1. Catalogs
  2. Depuy Synthes
  3. Titanium Sternal Fixation System
video corpo

Titanium Sternal Fixation System

Titanium Sternal Fixation System
1 / 34 PagesView full catalog

Titanium Sternal Fixation System

Product catalog summary
Introduction
The Titanium Sternal Fixation System by DePuy Synthes is designed for stable internal fixation of the sternum post-surgery or fracture. It includes various titanium plates such as straight locking plates, sternal body plates, and star-shaped plates. It is not recommended for acute cardiac patients.
Product Information
The system features self-tapping and self-drilling locking screws for secure fixation, and an emergency release pin for quick reentry in cardiac emergencies. Mechanical tests show system strength, though clinical performance may vary.
AO Principles
The system follows AO principles: anatomic reduction, stable fixation, preservation of blood supply, and early mobilization.
Indications
Indicated for sternal closure/repair to stabilize and promote fusion. Warnings include potential device breakage and allergic reactions in nickel-sensitive patients.
Surgical Technique
  • Positioning: Patient's arms are tucked for chest closure.
  • Debridement: Remove wires and devitalized tissue, ensuring hemostasis.
  • Exposure: Elevate pectoralis major muscles for midline approximation.
  • Measurement: Use a depth gauge for sternal edges and drill bit length.
  • Reduction: Align sternum with reduction forceps, avoiding vessels and nerves.
  • Template and Plate Selection: Cut and contour a template, then select and contour the plate.
  • Drilling and Screw Insertion: Drill holes and insert screws, ensuring they do not extend excessively.
  • Final Steps: Use a minimum of three plates for stability.
Alternative Technique
Self-drilling screws offer flexibility based on surgeon preference.
Emergency Reentry
Features for quick reentry include specific instructions for pin removal and reinsertion.
Implants and Instruments
Detailed lists of required implants and instruments ensure comprehensive surgical preparation.
Specifications and Recommendations
Use a minimum of three plates for optimal closure. Avoid direct contact between stainless steel wires and titanium implants to prevent corrosion. Discard fragments in an approved sharps container.
Surgical Technique
An optional manubrium plate can provide extra support. Screws should be inserted bicortically. For closure, irrigate with antibiotic saline, insert drains, and close in layers. Avoid lifting the patient by the arms for six weeks.
Alternative Technique with Self-drilling Screws
Self-drilling screws are an alternative to self-tapping screws. Insert screws perpendicular to the plate, ensuring minimal extension beyond the posterior cortex.
Emergency Reentry
Remove emergency release pins for reentry. Use forceps to reposition plate halves and insert a new pin for reclosure.
Implants and Instruments
Includes various titanium plates and screws, such as H-Plates and Star Plates. Instruments include drill bits, calipers, and bending pliers. Cleaning and sterilization instructions are available online.
Overview
Detailed list of components and tools for the DePuy Synthes Titanium Sternal Fixation System, including specifications for plates, screws, and instruments.
Specifications
  • Titanium Sternal Locking Plates: Available in various designs with different hole counts.
  • Locking Screws: 3.0 mm titanium screws in self-tapping and self-drilling variants.
  • Drill Bits: Stryker J-latch and hex coupling drill bits with stops.
Tools and Accessories
  • Bending Tools: Includes bending insert screws and pliers.
  • Forceps: Sternal and bone reduction forceps.
  • Cutting Tools: Plate and rod cutters.
Additional Products
  • Emergency Release Pins: Available in sterile packs.
  • Fixation Kits: Large H plate kits with self-drilling screws.
Important Notes
  • Products available in sterile and non-sterile forms.
  • Contraindications for certain products in acute cardiac patients.
  • Federal law restricts sale to physicians.
Contact Information
Contact numbers for orders in the USA and Canada are provided, along with a disclaimer on warranty and product labels.
See more

Catalog excerpts

Titanium Sternal Fixation System-1

For Stable Internal Fixation of the Sternum Titanium Sternal Fixation System Surgical Technique

 Open the catalog to page 1
Titanium Sternal Fixation System-2

Introduction Titanium Sternal Fixation System 2 Surgical Technique Surgical Technique 7 Alternative Technique with Self-drilling Screws 17 Product Information Implants 21 MR Information The Titanium Sternal Fixation System has not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the Titanium Sternal Fixation System in the MR environment is unknown. Scanning a patient who has this device may result in patient injury. Titanium Sternal Fixation System Surgical Technique DePuy Synthes...

 Open the catalog to page 2
Titanium Sternal Fixation System-3

Titanium Sternal Fixation System. For stable internal fixation of the sternum. The DePuy Synthes Titanium Sternal Fixation System provides stable internal fixation of the sternum following a sternotomy or fracture of the sternum. Broad variety of sternal plates Different titanium plates according to the anatomical structures and patient’s need are available: – Straight locking plates for a stable sternal rib-to-rib fixation – Sternal body plates for minimal dissection – Star-shaped and H-shaped locking plates for fixation of the manubrium – Titanium sternal locking straight plate without pin...

 Open the catalog to page 3
Titanium Sternal Fixation System-4

Titanium Sternal Fixation System Self-tapping and self-drilling locking screws Both self-tapping and self-drilling locking screws are available to accommodate surgeon preference. Secure and stable locking The plate functions like an external fixator, applied internally. The screwhead of the sternal locking screws locks securely into the threaded plate hole to provide stable fixation (Figure1). Emergency release pin on all plates‡ All plates consist of two parts joined by a U-shaped release pin in the cross section. The release pin allows a quick and easy sternal reentry in cardiac emergency cases...

 Open the catalog to page 4
Titanium Sternal Fixation System-5

Titanium Sternal Fixation System Construct strength comparison Constructs loaded in tension in lateral direction. All tests were performed on 10 mm thick composite polyurethane foam test blocks composed of an inner (cancellous) core of 5 lb/ft 3 polyurethane foam with a 1.25 mm thick (cortical) shell of 10 lb/ft 3 polyurethane foam laminated to the exterior.* Sample test construct (X-Plate setup shown) 0 Cerclage wire (8x, 0.8 mm) Stainless steel X-Plates, wide (2x, 460.040) Titanium * echanical test data on file at DePuy Synthes. M Mechanical test results may not necessarily be indicative of...

 Open the catalog to page 5
Titanium Sternal Fixation System-6

In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation.1,2 In 1958, the AO formulated four basic principles, which have become the guidelines for internal xation1, 2. Anatomic reduction Anatomic reduction Fracture reduction and fixation to Fracture reduction and xation to restore anatomical relationships. restore anatomical relationships. 1 Early, active mobilization Early, active Early and safe mobilization and Early and safe mobilization rehabilitation of the injured part rehabilitation of the injured and the patient as a whole. and the patient...

 Open the catalog to page 6
Titanium Sternal Fixation System-7

Primary or secondary closure/repair of the sternum following sternotomy or fracture of the sternum, to stabilize the sternum and promote fusion. Warnings: – hese devices can break during use (when subjected to T excessive forces or outside the recommended surgical technique). While the surgeon must make the final decision on removal of the broken part based on associated risk, in doing so, we recommend that whenever possible and practical for the individual patient, the broken part should be removed. – edical devices containing stainless steel which may M elicit an allergic reaction in patients...

 Open the catalog to page 7
Titanium Sternal Fixation System-8

Surgical Technique 1 Position patient Position the patient with the arms tucked along the sides. Avoid placing arms at 90° on arm boards, as this makes chest closure more difficult. 2 Debride (for secondary closure of the sternum) Remove existing wires. Debride the involved sternal edges until they are free of devitalized tissue and down to bleeding tissue. Hemostasis should be obtained. A curette can be used to remove any nonviable cartilaginous rib. Precautions: A sternal bone specimen should be sent to pathology to assess for osteomyelitis. Antibiotic treatment should be based on the identification...

 Open the catalog to page 8
Titanium Sternal Fixation System-9

Surgical Technique 3 Expose ribs laterally, if necessary Beginning medially, elevate the pectoralis major muscles with overlying soft tissue attached to create flaps and permit later approximation in the midline. It is usually not necessary to perform a second incision at the shoulder to release the pectoral muscle insertion. Following debridement and muscle elevation, pulse lavage the entire surgical site with an adequate volume of saline with antibiotics. 4 Measure sternal edges Instrument 319.11 Depth Gauge Using the depth gauge, measure the sternal edges adjacent to each rib where a plate...

 Open the catalog to page 9
Titanium Sternal Fixation System-10

Reduce sternum 398.903 Sternal Reduction Forceps, angled, with teeth 398.985 Bone Reduction Forceps, large Reduce the sternum using reduction forceps on both the superior and inferior aspects of the sternum. When placing the forceps, care should be taken to avoid the intercostal and mammary vessels and nerves. Alternative instrument 398.902 Sternal Reduction Forceps Note: Sternum can also be reduced with stainless steel surgical wire, if desired. Precaution: Avoid direct contact of stainless steel wires with titanium implants to avoid galvanic corrosion. 6 Cut and contour template Instruments...

 Open the catalog to page 10
Titanium Sternal Fixation System-11

Surgical Technique 7 Select plate Instrument 319.990 Plate and Rod Cutter Select the appropriate length titanium sternal locking plate. Center the release pin on the sternum with sufficient plate length on each side to allow a minimum of four locking screws on each side. The plate can be cut to length, if necessary, using the plate and rod cutter. Alternative instrument 391.967* Shortcut Plate Cutter (2 required) As an alternative, shortcut plate cutters may be used. Note: All steps of preparation and implantation of the Sternal Locking Plate have to be done, whenever possible, with the assembled...

 Open the catalog to page 11

Archived catalogs

  1. Power line II

    4  Pages

  2. Concorde

    28  Pages

  3. LCP Intercarpal

    31  Pages

  4. Synthes TPLO.

    8  Pages

  5. CONDUIT™

    15  Pages

  6. DePuy Synthes

    81  Pages

  7. Anspach

    3  Pages

  8. Corail

    24  Pages

  9. Speed

    2  Pages

  10. attune

    80  Pages

  11. Polar

    4  Pages

  12. P F N A

    8  Pages

  13. DURALOC

    16  Pages

  14. MatrixNEURO

    8  Pages

  15. Anspach XMax

    4  Pages

  16. Air Pen Drive

    4  Pages

  17. Colibri II

    4  Pages

  18. Spine

    25  Pages

  19. TomoFix

    60  Pages

  20. Sacral Bars

    16  Pages

  21. Pelvic C-Clamp

    20  Pages

  22. LCP

    24  Pages

  23. PFNA

    112  Pages

  24. VA-LCP Elbow

    48  Pages

  25. Distal Radius

    44  Pages

  26. Olecranon

    30  Pages

  27. LCP Hook Plate

    28  Pages

  28. LCP S-A

    4  Pages

  29. Epoca

    4  Pages

  30. Philos

    32  Pages

  31. MultiLoc

    68  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.