M-^rl J. (Dentium Advanced Sinus Kit) Catalog & Manual
Open the catalog to page 1Sinus elevator / OSTEON™ II 11
Open the catalog to page 2DASK Products Introduction of DASK Drills for Crestal Approach The distance from the alveolar crest to the sinus floor should be measured on x-rays prior to surgery. Site preparation is preformed with twist drills in sequence up to 1mm short of the sinus floor. Then DASK Drill #1 or #2 is used and the sinus floor is carefully approached under light apical pressure. When you feel the sinus floor yields, remove the drill. Or, partial preparations with DASK Drill #1 or #2 and up-fracture with osteotomes can be performed. * The internal irrigation not only provides a cooling effect, but also...
Open the catalog to page 3DASK Products Crestal Approach (Sinus Lifting) Thin-out Technique After Ø3.8 Final drilling, eliminate the residual bone (1mm) using a DASK Drill #1 or #2. (in hard bone) until you feel a slight drop. Use the dome-shaped sinus curette. Detaching the sinus membrane to create adequate space for graft material. Use [OSTEON™ Lifting] bone graft material. To fill the sinus through the osteotomy site. Fill and distribute OSTEON™ properly into the Created space. Placement of implant into the osteotomy site. Use an osteotome to make a greenstick fracture. Use a dome-shaped sinus curette to gently...
Open the catalog to page 4DASK Products Crestal Approach (Sinus Lifting) Clnical Case : Crestal Approach Preoperative panoramic view :Due to caries, elongation and tilt, tooth 15 and 16 have to be extracted Postoperative panoramic view DASK Drill #1 with a depth stopper to thin out the cortical bone of sinus floor Bone graft material (OSTEON™Lifting) is filled into the created space Finally prosthesis in situ (Zirconia ceramic bridge). A dome-shpaed sinus currette is introduced to detach the schneiderian membrane from the sinus floor Graft material evenly distributed laterally with a sinus-curette Implants...
Open the catalog to page 5DASK Products Lateral Approach (Sinus Elevation) Wall-off Technique Detach sinus membrane using a dome-shape sinus curette. DASK Drill #6 is used to cut a round bony island from the lateral wall like a trephine bur. Start to drill at a desired location and proceed until you see the shadow of sinus membrane. Then separate and lift the bony island up from the neighboring wall with a molt curette or a periosteal elevator. The bony island is repositioned back in its original position after bone augmentation. The first laser mark is 1.5mm and the second is 3.0mm. Overdrilling can cause sinus...
Open the catalog to page 6DASK Products Lateral Approach (Sinus Elevation) Clinical Case 1 : Wall-off Technique Preoperative panoramic view Postoperative panoramic view DASK Dril #6 to prepare a bony window The maxillary sinus is opened via a lateral window The bony island can be repositioned after bone augmentation Flaps Closed Clinical Case 2 : Thin-out Technique Preoperative panoramic view Postoperative panoramic view DASK Drill #4 for antrostomy approach onto the lateral wall of the maxilla. A dome-shaped sinus curette is used first around the bony window for sinus membrane detachment Implants placed with bone...
Open the catalog to page 7DASK Products DASK (Dentium Advanced Sinus Kit) DASK • Simple & easy access to sinus cavity • Broad exposure of bony walls with special instruments DASK Drill | Scale 1 : 1.2 / mm Ø3.3 DASK Drill # DASK Drill #1 Lateral Approach Crestal Approach ※ Note DASK Drill #1~5 : Drill speed 800 to 1,200rpm, 30~45N.cm with internal irrigation DASK Drill #6:Drill speed 800 to 1,200rpm, 30~45N.cm with external irrigation XRT084025 Stopper | For XRT332035, XRT372035, XED331035D | Scale 1 : 1 / mm Drilling Depth
Open the catalog to page 8DASK Products DASK (Dentium Advanced Sinus Kit) Sinus Elevation Instrument | Scale 1 : 0.6 / mm REF Osteotomes compress the bone laterally, providing denser bony interface rather than removing valuable bone from the surgical site. Osteotomes | Final drill type / Scale 1 : 0.4 / mm ØB
Open the catalog to page 9DASK Products DASK Maintenance Sterilization and Instrument Care Procedures • Please follow legal regulations, as well as hygienic guidelines to prevent contamination and infection. • Please remember that you are responsible for the maintenance and sterility of your medical/dental products/device. It is important to use and follow proper cleaning, disinfection and sterilization procedures. • It is also important to follow the manufacturer's recommendation on usage of drills. Please keep a log as to how many times the drills are used. • Drill usage is determined by surgical site not per...
Open the catalog to page 10DASK Products Sinus elevator • Makes the sinus lift easy, and drastically reduce the possibility of membrane perforation • Balloon expansion of 0.5cc saline equals 6mm of membrane elevation Balloon inflation size(mm) Injection Volume(cc) OSTEON™ II (Sinus & Lifting) • Osteoconductive synthetic bonegraft • Almost resorbable due to higher β-TCP content(HA:β-TCP = 30:70) • Easy manipulation • Excellent wettability OSTEONTM II = HA 30% + β-TCP 70% Cell adhesion test Osteoblast attached & spreaded well
Open the catalog to page 11(Dentium Advanced Sinus Kit) Catalog & Manual For Dentists BV Dentists Some products that are to be launched in the market after necessary approvals are also listed in this catalog. 3105 Trade Tower, 513 Yeongdong-daero, Gangnam-gu, Seoul, Korea 135-731 T+82-2-501-8560 F+82-2-567-9578
Open the catalog to page 12All Dentium catalogs and technical brochures
-
SlimLine
28 Pages
-
Overdenture System
26 Pages
-
SuperLine Product
130 Pages
-
Instrument Catalog
46 Pages
-
Regeneration
26 Pages
-
Why Dentium
52 Pages
-
Digital dentistry 1403
20 Pages
-
lab system
38 Pages
-
Dental Lab System
44 Pages
-
SlimLine SPM-1403
28 Pages
-
Implantium II
68 Pages
-
Surgical Guide SGCM-1312 [Rev.1]
15 Pages
-
Paste Stain
2 Pages
-
Temporary Shell_1501 1501
4 Pages
-
Introduction of Dentium 2014
23 Pages
-
Maxillofacial Implant
20 Pages
-
Help kit XIH-1301
16 Pages
-
SimpleLine II Product
42 Pages
-
Product from Dentium
48 Pages
-
RS Kit RSKP-1308
12 Pages
-
GBR system GSPS-1304
16 Pages
-
NR Line Product Catalog
49 Pages
-
rainbow Porcelain
26 Pages
-
Lab Product catalog
24 Pages