Incutest
2Pages

{{requestButtons}}

Catalog excerpts

Incutest - 1

I n f a n t I n c u b a t o r & R a d i a n t War m e r Tes t i n g S ys t e m first infant incubator and infant radiant warmer testing system meeting the requirements of the IEC Standards for incubators (IEC 60601-2-19) and radiant warmers (IEC 60601-2-21). With Datrend’s unique wireless display and control capabilities, sensing is done in the device under test, and the results are viewed externally in real-time on the color graphics display (Netbook PC included). Changes to the test protocol can be made without disturbing the heating environment. ■ Compatible with closed, forced air convection incubators, and open, radiant infant warmers ■ Simultaneous measurement of humidity, airflow, most precious resource sound, and 5 different temperatures ■ The only Tester available to test in compliance with IEC 60101-2-19 and IEC 60601-2-21 in life — the beginning of a new life itself! ■ All sensors independently movable to be placed in positions required by the Standard ■ Sound level measurements may be taken outside of incubator for external alarm test ■ Netbook PC controls system wirelessly, external to incubator ■ Optional precision controlled heater permits testing of body temperature sensor accuracy Incutest System Accur acy M att er s • www.datr end.com Datrend Systems Inc. introduces Incutest, the

Open the catalog to page 1
Incutest - 2

Incutest – Performance Specifications Temperature: Measurement Range: 0 deg C to 50 deg C Accuracy: T1+/- 0.05 deg C Resolution: 0.01 deg C Convection: 5 “puck” sensors (T1-T5) - radiant warmer Air Convection: 5 sensors (alternate “pos”’ T1 - T5) - incubator Skin Sensor2: Sensor “oven” with thermal pad contact 28 deg C to 40 deg C in 2 deg C increments Resolution: 0.01 deg C Accuracy: +/- 0.05 deg C Airflow: Measurement Range: 0.1 to 1 m/s Accuracy: +/- 0.1 m/s at 50% RH +/- 15% Sound Level: Measurement Range: 30 dbA to 90 dbA, Type III Accuracy: +/- 3 dbA Resolution: 0.1 dbA Relative...

Open the catalog to page 2

All Datrend Systems catalogs and technical brochures

  1. vPad-O2

    106 Pages

  2. venTest

    2 Pages

  3. vPad-BPTM

    1 Pages

  4. vPad-Mini

    2 Pages

  5. vPad-ES2

    2 Pages

  6. vPad-Rugged2

    2 Pages

  7. vPad-RF

    2 Pages

  8. vPad-A1

    2 Pages

  9. vPad-IN

    2 Pages

  10. Model 20A

    1 Pages

  11. FMS-3

    2 Pages

  12. AMPS-1

    2 Pages

  13. Phase 3 VLM

    2 Pages

  14. Phase 3

    2 Pages

  15. ES601 Plus

    2 Pages

Archived catalogs

  1. vPAD RF

    2 Pages

  2. MPS-2

    2 Pages

  3. vPad-353

    2 Pages

  4. vPad-ES

    2 Pages