Catalog excerpts

//eroDR Family Distributed by : KONICA MINOLTA WIRELESS DIGITAL RADIOGRAPHY SYSTEM KONICA MINOLTA, INC. 1 Sakura-machi, Hino-shi, Tokyo, 191-8511, Japan Giving Shape to Ideas
Open the catalog to page 1
mage Quality Scintillator technology AeroDR offers a "needle crystal" Csl scintillator developed and manufactured by KonicaMinolta. The "needle crystal" Csl scintillator is a proprietary method to apply Csl developed through research and manufacturing experience to deliver high DQE11. • Schematic diagram of scintillator and TFT-panel. The optimal combination of the AeroDR detector using a KonicaMinolta Csl scintillator combined with the newly developed low noise readout ICs deliver high DQE11. 1 Detective Quantum Efficiency
Open the catalog to page 2
Performance model AeroDR 1417HQ • Light weight at 2.9kg (6.41b) • 211 images/5.8 hours*2 • Available for AeroSync Value model AeroDR 1417S • Light weight at 2.8kg (6.21b) • 211 images/5.8 hours*2 Performance model AeroDR 1012HQ • Super light weight at 1.7kg (3.8 lb) • High image quality at lower X-ray dose compared to CR. • 146 images/4.0 hours*2 • Available for AeroSync Performance model • Light weight at 3.6kg (7.91b) • 189 images/5.2 hours*2 • Available for AeroSync @ Light weight of panel 'O' No need to detach cassette DR battery O' High durability for handling DR panel same as CR...
Open the catalog to page 3
KonicaMinolta has reviewed SYSTEM 2 seriesthe current AeroDR product features and developed new models. PREMIUM model Rapid cycle time •Top model of AeroDR series. • Super light weight at 2.6kg (5.7 lb) • Rapid cycle time of 6 sec. in wireless operation • Long operating time of 300 images/8.2hours*2 •AeroSync is available The AeroDR 2 1417 series introduces rapid cycle time, reducing the time needed for image processing to six seconds to improve comfort while increasing productivity. • Rapid cycle time (Console: CS-7) Value model • New value model with added values. • Super light weight at...
Open the catalog to page 4
Its sophisticated functions will enrich your daily workflow of examination. magePilot ImagePilot provides you with simple workflow by Integral-processing. And by using its image archiving and viewing functions you can also use it as a small PACS. Integrated control station CS-7 Tube and gauze image enhancement CS-7 can control AeroDR detectors and connect to CR readers.*7 CS-7 can highlight tube and gauze images that are difficult to be detected with normal images. ^ Optional license is necessary to use this function ImagePilot mobile client solution *7 Please contact your KonicaMinolta...
Open the catalog to page 5
■ X-ray auto detection mode “AeroSync” AeroSync®, a new X-ray exposure synchronization technology, requires no cable connections to the x-ray generator. Image capture automatically begins when the AeroDR senses the X-ray exposure. Existing CR or analogue systems can be converted to DR systems by AeroSync easily without connecting to an X-ray system. X-ray photons • In-room solution One of KonicaMinolta proposals for an in-room solution is to retrofit DR systems which can utilize existing X-ray systems. We can provide high image quality, rapid cycle time and eliminate handling CR cassettes....
Open the catalog to page 6
Soecifications AeroDR Detector (AeroDR SYSTEM) AeroDR Detector (AeroDR SYSTEM 2) Model name Detection method Scintillator External dimensions (WxDxH) / Weight AeroDR P-ll(AeroDR 1417HQ)/AeroDR P-12(AeroDR 1417S)/AeroDR P-21 (AeroDR 1717HQ) AeroDR P-31 (AeroDR 1012HQ) Indirect conversion method Pixel size Image area size AD conversion Usable grid frequency Durability*10 Communication W-LAN encryption Cycle time*12 16 bit (65,536 gradients) 40Ip/cm, 34lp/cm Point load: 15Okg@04Omm, Face load: 300kg@ effective image area overall Dedicated wired Ethernet connection/ Wireless LAN (IEEE802.11a...
Open the catalog to page 7
External dimensions (WxDxH) Amount of connectable AeroDR Detectors Power requirements Power consumption External dimensions (WxDxH) Weight Wired connection : Up to 2 Wireless connection : Up to 4 AeroDR Access Point is necessary when operating wireless. With the AeroDR Detector connected : Approx.l60VA (100-240 V) Without the AeroDR Detector connected : Approx. 33VA (100-240 V) 460x180x285mm (18.1x7.1 x 11.2 inch)_ image processing Auto-gradation processing. Frequency processing (F processing), Equalization processing (E processing), Hybrid processing (HF processing - HE processing),...
Open the catalog to page 8All DEL Medical catalogs and technical brochures
-
Konica Model 110
4 Pages
-
FujiFilm Prima T2
2 Pages
-
Vieworks DR
8 Pages
-
Konica Aero DR
8 Pages
-
FujiFilm FDR ES
4 Pages
-
DELWORKS EDR
8 Pages
-
Universal Veterinary
4 Pages
-
Universal Chiropractic
4 Pages
-
Vision R
12 Pages
-
Apollo Vision
9 Pages
-
Apollo
12 Pages
-
Apollo EZ/DRF
16 Pages
-
Apollo EZ
12 Pages
-
Apollo DRF
16 Pages
-
Straight Arm
2 Pages
-
UARM
5 Pages
-
FMT18M
10 Pages
-
FMT18T
10 Pages
-
OTC18M
10 Pages
-
OTC18T
10 Pages
-
MDR
8 Pages
-
FMT
2 Pages
-
RT100
2 Pages
-
MT500
2 Pages
-
Vt 300
2 Pages
-
FujiFilm FDX Console
8 Pages
-
FujiFilm FCRView
4 Pages
-
FujiFilm FCR Prima T2
2 Pages
-
DFMT
2 Pages
-
DFMTP
2 Pages
-
OTC15T
2 Pages
-
DEL MEDICAL DFMTPS
10 Pages
-
OTC15T System
14 Pages
-
Del Medical Anthem
2 Pages
-
Del Medical CM Series DR
2 Pages
-
Del Medical CM Series
2 Pages
-
Del Medical IN Series
2 Pages
-
Universal Anthem
2 Pages
-
Universal HE425
2 Pages
-
FujiFilm Film Blue Super RX
2 Pages
-
DEL MEDICAL EV800
2 Pages
-
DEL MEDICAL U-ARM
5 Pages
-
DEL MEDICAL DFMT
6 Pages
-
OTC12S
4 Pages
-
DEL MEDICAL OTC15T
7 Pages
-
Del Medical OTC12D
4 Pages
-
Del Medical OTC12D (2014)
2 Pages
-
Del Medical FWFC
2 Pages
-
Del Medical DFMT/FMT
4 Pages
-
Del Medical DFMTPS
2 Pages