SLIM

SLIM
1 / 28 PagesView full catalog

SLIM

Product catalog summary
Product Overview
The document is a catalogue for the SLIM Implant Line by Dental Tech Worldwide, detailing various implant lines and components for dental procedures. It includes specifications, recommended procedures, and components for prosthetic applications.
Implant Surface
The BWS® Implant Surface is noted for its optimal roughness achieved through sandblasting and acid etching, enhancing fibrin adhesion and osseointegration. It undergoes rigorous cleaning and verification, including Argon Cold Plasma treatment and SEM control, ensuring minimal contamination and high quality.
Implant Lines
  • ImpLogic® AT 3.25: A tapered implant with a spiral design for ridge expansion, offering self-tapping capabilities and high primary stability, suitable for post-extraction and poor-quality bone cases.
  • ImpLassic FT3 3.25: Features a cylindrical body with a conical apex, adaptable to all bone types, supporting both screwed and cemented prosthetic restorations. It uses platform switching to manage soft tissue and reduce bone resorption.
Surgical Procedures
Recommended surgical sequences and drill speeds are provided for both ImpLogic® AT and ImpLassic FT3 implants, emphasizing clinical evaluation and practitioner discretion based on bone density and surgical conditions.
Drills and Implant Drivers
Details on reading depth notches, drill stops, and correct procedures for insertion and removal are included. Implant drivers for both contra-angle and manual insertion methods are described, with specific torque and RPM settings.
Prosthetic Components
The catalogue lists components for cemented/screwed prostheses, MUA screwed prostheses, and digital flow prosthetic components, specified with material, dimensions, and intended use, including digital CAD-CAM applications.
Instruments and Maintenance
Instructions for cleaning and maintenance of dynamometric ratchets and other instruments are provided, ensuring longevity and reliability.
Additional Information
The document concludes with preliminary indications for surgical instrument use, sale conditions, warnings, and trademark information, providing comprehensive guidance for practitioners.
Prosthetic Components and Specifications
Details on various components such as Scan Abutment MS, MUA Digital Analogue, and MUA Bonding Base, all made from Ti5, suitable for digital CAD-CAM techniques.
Overdenture Prosthetic Components
Includes Sphere Abutment and Overdenture Abutment, both made from Ti5, with specific compatibility and usage instructions.
Instruments and Maintenance
Includes various screwdrivers, adaptors, and extensions made from Inox and Ti5, with cleaning and sterilization procedures outlined.
Cleaning and Sterilization Procedures
Manual cleaning and disinfection using peracetic acid-based solutions, and sterilization via autoclave at 134°C for 3 minutes.
Usage and Safety Recommendations
Recommended torque values and prevention measures to ensure proper use and maintenance of instruments.
Packaging and Sterility
Tools are supplied non-sterile and must be sterilized before use, with storage recommendations provided.
Disposal and Responsibility
Guidelines for disposal according to national laws and the importance of using original components to maintain functionality.
Bibliography and References
Includes studies and references related to titanium implants and surface topography.
Sale Conditions
Order acceptance, payment terms, and claims for defects are outlined.
Warnings and Trademarks
Warnings about using non-original components and a list of registered trademarks such as BWS®, IMPLOGIC®, and Zest LOCATOR®.
Materials Legend
Descriptions of materials used, such as Ti5 (Titanium gr.V ELI for medical use) and Inox (Surgical stainless steel).
See more

Catalog excerpts

SLIM-1

SLIMIMPLANT LINE PRODUCT CATALOGUE www.dentaltechworldwide.com

 Open the catalog to page 1
SLIM-3

BWS® Implant Surface 4 Implant Line ImpLogic® AT 3.25 5 Implant Line ImpLassic FT3 3.25 6 ImpLogic® AT - Recommended surgical sequence and drill speed 8 ImpLassic FT3 - Recommended surgical sequence and drill speed 8 Drills - Reading depth notches and sharp drills 9 Drill Stop - Stop insertion and removal procedure 10 Implant Drivers - Implants insertion procedure 11 Components for cemented/screwed prosthesis 12 Components for MUA screwed prosthesis 13 Prosthetic components for digital flow 14 Prosthetic components for digital flow - Connection on MUA 17 Overdenture prosthetic components 18 Dynamometric...

 Open the catalog to page 3
SLIM-4

SANDBLASTING AND ACID ETCHING Sandblasting and etching processes of the implant surface allow to obtain optimal roughness values that make the adhesion of fibrin to the surface more tenacious and facilitate the bone healing process, significantly reducing the time. FIBRIN ADHERENCE The capacity of BWS® to retain fibrin, lets osteoblasts migrate from the bone to the implant surface and reproduce there, generating new bone in direct contact with the titanium (contact Osseointegration). THE IMPLEMENTED PROTOCOL PROVIDES VERIFICATION OF EACH BATCH OF PRODUCTION After the surface treatment and the...

 Open the catalog to page 4
SLIM-5

Implant Line ImpLogic® AT 3.25 (Active Thread) Tapered implant that, thanks to its special spiral design, facilitates the users in the realization of Ridge Expansion procedures. The exceptional self tapping power of the thread, provides an excellent bone condensing and a high primary stability even in very complex clinical cases. ImpLogic® AT is recommended in cases of post extraction implants and in case of poor quality bone. SPIRAL DESIGN The unusual spiral design simplifies the procedures of Ridge Expansion. RISK REDUCTION Less risk of damaging adjacent teeth and perforation of the lingual...

 Open the catalog to page 5
SLIM-6

Implant Line ImpLassic FT3 3.25 Fixture with cylindrical body and a conical apex Modulating the surgical procedure it is indicated in all bone types; even in the case of non-compact bone it is able to achieve a good primary stability. You can use it for any type of prosthetic restoration, screwed and cemented. Using the concept of platform switching allows you to better manage the soft tissue in the area of the implant – abutment interface, and reduce peri-implant bone resorption over time. BETTER PENETRATION Spiral profile with hybrid progress: flat and radiating towards the root, triangular-shaped...

 Open the catalog to page 6
SLIM-7

ImpLogic® AT DIAMETER - Ø 3.25 mm Cover screw included Color Code Warning! All DRP drills are 0.8 mm longer than the implant. In the planning stage and while drilling in proximity to vital anatomical structures, this added length must be considered. Indication of surgical position Recommended surgical sequence Bone D4/3 Color Code Cover screw included Warning! All DRP drills are 0.8 mm longer than the implant. In the planning stage and while drilling in proximity to vital anatomical structures, this added length must be considered. radio-checked Optional radio-checked Indication of surgical position...

 Open the catalog to page 7
SLIM-8

LEGENDREQUIRED checkmarkOPTIONAL © Warning ! In the table “Recommended surgical sequence and drill speed” parameters should be considered as general indications; the clinical evaluation should always be subjected to careful analysis by the practitioner in each specific case. Based on the clinical features and bone consistency detected at the time of implant surgery, the choice of the available instrumentation will be made by the practitioner. LEGEND REQUIRED checkmark Warning ! In the table “Recommended surgical sequence and drill speed” parameters should be considered as general indications;...

 Open the catalog to page 8
SLIM-9

Lance drill - Parallel drills - Countersink - Tappers Lance drill Parallel drills Drill stop STOP 0 4-5 mm Material: Ti5 Parallel drill L 23 mm Material: Inox Implant lenght (L) mm Countersink Material: Inox The Tappers can be used, at the operator's discretion, based on the bone consistency found at the surgical site and to reduce the implant insertion tension.

 Open the catalog to page 9
SLIM-10

Drill Stop - Stop insertion and removal procedure STOP insertion Hold the drill on the stalk side and insert the stop, with the retentions facing the drill, until the point of contact with the metallic stop located on the drill itself. (Fig. 1 - 2- 3). Warning WRONG insertion STOP Stop insertion with the retentions facing the tip of the drill is incorrect. (fig. 4 - 5). STOP removal Hold the stop and remove the drill by pulling on the stalk side. Depth STOP for different lengths. The advantages: » Optimal check-depth during preparation of the surgical site, even in conditions of poor visibility...

 Open the catalog to page 10
SLIM-11

With manual implant driver Insert the implant driver connected to the handwheel into the implant making a slight rotation to allow good matching of the two geometric figures (implant - driver) and remove the implant (Fig. 6). Begin insertion of the implant in the alveolar surgical site using the manual implant driver. Where bone density permits, it is possible complete insertion of the implant using the manual wrenches (Fig. 7). To remove, exercise a slight lateral movement, right and left, in order to free the matching (Fig. 7). Insert the direct contra-angle implant driver into the implant...

 Open the catalog to page 11
SLIM-12

Components for cemented/screwed prosthesis Taper healing abutment Material: Ti5 Closed tray impression coping Material: Ti5 Fastening screw included REF VTST32 Open tray impression coping Material: Ti5 Fastening screw included REF VTPR3200 Implant analog Material: Ti5 Fastening screw included REF VFD032 Straight abutment Material: Ti5 H Castable abutment Material: Pmma Straight abutment Package 10 pcs. Material: Ti5 Angled abutment Material: Ti5 Overcast abutment Material: CRCO REF 7,5mm 5,5mm 3,5mm Cutting line for use in digital environment Cylinder abutment Material: Ti5

 Open the catalog to page 12
SLIM-13

MUA protection cap 03.25 Material: Ti5 Package 2 pcs. Fastening screw included REF VPCEM Supplied with transport and parallelization screw Fastening screw included REF VMF325 MUA CrCo 03.25 Material: CRCO Fastening screw included REF VPCEM MUA castable 03.25 Material: Pmma Fastening screw included REF VPCEM

 Open the catalog to page 13

All DENTAL TECH S.R.L. catalogs and technical brochures

  1. TISSUE LEVEL

    28  Pages

  2. FTK

    28  Pages

  3. FTZ

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.