Lifeline AED - 1

Defibrillation/Monitoring Pads Battery Pack Self Tests “Typical, with new battery at 25° C Patient Analysis System Event Documentation TYPE Semi-automatic external defibrillator MODEL DDU-100A, DDU-100E WAVEFORM Biphasic Truncated Exponential (Impedance compensated) ENERGY Adult: 150 Joules Pediatric: 50 Joules (Nominal into 50 Ohm load) CHARGE TIME** DBP-2800: Less than 6 seconds DBP-1400: Less than 9 seconds PATIENT ANALYSIS Automatically evaluates patient impedance for proper pad contact. Monitors signal quality and analyzes patient ECG for shockable/ non-shockable rhythms TYPE Lithium/Manganese Dioxide Disposable, recyclable, non-rechargeable VOICE PROMPTS Extensive voice prompts guide user through operation of the unit and CPR CPR PACING Metronome CONTROLS Lighted On/Off button Lighted Shock button INDICATORS ■ "check pads" ■ "do not touch patient" ■ "analyzing" ■ AED Status LED SENSITIVITY/SPECIFICITY Meets AAMI-DF-39 specifications and AHA recommendations LOW BATTERY INDICATORS Visible Audible “Typical, with new battery at 25° C MODEL Adult - DDP-100 Child/Infant - DDP-200P TYPE Pre-connected, single-use, non-polarized, disposable, self-adhesive electrodes with cable and connector INTERNAL EVENT RECORD Critical ECG segments and rescue event parameters are recorded and can be downloaded to a removable data card PC-BASED EVENT REVIEW ECG with event tag display, and audio playback when available TEMPERATURE Operating: 0 to 50°C (32 to 122°F) Standby (with battery installed): 0 to 50°C (32 to 122°F) RELATIVE HUMIDITY Operating / Standby: 5% - 95% (non-condensing) ALTITUDE -500 to 15,000 ft (-150 to 4500 m) per MIL-STD-810F 500.4 Procedure II VIBRATION Ground (MIL-STD-810F 514.5 Category 20) Helicopter (RTCA/DO-160D, Section 8.8.2, Cat R, Zone 2, Curve G) Jet Aircraft (RTCA/DO-160D, Section 8, Cat H, Zone 2, Curves B & R) SURFACE AREA 103 cm2 (nominal, each pad) 50 cm2 (nominal, each pad) PAD PLACEMENT Adult - Anterior/Anterior Child/Infant - Anterior/Posterior CABLE LENGTH (typical) 48 in (122 cm) REMOVABLE STORAGE (optional) Up to 12 hours of ECG and event data storage (no audio option) or up to 2 hours of audio, ECG and event storage (audio option) on a removable data card. Actual length of storage is dependent on card capacity SHOCK/DROP ABUSE TOLERANCE MIL-STD-810F 516.5 Procedure IV (1 meter, any edge, corner, or surface, in standby mode) SEALING/WATER RESISTANCE IEC60529 class IP54; Splash Proof, Dust Protected (Battery Pack installed) ESD EN 61000-4-2:2009 (open air up to 15kV or direct contact up to 8kV) EMC (Emission) EN 60601-1-2:2001 +A1:2006, limits EN 55011:1998 +A1:1999 +A2:2002 Group 1 Level B, method EMC (Immunity) EN 60601-2-4:2003, limits EN 61000-4-3:2002 Level 3 (10V/m), method AUTOMATIC Automatic daily, weekly, monthly and quarterly circuitry tests BATTERY INSERTION System integrity test on battery insertion PAD PRESENCE Pads preconnected tested daily USER-INITIATED Unit and battery pack system test may also be initiated by the user STATUS INDICATION Visual and audible indication of unit status *Specifications subject to change without notice v defib ech Life-Saving Technology Within Reach Physical SIZE 8.5 x 11.8 x 2.7 inches (22 x 30 x 7 cm) WEIGHT (Approximate) With DBP-1400: 4.2 lbs (1.9 kg) With DBP-2800: 4.4 lbs (2.0 kg) Defibtech, LLC • Guilford, CT 06437 1-203-453-4507 1-866-DEFIB-4U (866-333-4248) • www.defibtech.com ELECTRONIC DISTRIBUTION

Open the catalog to page 1

All Defibtech catalogs and technical brochures

  1. Lifeline ARM

    2 Pages