Konica Aero DR
8Pages

{{requestButtons}}

Catalog excerpts

Konica Aero DR - 1

//eroDR Family Distributed by : KONICA MINOLTA WIRELESS DIGITAL RADIOGRAPHY SYSTEM KONICA MINOLTA, INC. 1 Sakura-machi, Hino-shi, Tokyo, 191-8511, Japan Giving Shape to Ideas

Open the catalog to page 1
Konica Aero DR - 2

mage Quality Scintillator technology AeroDR offers a "needle crystal" Csl scintillator developed and manufactured by KonicaMinolta. The "needle crystal" Csl scintillator is a proprietary method to apply Csl developed through research and manufacturing experience to deliver high DQE11. • Schematic diagram of scintillator and TFT-panel. The optimal combination of the AeroDR detector using a KonicaMinolta Csl scintillator combined with the newly developed low noise readout ICs deliver high DQE11. 1 Detective Quantum Efficiency

Open the catalog to page 2
Konica Aero DR - 3

Performance model AeroDR 1417HQ • Light weight at 2.9kg (6.41b) • 211 images/5.8 hours*2 • Available for AeroSync Value model AeroDR 1417S • Light weight at 2.8kg (6.21b) • 211 images/5.8 hours*2 Performance model AeroDR 1012HQ • Super light weight at 1.7kg (3.8 lb) • High image quality at lower X-ray dose compared to CR. • 146 images/4.0 hours*2 • Available for AeroSync Performance model • Light weight at 3.6kg (7.91b) • 189 images/5.2 hours*2 • Available for AeroSync @ Light weight of panel 'O' No need to detach cassette DR battery O' High durability for handling DR panel same as CR...

Open the catalog to page 3
Konica Aero DR - 4

KonicaMinolta has reviewed SYSTEM 2 seriesthe current AeroDR product features and developed new models. PREMIUM model Rapid cycle time •Top model of AeroDR series. • Super light weight at 2.6kg (5.7 lb) • Rapid cycle time of 6 sec. in wireless operation • Long operating time of 300 images/8.2hours*2 •AeroSync is available The AeroDR 2 1417 series introduces rapid cycle time, reducing the time needed for image processing to six seconds to improve comfort while increasing productivity. • Rapid cycle time (Console: CS-7) Value model • New value model with added values. • Super light weight at...

Open the catalog to page 4
Konica Aero DR - 5

Its sophisticated functions will enrich your daily workflow of examination. magePilot ImagePilot provides you with simple workflow by Integral-processing. And by using its image archiving and viewing functions you can also use it as a small PACS. Integrated control station CS-7 Tube and gauze image enhancement CS-7 can control AeroDR detectors and connect to CR readers.*7 CS-7 can highlight tube and gauze images that are difficult to be detected with normal images. ^ Optional license is necessary to use this function ImagePilot mobile client solution *7 Please contact your KonicaMinolta...

Open the catalog to page 5
Konica Aero DR - 6

■ X-ray auto detection mode “AeroSync” AeroSync®, a new X-ray exposure synchronization technology, requires no cable connections to the x-ray generator. Image capture automatically begins when the AeroDR senses the X-ray exposure. Existing CR or analogue systems can be converted to DR systems by AeroSync easily without connecting to an X-ray system. X-ray photons • In-room solution One of KonicaMinolta proposals for an in-room solution is to retrofit DR systems which can utilize existing X-ray systems. We can provide high image quality, rapid cycle time and eliminate handling CR cassettes....

Open the catalog to page 6
Konica Aero DR - 7

Soecifications AeroDR Detector (AeroDR SYSTEM) AeroDR Detector (AeroDR SYSTEM 2) Model name Detection method Scintillator External dimensions (WxDxH) / Weight AeroDR P-ll(AeroDR 1417HQ)/AeroDR P-12(AeroDR 1417S)/AeroDR P-21 (AeroDR 1717HQ) AeroDR P-31 (AeroDR 1012HQ) Indirect conversion method Pixel size Image area size AD conversion Usable grid frequency Durability*10 Communication W-LAN encryption Cycle time*12 16 bit (65,536 gradients) 40Ip/cm, 34lp/cm Point load: 15Okg@04Omm, Face load: 300kg@ effective image area overall Dedicated wired Ethernet connection/ Wireless LAN (IEEE802.11a...

Open the catalog to page 7
Konica Aero DR - 8

External dimensions (WxDxH) Amount of connectable AeroDR Detectors Power requirements Power consumption External dimensions (WxDxH) Weight Wired connection : Up to 2 Wireless connection : Up to 4 AeroDR Access Point is necessary when operating wireless. With the AeroDR Detector connected : Approx.l60VA (100-240 V) Without the AeroDR Detector connected : Approx. 33VA (100-240 V) 460x180x285mm (18.1x7.1 x 11.2 inch)_ image processing Auto-gradation processing. Frequency processing (F processing), Equalization processing (E processing), Hybrid processing (HF processing - HE processing),...

Open the catalog to page 8

All DEL Medical catalogs and technical brochures

  1. Vieworks DR

    8 Pages

  2. DELWORKS EDR

    8 Pages

  3. Vision R

    12 Pages

  4. Apollo

    12 Pages

  5. Apollo EZ/DRF

    16 Pages

  6. Apollo EZ

    12 Pages

  7. Apollo DRF

    16 Pages

  8. Straight Arm

    2 Pages

  9. UARM

    5 Pages

  10. FMT18M

    10 Pages

  11. FMT18T

    10 Pages

  12. OTC18M

    10 Pages

  13. OTC18T

    10 Pages

  14. MDR

    8 Pages

  15. FMT

    2 Pages

  16. RT100

    2 Pages

  17. MT500

    2 Pages

  18. Vt 300

    2 Pages

  19. DFMT

    2 Pages

  20. DFMTP

    2 Pages

  21. OTC15T

    2 Pages

  22. OTC15T System

    14 Pages

  23. OTC12S

    4 Pages