video corpo

Lifeline ARM TECHNICAL SPECIFICATIONS†
1Pages

{{requestButtons}}

Catalog excerpts

Lifeline ARM TECHNICAL SPECIFICATIONS† - 1

ENVIRONMENTAL COMPRESSION MODES Continuous Compressions; Compressions with Breathing (30:2, 30 compressions with 3-second pause for ventilation) factory default; future protocols via field updates SIZE (assembled) 23.5 x 20.75 x 9 inches (59.7 x 52.7 x 22.9 cm) SIZE (in carrying case) 24 x 18 x 10 inches (61.0 x 45.7 x 25.4 cm) WEIGHT (with battery pack) 15.9 lbs (7.1 kg) MODEL NUMBER RPM-1000 RATED OUTPUT 24.0VDC (±5%) tSpecifications subject to change without notice BATTERY PACK COMPRESSION DEPTH 2.1 inches ±0.1 inches (5.3 cm ±0.3 cm) from start position (nominal patient) COMPRESSION FREQUENCY 101 ±1 compressions per minute COMPRESSION DUTY CYCLE 50% ±5% ADULT PATIENT RANGES Adult patients that fit into the ACC: Chest width -18 inches (45.7 cm) max Chest height -6.5 to 11.8 inches (16.5 to 30 cm) Use of the RMU-1000 is not restricted by patient weight INPUT VOLTAGE 100 - 240VAC, 50/60Hz nominal INPUT CURRENT <2.3A OPERATING / MAINTENANCE TEMPERATURE 0 to 40°C (32 to 104°F) STANDBY / STORAGE / TRANSPORT TEMPERATURE -20 to 70°C (-4 to 158°F) HUMIDITY 5% to 95% (non-condensing) VIBRATION MIL-STD-810G 514.6 Category 20 (Ground) SEALING / WATER RESISTANCE IEC 60529 class IP43 (battery pack installed) DEVICE CLASSIFICATION Internally powered Class II (with external power source) MODEL NUMBER RBP-1000 BATTERY TYPE 18.5V, 5300 mAh, Lithium-ion. Rechargeable, recyclable. OPERATION TIME 1 hour (nominal patient)* BATTERY PACK CHARGE TIME Less than 3 hours in ACC* Less than 2 hours if charging one battery pack in optional external battery pack charging station (less than 3 hours if charging two battery packs)* BATTERY PACK USEFUL LIFE Recommended to replace battery pack every 3 years or if battery pack indicator displays a replace battery pack condition (~300 charge/ discharge cycles**) ELECTROMAGNETIC COMPATIBILITY (EMISSIONS & IMMUNITY) • IEC/EN 60601-1-2:2014 • RTCA/DO-160G Environmental Conditions and Test Procedures for Airborne Equipment, Sections 20 and 21 » Radiated susceptibility (category S, T) » Radiated emissions (category M, L) » Conducted emissions (category L, M, and H) DESIGN STANDARDS Meets applicable requirements of: • IEC 60601-1 • UL 60601-1 • CAN/CSA C22.2 60601-1 • IEC 60601-1-2 BATTERY PACK OPERATING TEMPERATURE 0 to 40°C (32 to 104°F) ambient CHARGING TEMPERATURE 0 to 40°C (32 to 104°F) ambient STORAGE TEMPERATURE 0 to 40°C (32 to 104°F); -20 to 60°C (-4 to 140°F) short-term <1 month SEALING / WATER RESISTANCE IEC 60529 class IP44 *typical, with new battery at 25°C **one charge/discharge cycle is defined as charging and discharging the full capacity of the battery pack Life-Saving Technology Withri Reach Defibtech, LLC • Guilford, CT 06437 USA • 1-203-453-4507 • 1-866-DEFIB-4U (1-866-333-4248) www.defibtech.com ELECTRONIC DISTRIBUTION THIS DOCUMENT FOR INTERNATIONAL DISTR

Open the catalog to page 1

All Defibtech catalogs and technical brochures

  1. Lifeline AED

    1 Pages

  2. Lifeline ARM

    2 Pages