1. Catalogs
  2. Delft DI
  3. DelftDI Adora DR

DelftDI Adora DR

DelftDI Adora DR

DelftDI Adora DR

Product catalog summary
Overview: The DelftDI Adora DRi is an intelligent workflow solution designed for high-volume patient throughput in direct digital radiographic applications. It features full APR auto-positioning, smart handle motorized movement, and intuitive tube head control, all aimed at stress-free operation.
Key Features:
  • Up to 1000 auto-positions with zero manual handling.
  • Acquisition station with a large DICOM calibrated touchscreen display.
  • Integration with Canon NE acquisition software and generator.
  • Extensive portfolio of Canon CXDI Flat Panel Detectors with high resolution and sensitivity.
  • Sophisticated image processing for high diagnostic value.
Detector Specifications:
  • Models: CXDI-401C Compact, CXDI-701C Wireless, CXDI-801C Wireless, CXDI-401C Wireless.
  • Scintillator: CsI (Cesium Iodide).
  • Resolution: 4.0 lp/mm with a pixel size of 125 x 125 μm.
  • DQE: Greater than 70% with a fill factor of 87%.
  • Gray scale: 4096 gradations.
  • Image matrix size varies by model.
  • Weight and dimensions vary by model.
X-Ray Generator Specifications:
  • Type: Indico 100, 150 kV / 65kW with optional 80kW available.
  • KV range: 40 to 150 kV.
  • mA range: 10 to 800 mA (65 kW).
  • mAs range: 0.5 to max 1000 mAs.
  • Time range: 1.0 to 6300 ms.
  • Technique selection includes kV with AEC option, kV/mAs, and kV/mA/Time.
X-Ray Tube & Collimator Specifications:
  • 350 kHU high capacity with 0.6/1.0 focal spot.
  • Fully automatic, motorized collimator with manual override.
  • Spectral filtration options available.
Ceiling Stand Specifications:
  • Motorized vertical column up to 1600 mm.
  • Fully automatic positioning with 999 APRs.
  • Smart Handle with smooth power-assisted movements.
  • Various rotation capabilities for tube, detector, and ceiling unit.
Wall Stand Specifications:
  • Max patient load: 250kg evenly distributed.
  • Motorized vertical travel: 510 – 860mm.
  • Table top dimension: 2930mm x 700mm.
  • Manual floating longitudinal and transverse movements.
Contact Information: DelftDI, Wiltonstraat 41, 3905 KW Veenendaal, The Netherlands. Phone: +31 318 583 400, Email: [email protected], Website: www.delftdi.com
See more

Catalog excerpts

DelftDI Adora DR-1

DelftDI Adora DRi A unique solution suitable for a wide range of direct digital radiographic applications through one-touch, stress-free operation. Every element and functional aspect of DelftDI Adora has been designed with the daily needs of the clinical staff in mind. l Intelligent workflow for high volume patient throughput l Full APR auto-positioning – no manual handling l Up to 1000 auto-positions l Smart handle motorized movement, zero force l Intuitive tube head control l Acquisition station with large DICOM calibrated touchscreen display l Canon NE acquisition software with generator integration l Extensive portfolio of Canon CXDI Flat Panel Detectors l High resolution, 125µm pixel pitch l High sensitivity l Sophisticated Image processing for highest diagnostic value l Detector exchangeability between different DelftDI modalities

 Open the catalog to page 1
DelftDI Adora DR-2

Specifications Detector (depending on configuration) CXDI-401C Compact CXDI-701C Wireless Purpose General Radiography ï Scintillator CsI (Cesium Iodide) ï Effective imaging area 415 x 426 mm 350 x 426 mm Resolution 4.0 lp/mm ï DQE >70% ï Fill Factor 87% ï Gray scale 4096 gradations ï Pixel size 125 x 125 μm ï Image matrix size 3320 x 3408 pixels 2800 x 3408 pixels Dimensions Sensor ± 550 x 555 x 119 mm ± 384 x 460 x 15 mm Weight Sensor ± 20 kg ± 3.3 kg (incl. battery pack) Preview image access time ± 3 sec ± 1 sec Cycle time ± 15 sec ± 9 sec Grid Fixed grid (removable) Removable static CXDI-801C...

 Open the catalog to page 2

All Delft DI catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.