Implant Surface
The BWS® implant surface is engineered for optimal osseointegration, using sandblasting and acid etching to enhance fibrin adhesion and bone healing. It undergoes SEM control and Argon Cold Plasma treatment to ensure cleanliness and minimize contamination.
Implant Line
The FTZ implant line offers cylindrical and conical implants with universal and internal hex connections, available in various lengths and diameters. These implants feature micro-grooves to limit bone resorption and a spiral profile for improved penetration.
Drills and Drill Stops
Drills are designed with depth notches and sharpness for precision. Drill stops are available for different lengths and diameters, ensuring optimal depth control and reducing surgical risks.
Surgical Procedures
Recommended surgical sequences and drill speeds are provided, emphasizing clinical evaluation and bone density considerations. Tappers may be used to reduce insertion torque stress.
Implant Drivers
Implant drivers are available for both contra-angle and manual use, with detailed procedures for implant insertion and removal. Torque settings are specified for different surgical approaches.
Prosthetic Components
Components for cemented and screwed prostheses include various abutments and impression copings. MUA components are detailed with specific instructions for use.
Digital Flow Components
Prosthetic components for digital workflows include scan abutments, digital analogs, and bonding bases, suitable for CAD-CAM and traditional techniques. Specific guidelines for MUA connections are provided.
Instruments and Maintenance
Instructions for cleaning and maintenance of dynamometric ratchets are included, along with a list of available spare screws.
Additional Information
The document concludes with preliminary indications for surgical instrument use, sale conditions, warnings, and trademark information.
Overview
This document provides detailed specifications, procedures, and guidelines for the use and maintenance of overdenture prosthetic components and related surgical instruments. It includes information on materials, torque specifications, cleaning, sterilization, and usage instructions.
Specifications
  • Overdenture abutments and sphere abutments are made from Ti5 titanium, compatible with Zest LOCATOR® and RHEIN83® systems.
  • Various components such as torque adapters, screwdrivers, and extensions are made from surgical stainless steel (Inox).
  • Torque specifications for screws are provided, with a recommended tightening torque of 10 Ncm for most screws and 20 Ncm for abutment screws.
Procedures
  • Detailed cleaning and maintenance procedures for dynamometric ratchets and other instruments are outlined, emphasizing the use of non-metallic brushes and specific cleaning solutions.
  • Manual cleaning and disinfection involve the use of peracetic acid solutions, followed by thorough rinsing and drying.
  • Sterilization is validated through a moist heat autoclave cycle at 134°C for 3 minutes.
Usage Recommendations
  • Instruments should be used only for their intended purposes and cleaned immediately after use.
  • Drills should not exceed 800 RPM during osteotomy, and tapping should not exceed 20 RPM.
  • Generous irrigation with physiological solution is recommended during drilling and tapping.
Packaging and Sterility
  • Tools are supplied non-sterile and must be washed and sterilized before use.
  • Instruments should be stored in a dry, dust-free environment after sterilization.
Warnings and Liability
  • Use of non-original components may compromise implant functionality.
  • Excessive torque can damage screws and instruments, leading to potential intraoperative issues.
Bibliography and References
The document cites various studies and articles related to dental implant surface topography and integration.
Contact Information
Dental Tech S.r.l. provides contact details for further inquiries and support.
See more

Catalog excerpts

FTZ-3

BWS® Implant Surface 4 FTZ Implant line (Cylindrical / Conical) 5 Drills - Reading depth notches and sharp drills 7 Drill Stop - Stop insertion and removal procedure 8 Recommended surgical sequence and drill speed 9 Implant Drivers - Implants insertion procedure 11 Components for cemented/screwed prosthesis 12 Components for MUA screwed prosthesis 13 Prosthetic components for digital flow 14 Prosthetic components for digital flow - Connection on MUA 17 Overdenture prosthetic components 18 Dynamometric ratchet cleaning and maintenance 20 Spare Screws Available 21 Preliminary indications for surgical...

 Open the catalog to page 3
FTZ-4

SANDBLASTING AND ACID ETCHING Sandblasting and etching processes of the implant surface allow to obtain optimal roughness values that make the adhesion of fibrin to the surface more tenacious and facilitate the bone healing process, significantly reducing the time. FIBRIN ADHERENCE The capacity of BWS® to retain fibrin, lets osteoblasts migrate from the bone to the implant surface and reproduce there, generating new bone in direct contact with the titanium (contact Osseointegration). THE IMPLEMENTED PROTOCOL PROVIDES VERIFICATION OF EACH BATCH OF PRODUCTION After the surface treatment and the...

 Open the catalog to page 4
FTZ-5

Implant Line FTZ Cylindrical / Conical Universal connection Internal hex connection MICRO-GROOVES Micro-grooves to limit bone resorption. The implant’s screwing axis can be adjusted. BETTER PENETRATION Spiral profile with hybrid progress: flat and radiating towards the root, trianglar-shaped externally, for greater penetration into incompletely prepared sites. APICAL With helicoidal progress to enhance stable penetration.

 Open the catalog to page 5
FTZ-6

DIAMETER - Ø 3.75 mm Cover screw included Color Code Warning! All DRP drills are 0.8 mm longer than the implant. In the planning stage and while drilling in proximity to vital anatomical structures, this added length must be considered. radio-checked Optional Indication of surgical position Recommended surgical sequence Cover screw included Color Code Warning! All DRP drills are 0.8 mm longer than the implant. In the planning stage and while drilling in proximity to vital anatomical structures, this added length must be considered. radio-checked Optional Indication of surgical position Recommended...

 Open the catalog to page 6
FTZ-7

DIAMETER - Ø 4.75 mm Cover screw included Color Code prosthetic surgical Warning! All DRP drills are 0.8 mm longer than the implant. In the planning stage and while drilling in proximity to vital anatomical structures, this added length must be considered. radio-checked Optional Indication of surgical position Recommended surgical sequence Drills - Reading depth notches and sharp drills Lance drill - Parallel drills - Countersink - Tappers Lance drill Parallel drills The colored rings identify the diameter of the surgical line

 Open the catalog to page 7
FTZ-8

Drill Stop Parallel drill L 23 mm Material: Inox Material: Inox Drill Stop - Stop insertion and removal procedure STOP insertion Hold the drill on the stalk side and insert the stop, with the retentions facing the drill, until the point of contact with the metallic stop located on the drill itself. (Fig. STOP removal Hold the stop and remove the drill by pulling on the stalk side. Depth STOP for different lengths. » Optimal check-depth during preparation of the surgical site, even in conditions of poor visibility of the operating field; » Reduction of surgical risk; » Reduction of operator stress;...

 Open the catalog to page 8
FTZ-9

checkmark checkmark checkmark checkmark checkmark checkmark checkmark checkmark LEGEND REQUIRED checkmark OPTIONAL radio-checked Warning ! In the table “Recommended surgical sequence and drill speed” parameters should be considered as general indications; the clinical evaluation should always be subjected to careful analysis by the practitioner in each specific case. Based on the clinical features and bone consistency detected at the time of implant surgery, the choice of the available instrumentation will be made by the practitioner. Tappers may be used at the operator's discretion, based on...

 Open the catalog to page 9
FTZ-10

Implant Drivers Implant CA connection - Implant ratchet connection Hexagonal implant reference Hexagonal head for ratchet Hexagonal implant reference Depth notches for flapless technique Depth notches for flapless technique 6 mm 4 mm 2 mm Implant ratchet connection Allows removal of the implant from the ampoule and its insertion in the surgical site using the contra-angle implant driver. Material: Inox A tool to be connected to the ratchet to complete insertion of the implant. Material: Inox

 Open the catalog to page 10
FTZ-11

With manual implant driver Insert the implant driver connected to the handwheel into the implant making a slight rotation to allow good matching of the two geometric figures (implant - driver) and remove the implant (Fig. 6). Begin insertion of the implant in the alveolar surgical site using the manual implant driver. Where bone density permits, it is possible complete insertion of the implant using the manual wrenches (Fig. 7). To remove, exercise a slight lateral movement, right and left, in order to free the matching (Fig. 7). Insert the direct contra-angle implant driver into the implant...

 Open the catalog to page 11
FTZ-12

Components for cemented/screwed prosthesis Parallel healing abutment Material: Ti5 H Taper healing abutment Material: Ti5 H Open tray impression coping Material: Ti5 Fastening screw included REF 05.010/VF Taper large healing abutment Material: Ti5 H Closed tray impression coping Material: Ti5 Fastening screw included REF 020237/VF Taper Large Implant analog Material: Ti5 Fastening screw included REF 020022 Straight abutment Material: Ti5 Straight abutment Material: Ti5 Overcast abutment Material: CRCO Straight abutment Material: Ti5 Package 10 pcs. Ø Castable abutment Material: Pmma Cylinder...

 Open the catalog to page 12
FTZ-13

MUA protection cap Material: Ti5 Package 2 pcs. Fastening screw included REF VPCEM Material: Ti5 Supplied with transfer handle Supplied with transport and parallelization screw Fastening screw included REF 020510/VF MUA precision transfer Material: Ti5 Fastening screw included REF VFTEM Fastening screw included REF VPCEM MUA castable Material: Pmma Fastening screw included REF VPCEM