TS27
6Pages

{{requestButtons}}

Catalog excerpts

TS27 - 1

Second stage pressure regulator Riduttori di pressione secondo stadio MCD Delta PS.r.l Via Thanasau, 4 20088 Rosate (Ml) - ITALY www.deltap.it

Open the catalog to page 1
TS27 - 2

Medical Gas Equipment Delta PS.r.l export@deltap.it info@deltap.it www.deltap.it Second stage pressure regulator Riduttori di pressione secondo stadio 2250M - 2251M Second stage high flow rate reducers specially projected to be installed in decompression units realized in compliance with ISO 7396-1 The reduction valve is equipped with a compensated shutter in order to assure more stability in the outlet pressure in case of variations of the inlet pressure. The reducers are composed of an aluminium cap and a brass enlock body chemical nickel plated with diaphragm servomotor, this assembling...

Open the catalog to page 2
TS27 - 3

TECHNICAL SHEET TS27 Delta PS.r.l export@deltap.it info@deltap.it www.deltap.it Second stage pressure regulator 2250M-2251M Technical Data SUITABLE FOR THE FOLLOWING GASES: 02, N20, Air, N2, C02 MAX INLET PRESSURE: 25 bar HIN INLET PRESSURE: 12 bar OUTPUT PRESSURE: 4 + 10 bar NOMINAL OUTPUT PRESSURE: 8 bar FLOWRATE: see the flow rate diagram INLET CONNECTION: G1"Ffor2250M; G1/2” F for 2251M OUTLET CONNECTION: G1MFfor2250M; G1/2" F for 2251M STORAGE TEMPERATURE: -25 + +60 °C OPERATING TEMPERATURE: 25 ++45 °C WEIGHT: 6 Kg (2250M); 3.5 Kg (2251M) DIMENSIONS: See figures STANDARDS: ISO 7396-1 ;...

Open the catalog to page 3
TS27 - 4

TECHNICAL SHEET TS27 Delta PS.r.l exporH3deltap.it infoOdeltap.it wwtAr.deltap.it Second stage pressure regulator 2250M - 2251M Page 2 of 2 Flow rate diagram Inlet pressure Conversion factors Air Oxygen Carbon Dioxide Nitrous Oxide Delta P reserve the right to change the aesthetic and technical features of the described devices.

Open the catalog to page 4
TS27 - 5

SCHEDATECNICATS27 Delta PS.r.l exporH3deltap.it infoffldeltap.it wwtAr.deltap.it Riduttore di pressione secondo stadio 2250M - 2251M II™ Pagina 1 di 2 Spetifidie Tecniche GAS DI PROCESSOi 02, N20, Aria, N2, C02 PRESSIONE DI INORESSO MASSIMA: 25 bar PRESSIONE DI INGRESSO MININA: 12 bar PRESSIONE DIUSCITA: 4+10 bar PRESSIONE DI USCITA NOMINALEi 8 bar PORTATAi vedi curve di portata CONNESSIONE DI INGRESSO: G1" F per riduttore 2250M; G1/2’ F per riduttore 2251M CONNESSIONE DI USCITA: G1" F per riduttore 2250M; G1/2” F per riduttore 2251M TEMPERATURE DI STOCCAGGIO: -25 - +60 °C TEMPERATURADI...

Open the catalog to page 5
TS27 - 6

SCHEDATECNICATS27 Delta PS.r.l exporH3deltap.it infoffldeltap.it wwtAr.deltap.it Riduttore di pressione secondo stadio 2250M - 2251M Pagina2di2 Curve di portata Pressione di ingresso Coefficient! di conversione Anidride Carbonica 0.79 Protossido d’azoto 0.79 Riduttore serie 2250M Riduttore serie 2251M Delta P si riserva il diritto di cambiare L'estetica e le caratteristiche dei dispositivi ivi descritti.

Open the catalog to page 6

All DELTA P catalogs and technical brochures

  1. DeltaP_TS23

    8 Pages

  2. DeltaP_TS50

    8 Pages

  3. DeltaP_TS03

    6 Pages

  4. TS06

    6 Pages

  5. TS06-LAB

    6 Pages

  6. TS38

    5 Pages

  7. Alarm module

    22 Pages

  8. BUS system

    2 Pages