Info File Infection Control - 1

Info File Infection Control Instrument reprocessing in the dental practice dentsplysirona.com

Open the catalog to page 1
Info File Infection Control - 2

Infection control systems for a high level of safety Infection control in dental practices is becoming even more important, and with such significance comes increased monitoring. Ensure all-round protection for yourself, your practice team and your patients by using instrument reprocessing with a high level of hygienic safety and comprehensive documentation options. Infection control solutions from Dentsply Sirona are suitable for the cleaning, care, disinfection and sterilization of dental instruments. Regardless of the design of your infection control workflows, we have the appropriate...

Open the catalog to page 2
Info File Infection Control - 3

Instrument reprocessing Straight and contra-angle handpieces, turbines, ultrasonic / sonic handpieces and tips, nozzles of multifunctional syringes and powder jet devices as well as powder jet handpieces place increased requirements on diligent reprocessing as a result of the narrow media channels and the angled interior spaces. Difficulty is increased by technological contaminations such as abrasion and oil residues in addition to typical contaminations from treatments such as blood, saliva, secretions and tissue. In principle, straight and contra- angle handpieces and turbines must be...

Open the catalog to page 3
Info File Infection Control - 4

The infection control cycle in machine instrument reprocessing Instrument reprocessing methods Cleaning and disinfection It begins with correct hand hygiene and thorough disinfection of all patient-related surfaces. Emphasis is placed on the correct reprocessing of medical devices – an ever-present process. It affects all instruments that are brought into the reprocessing room after treatment. Such instruments are then put through comprehensive reprocessing consisting of cleaning, disinfection1 or sterilization2, wrapping – if necessary – and wrapped sterilization. The effectiveness and...

Open the catalog to page 4
Info File Infection Control - 5

DAC Universal D and DAC Universal S Advantages • Guided maintenance workflow Check & Clean • Low operating and consumption costs – no use of cleaning and disinfection chemicals and only up to 800 ml1 / 900 ml2 water consumption per cycle • Low investment costs in instruments thanks to cooling at the end of the process and therefore quick return to service Comply with infection control standards at the touch of a button and avoid cross contamination: Completely safe with DAC Universal. Your patients and employees can rely on this all-round protection and put their complete trust in the...

Open the catalog to page 5
Info File Infection Control - 6

DAC Universal D – with disinfection Reprocessing of rotating instruments in a single cycle with the Program Blue Lid Fully automated reprocessing process DAC Universal D cleans, lubricates (if necessary) and disinfects* up to six straight and contra-angle handpieces and turbines in a fully automated process. Furthermore, ultrasonic / sonic handpieces and tips, nozzles of multifunctional syringes and powder jet devices as well as powder jet handpieces can be reprocessed at a very high level of hygienic safety in DAC Universal D. Lid variations Internal cleaning with cold water Fully...

Open the catalog to page 6
Info File Infection Control - 7

DAC Universal S – with sterilization Fully automated reprocessing process Reprocessing of rotating instruments in a single cycle with the Program Pink Lid DAC Universal S cleans, lubricates (if necessary) and sterilizes up to six straight and contra-angle handpieces and turbines in a fully automated process. Furthermore, ultrasonic / sonic handpieces and tips, nozzles of multifunctional syringes and powder jet devices as well as powder jet handpieces can be reprocessed at a very high level of hygienic safety in DAC Universal S. Lid variations Internal cleaning with cold water Fully...

Open the catalog to page 7
Info File Infection Control - 8

Information on the validation of DAC Universal D and DAC Universal S The following information is provided in line with the statutory requirements Validation is a process that tests the effectiveness and reproducibility of the reprocessing procedure. It is composed of installation qualification (IQ), operational qualification (OQ) and performance qualification (PQ). If the relevant authorities demand complete and comprehensive initial validation on-site in the practice, there are various dealers and service providers that offer such on-site validation services. Complete initial validation...

Open the catalog to page 8
Info File Infection Control - 9

Process documentation Process documentation enables complete verification of uccessful reprocessing. s Here, it is not only the process parameters that are stored electronically; compliance with the batch-specific parameters with chemical indicators is also documented. Electronic batch and process documentation, e.g., Charly, Dampsoft, diosMP, DOCma, Sego®, my:MPG REF. 65 43 172 Process documentation via USB stick Time, temperature, serial number and c orrect running of the sterilization / disinfection are documented. The data are stored digitally on the device on a data logger, e.g.,...

Open the catalog to page 9
Info File Infection Control - 10

Requirements and information on installation Market overview of care and infection control devices Requirements on location: Place DAC Universal in a well-ventilated location on a flat, heat-resistant table top near to a power source. A compressed air connection of 5 to 8 bar flow pressure is required. The recommended minimum distance to the wall is 10 cm. Further, there must be enough space to enable DAC Universal to be opened upward. The total height of the open DAC Universal is 59 cm. The minimum height should be 70 cm in order to prevent possible injuries when opening the lid (risk of...

Open the catalog to page 10
Info File Infection Control - 11

DAC Premium Plus E: Highest standards easily achieved Patented DRYtelligence® High loading capacity All-round simplicity The intelligent system makes for the perfect drying results whilst shortening the drying time by up to 80%. The mount for eight trays allows efficient use of the maximum load of up to 9 kg. Patented double-jacket technology XXL color-touch display Documentation and approval is performed quickly, safely and paper-free directly on the display of the autoclave. With the extra-large color touch display, the appearance of the DAC Premium Plus E autoclave also makes it stand...

Open the catalog to page 11

All Dentsply Sirona catalogs and technical brochures

  1. T1, T2 and T3

    13 Pages

  2. CEREC®

    17 Pages

  3. Sirona Hub

    4 Pages

  4. Atlantis

    3 Pages

  5. Xive

    112 Pages

  6. T4 BASIC

    2 Pages

  7. T2 REVO

    8 Pages

  8. SINIUS

    15 Pages

  9. VARIO DG

    2 Pages

  10. ORTHOPHOS XG 3

    10 Pages

  11. GALILEOS

    5 Pages

  12. CAD/CAM

    17 Pages

  13. XIOS PLUS

    5 Pages

  14. SIROBoost

    3 Pages

  15. SIROPure

    12 Pages

  16. Inlab System

    5 Pages

  17. TENEO

    25 Pages