operational lighting: 20,000 - 45,000 Lux
  • Surrounding lighting: 3,000 - 5,000 Lux
  • General lighting: 500 - 1,000 Lux

Color Rendering and Shadows
High CRI lighting (94 CRI) ensures accurate color perception. Advanced LED technology minimizes shadows and glare, improving working conditions.

Lighting Placement and Intensity
Proper placement of light sources is crucial as light intensity decreases with distance. Floating lamps can help maintain adequate lighting levels.

Lighting for Different Ages
Older individuals require more light due to changes in vision. A 60-year-old needs significantly more light than a 20-year-old.

Energy Efficiency and Eye Comfort
Switching to LED lighting can save energy and reduce eye strain. A balanced lighting setup with multiple sources can prevent glare and flicker.

Lighting Checklist
  • Avoid flickering, glare, and shadows
  • Ensure low contrast between light sources
  • Use light colors for walls and ceilings
  • Choose low thermal heating and noise-free sources
  • Ensure correct color rendering for specific professions
  • Position screens to avoid glare

Contact Information
D-TEC AB, Varavägen 12, SE-465 94 Nossebro, Sweden. Phone: +46 31 969 302, Email: [email protected], Website: d-tec.se
See more

Catalog excerpts

D-TEC Lighitng Handbook-1

Enlightening facts about light A lighting handbook from D-TEC

 Open the catalog to page 1
D-TEC Lighitng Handbook-2

Leaning forward in order to see better will most likely result in shoulder-, back- and neck ache. Strained eyes due to bad lighting can cause you a headache.

 Open the catalog to page 2
D-TEC Lighitng Handbook-3

Bad lighting – a workplace hazard? Despite the fact that light has a big impact on our circadian rhythm, where the hormone levels of melatonin and serotonin play an important role, many employers don’t see the lack of light ergonomics as a potential workplace hazard. But the symptoms tell us otherwise. With this handbook we hope to shed some light over the problem – and the solution. Melatonin and serotonin are in charge of regulating our mood as well as our eating- and sleeping habits. When spending most of our time indoors, our hormones aren’t regulated by the ultimate source of light – the...

 Open the catalog to page 3
D-TEC Lighitng Handbook-4

How many Lux do you have at your workplace? Did you know that a higher intensity of illumination provides better vision and lets you see smaller contrasts better? A typical office space typically offers around 1000 Lux, where 3000 - 5000 Lux is recommended for demanding workplaces. Contact your nearest D-TEC retailer to find out your Lux level. ZONE 1 Operational lighting Surrounding lighting General lighting Measure 70 cm from the light source. Measure 120 cm from the light source. Your level: Your level: Your level: COMMON LUX LEVELS • Direct sunlight: 100 000 Lux • A typical office space:...

 Open the catalog to page 4
D-TEC Lighitng Handbook-5

Perfect colour rendering? Check. Tired of heading over to the window when reviewing different colour shades? Note that the colour temperature (K) of the sun changes during the hours of the day and depending on the weather too. Therefore, we’re proud to offer you no less than 94 CRI on the Colour Rendering Index scale (the sun gives you 100 CRI), assuring you that the colour you pick is correct.

 Open the catalog to page 5
D-TEC Lighitng Handbook-6

Where did all the shadows go? Don’t be surprised if your patients will be asking where all shadows went! The secret? Hundreds of small LED sources work together to spread the light evenly with help from integrated micro prisms – leaving you with no shadows, better working conditions and fewer mistakes being made. If you want your light source to impress your patients even more, why not let your lamp show the colours of the rainbow or a soothing ever-changing flow of light! Sounds interesting? Check out our model Cloud

 Open the catalog to page 6
D-TEC Lighitng Handbook-7

Where should you place your light sources? Did you know that the intensity of the illumination is inversely proportional to the square of the distance? See illustration below. That said, an object of the same size that is located twice as far away, receives only one-quarter the same light. Therefore, we offer floating lamps, in order to get closer to the work area. Placement of light source

 Open the catalog to page 7
D-TEC Lighitng Handbook-8

Prepare yourself for a better night’s sleep – during your workday We’re not designed to live indoors using artificial lighting. But if you imitate the sun and choose an intense blue-rich light in the morning to help you staying alert (see the example with 6500 K to the right), and then switch to a warmer, softer light in the afternoon (3000 K), it helps you to wind down – and you will sleep better. If you don’t want to handle the switching, we offer an auto-dynamic daylight option in our range. Check out Clair seen to the right. How old are your employees? The reason we’re asking is that good...

 Open the catalog to page 8
D-TEC Lighitng Handbook-10

Good for the environment, your wallet and your eyes When making a switch to more efficient light sources like LED, you can start saving up to 85% on energy bills, from day one. You will also benefit from a low thermal heating, no acoustic noise and an increased light quality, since the technology provides more light per watt than its competitor. During a typical workday, your eyes are forced to change focus between a brighter operational light and the surrounding light over 1000 times. To avoid eye strain and headaches, you can lower the contrast between your existing light sources by applying...

 Open the catalog to page 10
D-TEC Lighitng Handbook-11

A frame milled in solid aluminium for maximum stability and efficient cooling. 2. A high-end reflector that reflects more than 98% of the light. A normal mirror reflects 80 - 90%. 3. A light guide plate that transports and spreads the light from the LED’s to make a large lit surface, rather than several spots. This reduces glare and makes it much more comfortable for the patient. 4. Thin diffusing sheet that diffuses the light and reduces internal losses. 5. A micro prismatic sheet that controls the spreading angle of the light and reduces shadows and glare. 6. An array of the latest most efficient...

 Open the catalog to page 11
D-TEC Lighitng Handbook-12

A lighting checklist for your workplace Choose light sources that let you avoid flickering, glare and shadows. Be kind to your eyes by choosing a set-up that provide you with a low contrast between your light sources to reduce eye strain and fatigue. If you want to increase the luminous flux further, you can paint the walls and the ceilings in light colours. Choose light sources with low thermal heating and no acoustic noise. Choose light sources that have correct colour rendering, especially if your work within dentistry, beauty or dermatology. If necessary, whitewash or shade windows and skylights...

 Open the catalog to page 12

Archived catalogs

  1. Clair

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.