1. Catalogs
  2. Dentium
  3. NR Line Product Catalog
video corpo

NR Line Product Catalog

NR Line Product Catalog
1 / 49 PagesView full catalog

NR Line Product Catalog

Product catalog summary

1. Overview and General Specifications

This technical document focuses on dental implant components, including impression copings, analogs, abutments, and related accessories. It provides detailed dimensional data and compatibility information for various implant systems such as GCS36, NFX3609S, GDAB5525S, GMAB4325S, and GAAB154325S.

2. Components and Their Specifications

  • Impression Copings: Available in diameters of 3.7 mm, 4.3 mm, 5.5 mm, and 6.5 mm, with pick-up and transfer types. Designs include round and double square, with screw and non-screw options.
  • Analogs: Matched to impression copings by diameter and implant system compatibility.
  • Comfort Caps and Cover Screws: Included to enhance patient comfort and secure implant components.
  • Abutments and Cylinders: Metal-casting abutments, titanium temporary abutments, base and healing abutments, Ti-cylinders, burn-out cylinders, and metal cylinders are specified with diameters (4.3 mm, 5.5 mm) and angulations (notably 25°).

3. Dimensional and Compatibility Data

Precise platform diameters (3.2 mm, 3.6 mm, 4.3 mm) and body diameters (3.1 mm, 3.6 mm) are provided to ensure correct component matching. Compatibility is emphasized with implant systems such as GAAB254325S, NFX3609S, GRAB43CS, and others, ensuring interoperability and correct prosthetic fit.

4. Procedures and Recommendations

  • Impression Taking: Use of pick-up and transfer impression copings with corresponding screws for accurate impressions.
  • Abutment Installation: Placement of base, healing, and temporary abutments with specified torque values (300-500 gf, 500-700 gf) to ensure secure fixation.
  • Drilling Protocols: Use of first guide drills and final drills with defined diameters and lengths for implant site preparation.
  • Magnetic Assay: Use of implant keepers with diameters of 4.5 mm and 5.5 mm for magnetic testing procedures.

5. Standards and Norms

The document references standards such as NFX3609S, ensuring adherence to recognized norms for dental implant components. This guarantees quality, safety, and interoperability within the dental implantology field.

6. Critical Parameters and Limitations

  • Exact matching of component diameters to implant platform sizes is critical to avoid misfits.
  • Correct selection between pick-up and transfer impression coping types is essential for impression accuracy.
  • Torque specifications must be strictly followed to prevent component loosening or damage.
  • Material compatibility and selection impact biocompatibility and mechanical performance.
  • Cross-compatibility between implant systems is limited; components must be matched to specific systems.

7. Best Practices

  • Verify implant platform and body diameters before component selection.
  • Adhere strictly to manufacturer torque guidelines during abutment and screw installation.
  • Use protective caps and delivery holders to maintain component integrity during handling and processing.
  • Follow recommended drilling sequences and protocols to preserve implant site integrity.
  • Confirm impression coping type and placement technique to ensure accurate prosthetic outcomes.
  • Maintain compliance with standards such as NFX3609S for quality assurance.

8. Summary of Key Data Extracted from Tables and Figures

  • Platform diameters: 3.2 mm, 3.6 mm, 4.3 mm.
  • Body diameters: 3.1 mm, 3.6 mm.
  • Impression coping diameters: 3.7 mm, 4.3 mm, 5.5 mm, 6.5 mm.
  • Component types include round, double square, and angled (15° and 25°) variants.
  • Torque ranges for screws and abutments: 300-500 gf and 500-700 gf.
  • Compatibility with implant systems: GCS36, NFX3609S, GDAB5525S, GMAB4325S, GAAB154325S, GAAB254325S, GRAB43CS, GRAB43TS, GSAB4325, GAOS4310, GAOB432020S, MGT4520D, GMK4525D, BPF3, GBAB4325.
  • Drill sizes and sequences specified for implant site preparation.

Note: Some sections of the original document were corrupted or unreadable; this summary is based on the interpretable content extracted.

See more

Catalog excerpts

NR Line Product Catalog-3

Dual Abutment - Abutment Level Impression Dual Abutment [Double Square] Dual Abutment [Round] Abutment Level Impression Components Dual / Dual Milling / Angled / Metal-Casting / Temporary Abutment - Fixture Level Impression Fixture Level Impression Components Dual Milling Abutment Metal Casting Abutment Temporary Abutment )4 Screw Abutment - Abutment Level Impression 28 17 Angled Screw Abutment 30 )8 Screw Abutment Impression Components 31 Mini Ball Attachment - Abutment Level Impression Mini Ball Attachment Angled Mini Ball Attachment Magnetic Attachment Prosthetic and Laboratory Instrument

 Open the catalog to page 3
NR Line Product Catalog-6

06 NR Line Product Catalog Abutment screw 01.9 hole size for occlusion. Dual Abutment ■ Body 03.1 fixture is very useful for narrow ridge. • Platform 04.3 fixture is good for high occlusal stress. Minimize bone and gingival resorption Extended thread design Extended thread design helps increase the initial stability. bone & soft tissue ■ Compatible with bone & tissue level Firm & stable connection (Internal 10° taper & double square shape) Less screw, abutment & fixture fracture 10° taper & double square shape between implant and abutment interface ensures tight sealing. Double square connection(octa)...

 Open the catalog to page 6
NR Line Product Catalog-7

NR Line Product Catalog 07 NR Line Color Coding by Diameter Color Coding by Diameter Cover screw is not included in the packaging. (Mount Free) Selection Guideline Anterior Premolar

 Open the catalog to page 7
NR Line Product Catalog-8

08 NR Line Product Catalog * Note: 1) To prevent damage to the Implant driver or fixture, do not over torque during fixture insertion

 Open the catalog to page 8
NR Line Product Catalog-9

NR Line Product Catalog 09 Cover Screw Cover Screw ^Square driver: Use no more than 5N-cm torque when screwing a cover screw to a fixture. If double square is worn, slot on the head of the product can be used to rotate it.

 Open the catalog to page 9
NR Line Product Catalog-10

10 NR Line Product Catalog Healing Abutment ^Square driver: Use no more than 5N-cm torque when screwing a healiing abutment to a fixture. If double square is worn, slot on the head of the product can be used to rotate it.

 Open the catalog to page 10
NR Line Product Catalog-11

NR Line Product Catalog 11 Impression Technique and Restoration Selection Dual Abutment Abutment Level Impression Closed Tray Technique Dual Abutment Double Square / Round 03.7/04.3/05.5/06.5 Impression Coping (Burn-Out Cylinder, Comfort Cap, Abutment Holder) Cemented Restoration

 Open the catalog to page 11
NR Line Product Catalog-12

12 NR Line Product Catalog Dual Abutment [Double Square] Abutment screw is included. Diameter 03.7 | Double square Diameter 04.3 | Double square ^Note: 1) If the NR Line fixture with size of 03.1 straight type is used, abutment height after assembly will become 1.0mm longer than other sized fixtures. 2) It is recommended to keep the torque level at 20 Ncm to tighten the dual abutment with fixture.

 Open the catalog to page 12
NR Line Product Catalog-13

NR Line Product Catalog 13 Dual Abutment [DO uble Square] Abutment screw is included. Diameter 05.5 | Double square Diameter 06.5 | Double square ^Note: 1) If the NR Line fixture with size of 03.1 straight type is used, abutment height after assembly will become 1.0mm longer than other sized fixtures. 2) It is recommended to keep the torque level at 20 N-cm to tighten the dual abutment with fixture.

 Open the catalog to page 13
NR Line Product Catalog-14

14 NR Line Product Catalog Dual Abutment [Round] Abutment screw is included. ^ Note: 1) If the NR Line fixture with size of 03.1 straight type is used, abutment height after assembly will become 1.0mm longer than other sized fixtures. 2) It is recommended to keep the torque level at 20 N-cm to tighten the dual abutment with fixture.

 Open the catalog to page 14
NR Line Product Catalog-15

NR Line Product Catalog 15 Dual Abutment [Round] Abutment screw is included. ^Note: 1) If the NR Line fixture with size of 03.1 straight type is used, abutment height after assembly will become 1.0mm longer than other sized fixtures. 2) It is recommended to keep the torque level at 20 N-cm to tighten the dual abutment with fixture.

 Open the catalog to page 15
NR Line Product Catalog-16

16 NR Line Product Catalog Abutment Level Impression Components

 Open the catalog to page 16
NR Line Product Catalog-17

NR Line Product Catalog 17 Impression Technique and Restoration Selection Dual / Dual Milling / Angled / Metal-Casting / Temporary Abutment Fixture Level Impression Open Tray Technique Closed Tray Technique (Complication case) (Simple case) Double Square Round Impression Coping Pick-up Double Square / Round Double Square Round Impression Coping Transfer £J Double Square / Round Dual Milling Double Square / Round Double Square / Round Double Square / Round Double Square / Round Double Square / Round Modification Modification Cemented Restoration Screw-Retained Restoration

 Open the catalog to page 17
NR Line Product Catalog-18

18 NR Line Product Catalog Fixture Level Impression Coping • Impression coping screw is included with Impression coping. Impression Coping Pick-up 03.7 Double Round Double Round square square Double square Round

 Open the catalog to page 18
NR Line Product Catalog-19

NR Line Product Catalog 19 Fixture Level Impression Coping • Impression coping screw is included with Impression coping.

 Open the catalog to page 19
NR Line Product Catalog-20

20 NR Line Product Catalog Fixture Level Impression Coping • Impression coping screw is included with Impression coping. Impression Coping Transfer 03.7 Double Round Double Round square square Double square Round

 Open the catalog to page 20
NR Line Product Catalog-21

NR Line Product Catalog 21 Fixture Level Impression Coping • Impression coping screw is included with Impression coping. Double square Round Double square Round Double square Round Impression Coping Transfer Screw

 Open the catalog to page 21
NR Line Product Catalog-22

22 NR Line Product Catalog Dual Milling Abutment Abutment screw is included. Double Round Double Round Double Round square square square Double square Double square Double square Double Round Double Round Double Round square square square ^Note: 1) If the NR Line fixture with size of 03.1 straight type is used, abutment height after assembly will become 1 .Omm longer than other sized fixtures. 2) It is recommended to keep the torque level at 20 N-cm to tighten the dual milling abutment with fixture.

 Open the catalog to page 22
NR Line Product Catalog-23

NR Line Product Catalog 23 Dual Milling Abutment Abutment screw is included. Double Round Double Round Double Round ^Note: 1) If the NR Line fixture with size of 03.1 straight type is used, abutment height after assembly will become 1 .Omm longer than other sized fixtures. 2) It is recommended to keep the torque level at 20 N-cm to tighten the dual milling abutment with fixture.

 Open the catalog to page 23
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.