Phase 3 VLM

Phase 3 VLM

Phase 3 VLM

Product catalog summary
Overview: The Phase 3 Defibrillator/Pacer Analyzer is a versatile and portable device designed to test various types of defibrillators and transcutaneous pacers with high accuracy. It supports monophasic, biphasic, and pulsed multiphasic defibrillators, as well as AEDs, with better than 1% accuracy.
Key Features:
  • Portability: Includes a detachable paddle plate for hands-free testing and a battery that allows up to 24 hours of continuous operation.
  • USB Connectivity: Enables real-time waveform capture and efficient data transfer to a PC.
  • Test Record Storage: Can store up to 50 test records and 10 defibrillator discharge waveforms.
  • Variable Load Module (VLM): Allows testing at maximum energy with selectable loads from 25 to 175 ohms, compliant with AAMI DF-80 and IEC 60601-2-4 standards.
  • Phase 3pc Software: Facilitates the creation and editing of autosequences and data storage on a PC.
Performance Specifications:
  • Tests Performed: Includes defibrillator energy, charge time, cardioversion, AED performance, ECG monitor performance, pacer sensitivity, refractory periods, and noise immunity.
  • Energy Measurement: High range up to 600 Joules and low range up to 50 Joules with ±1% accuracy.
  • Voltage and Current Measurement: High range up to 5000 Volts and 100 Amps; low range up to 1000 Volts and 20 Amps.
  • Pacemaker Tests: Includes pulse amplitude, rate, width, noise immunity, sensitivity, and refractory period tests.
  • ECG Simulator: Provides various test waveforms including normal sinus rhythm and arrhythmia simulations.
Interface and Connectivity:
  • Display: LCD with 240 x 64 pixel graphics.
  • Inputs/Outputs: Includes defibrillator and pacemaker inputs, ECG simulator outputs, and waveform outputs.
  • Ports: USB, RS-232, and keyboard ports for connectivity.
Environmental and Physical Specifications:
  • Operating Environment: 15°C to 40°C, 10% to 90% RH, indoor use only.
  • Dimensions and Weight: 9.5" W x 8" H x 5.5" D, weighing 3 lbs (1.4 kg).
Note: All specifications are subject to change without notice. © DATREND SYSTEMS INC. JULY 2014
See more

Catalog excerpts

Phase 3 VLM-1

D ef i b r i l l at o r / Tr an s c u t a n e o us P a c e r An a l yz e r specifically designed to test Pulsed Multiphasic defibrillators. Versatility – Phase 3 tests Monophasic, Biphasic and Pulsed Multiphasic Defibrillators, AEDs and Transcutaneous Pacers with better than 1% accuracy on either line or battery power. Portability – Detachable Paddle Plate provides easy hands-free testing. Battery provides up to 24 hours of continuous operation. USB Connectivity – USB Communication capability allows real-time waveform capture and efficient data transfer to your PC. Real-Time Wave Capture – Capture high-resolution signal data to a PC running Phase3pc software immediately after discharge. Test Record Storage – Phase 3 provides storage for up to 50 Test Records and up to 10 defibrillator discharge waveforms as Wave Records. Variable Load Module – Our optional, exclusive VLM allows testing defibrillators at maximum energy with selectable loads from 25 to 175 ohms, in accordance with AAMI DF-80 and IEC 60601-2-4. High-resolution wave graphics and test data are obtained with Phase 3VL software — a standard accessory to the VLM. Phase 3pc Companion Software – Included as a standard accessory, Phase 3pc allows you to create and edit autosequences, download and store test data and wave graphics to your PC. Variable Load Module Accur acy M att er s • www.datr end.com Phase 3 is the first Defibrillator / Pacer Analyzer

 Open the catalog to page 1
Phase 3 VLM-2

Phase 3 – Performance Specifications Tests Performed Defibrillator Energy, Charge Time and Cardioversion Automated External Defibrillator (AED) Performance ECG Monitor Performance Pacer Sensitivity, Refractory Periods and Noise Immunity Pacer Pulse Characteristics Energy Measurement, General Load resistance: 50 ohms ±1%, non-inductive ECG amplitude at defib pads: 1 mV QRS WAVEFORM (oscilloscope) Output High Range: 1000:1 amplitude attenuation Low Range: 200:1 amplitude attenuation Waveform Playback: 200: 1 time base expansion First Phase Pulse Width: 0.1 - 58 msec Second Phase Pulse Width 0.1...

 Open the catalog to page 2

All Datrend Systems catalogs and technical brochures

  1. vPad-O2

    106  Pages

  2. venTest

    2  Pages

  3. vPad-BP

    1  Page

  4. vPad-Mini

    2  Pages

  5. vPad-ES2

    2  Pages

  6. vPad-Rugged2

    2  Pages

  7. Infutest Solo

    2  Pages

  8. vPad-RF

    2  Pages

  9. vPad-A1

    2  Pages

  10. vPad-IN

    2  Pages

  11. Model 20A

    1  Page

  12. FMS-3

    2  Pages

  13. AMPS-1

    2  Pages

  14. Oxitest Plus7

    2  Pages

  15. Phase 3

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.