Alarm module
22Pages

{{requestButtons}}

Catalog excerpts

Alarm module - 1

Alarm module Moduli di allarme 2025M CSQ MCD Delta PS r l ViaThanasau,4 20088 Rosate [Ml] - ITALY www.deltap.it

Open the catalog to page 1
Alarm module - 2

2025M Delta PS.r.l export0deltap.it info0deLtap.it www.deLtap.it CCOCCCOCC GCGGGGGCC Moduli di allarme Alarm module 2025M delta P alarm series has been specifically projected to respect the requirements of the ISO 7396-1 and IEC60601-1-8 normatives during the monitoring of the medical gases pressure. Different types of modules are available like the central unit alarms, the reporting alarms and the line or floor alarms. All this modules with an additional internal board and combined with other modules can create control sytems on RS485 line. Depending on the display type, two models of...

Open the catalog to page 2
Alarm module - 3

TECHNICAL SHEET TS31 Delta PS.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M series Page 1 of 10 Technical Data ALARM FOR CENTRAL SUPPLY UNIT ft DESCRIPTION The alarm is conceived to monitor medical gases central supply units through pressure switches and electrical sensors. INPUTS electrical signals Polarized, only direct current Internal power supply 12 Vdc +/- 20% External power supply 9-24 Vdcm Unax 5 mA for each sensor OUTPUTS Cumulative Reporting signal back-up alarm Polarized voltage-free, only direct current Common positive configuration V(max): 24 Vdc, only...

Open the catalog to page 3
Alarm module - 4

TECHNICAL SHEET TS31 Delta P S.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M Series Page 2 of 10Technical Data REPORTING ALARM FOR CENTRAL SUPPLY UNITS COD. 3373B-2025M DESCRIPTION The reporting alarm is useful to report central supply units alarm's signals. This device can manage the following signals [up to 9): central supply unit with cylinders, air plant with compressors, vacuum plant, AGSS INPUTS Polarized, only direct current Internal power supply 12 Vdc +/-20% OUTPUTS Cumulative Reporting signal back-up alarm Polarized voltage-free, only direct current Common...

Open the catalog to page 4
Alarm module - 5

TECHNICAL SHEET TS31 Delta PS.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M Series Page 3 of 10 DESCRIPTION Department alarm is useful to monitor max and min pressure for second stage pressure regulators group or area valves service units group. It can monitor up to 4 gases + vacuum. INPUTS Polarized, only direct current Internal power supply 12 Vdc +/-20% External power supply 9 - 24 Vdc, Imax 5 mA for each sensor OUTPUTS Cumulative Reporting signal back-up alarm DATA TRANSMISSION (optional) Polarized voltage-free, only direct current Common positive configuaration...

Open the catalog to page 5
Alarm module - 6

TECHNICAL SHEET TS31 Delta PS.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M series MIN co, ANIDRIDE CARBDNICA , , CARBON DIOXIDE MAX ARIA PER SDEQA AIR FOR AGSS MIN N,0 PROfOSSIDO Dl AZOEO ,, , wNITROUS OXIDE MAX NONSTANDARD LABELS CONTAINED IN THE BOX Delta P reserve the right to change the aesthetic and technical features of the described devices.

Open the catalog to page 6
Alarm module - 7

NOTE: 3 configurations are available: 7578AS-2025M - Module for 10 electric contacts 70240AS-2025M - Module for 5 transducers 4...20 mA 70241A5-2025M - Single reporting alarm Delta P reserve the right to change the aesthetic and technical features of the described devices.

Open the catalog to page 7
Alarm module - 8

Delta P reserve the right to change the aesthetic and technical features of the described devices.

Open the catalog to page 8
Alarm module - 9

TECHNICAL SHEET TS31 Delta PS.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M series Page 7 of 10 Technical Data ALARM 4 LEDS GREEN/RED VALVE STATUS WITH NAMUR DESCRIPTION This alarm is destined to signal the opened / closed status of manual shut-off valves provided with NAMUR sensor. Up to 4 valves contemporary can be monitored POWER SUPPLY Power feeder supplied separately N. 4 inputs ON OFF for connection of NAMUR sensors N.1 output for cumulative repeating powered at +24V (Imax 30 mA] LEDSTATUS 4LEDs gneen/red in grado indicating the following status RED: valve...

Open the catalog to page 9
Alarm module - 10

TECHNICAL SHEET TS31 Delta PS.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M series Technical Data ALARM 4 LEDS GREEN/RED TO REPORT VALVE STATUS WITH NAMUR DESCRIPTION This alarm is destined to report signals of the opened/closed status of manual shut-off valves provided with NAMUR sensor Up to 4 valves contemporary can be monitored POWERSUPPLY 24 V DC +/-10 % ^feeder supplied separately _ Imax: 40 mA_ INPUT/OUTPUT N. 4 powered inputs +24V (lmax=30 mA for each input) N.1 output for cumulative repeating powered at +24V (Imax 30 mA) - upon request _DIMENSIONS BOX...

Open the catalog to page 10
Alarm module - 11

TECHNICAL SHEET TS31 Delta PS.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M series Technical Data MEDICAL ALARM WITH 16 DIGITAL INPUTS PROGRAMMABLE DISPUY DESCRIPTION Alarm module intended to be used as alarm for supply units or for ward in medical gas pipeline systems. It is equipped with an LCD display and it allows to manage alarm signals coming from a number of maximum 16 digital inputs. It is also possible to program the module as remote repeater of a single unit with digital or analog inputs POWERSUPPLY • 230 V - 50/60 Hz 6VA • 115 V or 24 V-upon request...

Open the catalog to page 11
Alarm module - 12

TECHNICAL SHEET TS31 Delta P S.r.l exportfideltap.it infofideltap.it www.deltap.it Alarm module 2025M series Page 10 of 10 Technical Data MEDICAL AURM WITH PROGRAMMABLE OLED DISPLAY6 ANALOG INPUTS AND 16 DIGITAL INPUTS DESCRIPTION Alarm module intended to be used to manage alarm signals coming from a maximum of n. 16 digital inputs. The same alarm module, if opportunely programmed, it allows to manage also n.6 analog inputs coming from transducers 4..20 mA. It is also possible to program the module as remote repeater of a single unit with digital or analog inputs POWER SUPPLY • 230 V-50/60...

Open the catalog to page 12
Alarm module - 13

SCHEDA TECNICA TS31 Delta P S.r.l exportfideltap.it infofideltap.it www.deltap.it TS31 Rev n. 01 08/02/16 Moduli di allarme serie 2025M ■ I ITA Pagina 1 di 10 CaratteristicheTecniche ALLARME DI CENTRALE COD. 2640AS-2025M DESCRIZIONE Liallarme di centrale e destinato al monitoraggio allarmi centrali di stoccaggio gas medicinali e rispettive linee primarie di distribuzione mediante pnessostati e sensori a contatto elettrico. INGRESSI sensori a contatto elettrico Polarizzati, solo corrente continua Alimentazione interna 12 Vdc+/- 20% Alimentazione esterna 9-24 Vdc, Imax 5mA persensore USCITE...

Open the catalog to page 13

All DELTA P catalogs and technical brochures

  1. DeltaP_TS23

    8 Pages

  2. DeltaP_TS50

    8 Pages

  3. TS27

    6 Pages

  4. DeltaP_TS03

    6 Pages

  5. TS06

    6 Pages

  6. TS06-LAB

    6 Pages

  7. TS38

    5 Pages

  8. BUS system

    2 Pages