The MPTS Sampling Device is designed for the safe and efficient sampling of toxic, radioactive, or explosive powders. It ensures representative samples without mechanical parts, making it easy to clean and maintain.

Specifications
  • Constructed from AISI type 316L stainless steel, electro-polished.
  • Available sampling volumes: 50 or 100 ml.
  • Compatible with 250 or 1000 ml bottles.

Features
  • Provides homogeneous and representative samples.
  • Fast sampling to accurately reflect the degree of mixture, humidity, and homogeneity.
  • Online sampling capability.
  • No mechanical parts, preventing particle attrition or segregation.
  • Full emptying of the sampling line after each cycle.
  • Conveyance with inert gas to avoid oxidation.
  • Compliant with GMP and ATEX standards.
  • Suitable for equipment with low accessibility.
  • Easy to clean with a CIP system.

Options
  • Various sampling volumes and materials available.
  • Hygienic, sterile, and portable unit options.
  • Designs according to containment level.

Applications
The device is ideal for integration into processes involving dryers, mixers, and packaging units, especially where safety concerns restrict personnel access. It can be integrated into glove boxes or other containment systems, ensuring full containment and sample integrity.
See more

Catalog excerpts

MPTS Sampling Device-1

Powder Handling Excellence MPTS Sampling Device · Safe sampling of toxic or explosive powders · Representative samples · Variable sample quantities · No mechanical parts · Easy to clean · Contained · Automatic

 Open the catalog to page 1
MPTS Sampling Device-2

The MPTS* facilitates complex sampling procedures directly from equipment, such as dryers, mixers, packaging units, etc. Features · Homogeneous representative samples The sampling procedure is simplified, whether from equipment with poor access, or where, for safety reasons, personnel are not admitted. The sample is taken in a few seconds, thus giving an instant image of the condition of the powder during the process (degree of mixture, humidity, homogeneity). It is extracted and transferred to its final destination whilst maintaining full containment, remaining homogeneous and representative...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.