Infutest 2000 RSM
2Pages

{{requestButtons}}

Catalog excerpts

Infutest 2000 RSM - 1

Infutest 2000 Series E P r eci s i on I n f u s io n D ev ic e An a l yz e r pumps or four independent channels of a multichannel device in just seconds with our Infutest 2000 Series E and optional RSM. Infutest 2000 Series E is the solution for your device inspection requirements. Conduct the full range of flow, pressure, volume and interval tests on practically any fluid delivery system including single rate, dual rate and patient controlled analgesia (PCA) devices. These tests are performed following easy-to-use manual or autosequence formats using the front panel keypad and graphical display. Additionally, via the standard serial port, interface the analyzer to our ES601Plus Automated Safety Analyzer or other test systems such as a medTester 5000C with IVPUMP autosequence option, or to a PC running our Data Transfer Program (DTP), a standard accessory, for automated operation and test data storage. End-of-Infusion Analysis — Accurate volume-to-be-infused (VTBI) measurements are a snap with Infutest 2000 Series E. End-of-infusion analysis (EIA) calculates the volume infused at the instant the STOP key is pressed or when the autosequence preset test time has elapsed. This computation can be easily verified by checking the full test data log from Infutest 2000 Series E internal memory. SynchroStart — SynchroStart accurately captures the initial start-up flow dynamics of your IVpump, an invaluable feature when testing pumps with a pulsatile flow pattern. No need toattempt to start both the IV pump and the analyzer at the same time to make this critical measurement — Infutest 2000 does it for you... Automatically! Expand to Four Channels with our Optional Remote Sensor Module Remote Sensor Module Accur acy M att er s • www.datr end.com Simultaneously inspect up to four single chann

Open the catalog to page 1
Infutest 2000 RSM - 2

Infutest 2000 Series E – Performance Specifications Single Rate Test (Continuous Flow Conditions) Flow Measurement Nominal range: 0.1 - 1200 ml/hr Max. flow measurable and displayed: 1700 ml/hr Min. flow measurable and displayed: 0.04 ml/hr Max. display resolution: 0.001 ml/hr Measuring time: 10 min. at 0.1 ml/hr / 20 sec. max. above 6 ml/hr Accuracy: Average flow: +/- 1%, 0.1- 1200 ml/hr Ranges: LOW - 0.1 to 170 ml/h / HIGH - 170 to 1200 ml/h Range selection: Automatic Internal nominal effective collection volume: LOW range: 0.014 ml HIGH range: 1.1 ml Volume Measurement Range: 0 - 9999...

Open the catalog to page 2

All Datrend Systems catalogs and technical brochures

  1. vPad-O2

    106 Pages

  2. venTest

    2 Pages

  3. vPad-BPTM

    1 Pages

  4. vPad-Mini

    2 Pages

  5. vPad-ES2

    2 Pages

  6. vPad-Rugged2

    2 Pages

  7. vPad-RF

    2 Pages

  8. vPad-A1

    2 Pages

  9. vPad-IN

    2 Pages

  10. Model 20A

    1 Pages

  11. FMS-3

    2 Pages

  12. AMPS-1

    2 Pages

  13. Phase 3 VLM

    2 Pages

  14. Phase 3

    2 Pages

  15. ES601 Plus

    2 Pages

Archived catalogs

  1. vPAD RF

    2 Pages

  2. MPS-2

    2 Pages

  3. Incutest

    2 Pages

  4. vPad-353

    2 Pages

  5. vPad-ES

    2 Pages