Introduction
The document discusses the use of CO2 laser technology for stimulating Laser Evoked Potentials (LEPs) in neurophysiology. This technology has transformed the study of pain by selectively activating nociceptors without affecting non-nociceptive afferents, which is a limitation of electrical stimuli.

Specifications and Advantages
The CO2 laser stimulator is compact, practical, and easy to use, providing quick assessments of the nociceptive system. It is widely used in clinical neurophysiology for various pain assessments. The YAP laser allows for easy stimulation of different body areas and can be used in shielded environments like MRI and MEG rooms.

Neurolas System
The Neurolas system uses an articulated arm with high mechanical accuracy to deliver CO2 laser radiation. It allows for adjustments in stimulus amplitude, duration, and energy density. The system is compatible with electromyographs and controlled by a microprocessor, ensuring high repeatability and minimal latency.

Clinical Applications
LEPs are useful in diagnosing and assessing various pain syndromes, including neuropathic pain, trigeminal neuralgia, and fibromyalgia. The technology is considered reliable for assessing the nociceptive pathway from skin to cerebral cortex.

Technical Data
The document provides technical specifications for the laser systems, including wavelength, peak power, pulse length, and transmission systems. The CO2 laser operates at 1064nm with a maximum power of 15W, while the ND:Yap laser operates at 1340nm with a peak power of 750W.

Safety and Standards
The laser devices are classified as Class 4, with safety measures to avoid direct or diffuse exposure to laser radiation. They comply with EN 60825-1 standards and are manufactured under ISO 9001 and ISO 13485 quality assurance systems.

Conclusion
DEKA, a leader in laser technology, manufactures these devices, ensuring quality and innovation in the medical field. The CO2 laser technology for LEPs offers a significant advancement in pain study and management.
See more

Catalog excerpts

Stimul 1340 Neurolas-1

CO2 LASER TECHNOLOGY FOR stimulation OF LEPs (Laser Evoked Potentials)

 Open the catalog to page 1
Stimul 1340 Neurolas-2

Stimul 1 340 CO2 LASER TECHNOLOGY FOR stimulation OF LEPs (Laser Evoked Potentials) Stimul 1340 The introduction of laser stimulators in basic and clinical neurophysiology has revolutionized the approach to study pain in humans. Because large-diameter fibers have a lower electrical threshold than the small nerve fibers that convey pain sensations, electrical stimuli, even noxious, also excite large, nonnociceptive afferents, thus inhibiting nociceptive transmission or hindering nociceptive signals. Hence the need for a selective activation of nociceptors. Although several methods of heating the...

 Open the catalog to page 2
Stimul 1340 Neurolas-3

Neurolas Neurolas is a CO2 laser system used in neurophysiology for studying evoked potentials. The stimulus generated by Neurolas excites the thermal-mechanical nociceptors provoking cerebral potentials and in this way allowing to detect the dysfunctions in the behaviour of the afferent fibres. Neurolas offers the chance to adjust the amplitude and/or the duration of the stimulus as well as varying the energy density of the laser emission in an ongoing manner by acting on the stimulation area. Other advantages of this laser include the high repeatability of the impulses, the totally negligible...

 Open the catalog to page 3
Stimul 1340 Neurolas-4

Stimul 1 340 CO2 LASER TECHNOLOGY FOR stimulation OF LEPs (Laser Evoked Potentials) Laser type Peak Power Pulse lenght Pulse Energy Transmissione System 550μm Optical fiber 10m Long Aiming Beam System Control Power supply 0459 RADIAZIONE LASER VISIBILE E INVISIBILE EVITARE L'ESPOSIZIONE DELL'OCCHIO O DELLA PELLE ALLA RADIAZIONE DIRETTA O DIFFUSA APPARECCHIO LASE DI CLASSE 4 Max. energia laser Er:YAG 700mJ @ 2940 nm Max. durata impulso 450µs Classificato secondo EN 60825-1 (2003-02) RADIAZIONE LASER VISIBILE E INVISIBILE EVITARE L'ESPOSIZIONE DELL'OCCHIO O DELLA PELLE ALLA RADIAZIONE DIRETTA O...

 Open the catalog to page 4

Archived catalogs

  1. Monalisa Touch

    12  Pages

  2. RedTouch

    12  Pages

  3. AGAIN PRO EN

    12  Pages

  4. SCHWARZY EN

    12  Pages

  5. coolwaves

    4  Pages

  6. EXCILITE-µ

    6  Pages

  7. Synchro HP

    2  Pages

  8. Luxea ENGLISH

    16  Pages

  9. Synchro QS4

    6  Pages

  10. Smarty A10

    4  Pages

  11. Smartfile

    4  Pages

  12. SMART 980_5

    2  Pages

  13. Smartepil LS

    4  Pages

  14. SmartXIDE HS

    8  Pages

  15. ONDA

    8  Pages

  16. ONDA PRO - ENG

    12  Pages

  17. Motus LD

    6  Pages

  18. Motus AY

    6  Pages

  19. DenaVe

    8  Pages

  20. TriActive +

    8  Pages

  21. SmartXide2

    8  Pages

  22. Syncro HP

    6  Pages

  23. All System

    15  Pages

  24. SmartLite

    4  Pages

  25. Smart US_20D

    4  Pages

  26. Synchro VasQ

    6  Pages

  27. Synchro FT

    6  Pages

  28. Stimul1340

    4  Pages

  29. Stimul 1340

    4  Pages

  30. Syncro FT

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.