BT077 BioTherm 14 Dry Ice PI

BT077 BioTherm 14 Dry Ice PI

BT077 BioTherm 14 Dry Ice PI

Product catalog summary
Assembly Components:
  • EPS 14 Lid (1 unit)
  • Dry Ice (8.5 kg)
  • Payload (1 unit)
  • EPS 14 Base (1 unit)
  • BioTherm 14 Outer (1 unit)

The mass of dry ice used in testing is detailed in section 2.2.

Conditioning Procedure:
  1. Prepare the payload according to specifications and ensure compliance with regulations if classified as dangerous goods.
  2. Pour approximately 0.9 kg of pelleted dry ice into the EPS 14 base.
  3. Place the payload on top of the dry ice.
  4. Pour the remaining dry ice into the EPS 14 base, ensuring the payload is fully surrounded.
  5. Securely fit the EPS 14 lid, ensuring the gasket engages.
  6. Close and secure the BioTherm 14 Outer lid and apply necessary shipping labels.

The BioTherm 14 Dry Ice is now ready for shipment.

Dry Ice Fill Guide:

The amount of dry ice required depends on the duration needed to maintain specific temperatures. An initial mass of 0.9 kg should be placed in the system before the payload for all durations.

Duration (hh:mm)Mass of Dry Ice Above Payload (kg)Recommended Total Mass of Dry Ice (kg)Remaining Payload Volume (L)
108:007.38.21.5
96:006.47.32.6
72:004.65.54.9

For maintaining -60°C:

Duration (hh:mm)Mass of Dry Ice Above Payload (kg)Recommended Total Mass of Dry Ice (kg)Remaining Payload Volume (L)
96:007.07.91.9
72:005.05.94.4
60:004.15.05.5

Dry ice fills are calculated using loss rates determined from qualification testing with an 8.5 kg fill.

See more

Catalog excerpts

BT077 BioTherm 14 Dry Ice PI-1

*Mass used in testing. See section 2.2 - Dry Ice Fill Guide for more information Qualification Report for BT077 BioTherm 14 Dry Ice vs ISTA 7D Profiles

 Open the catalog to page 1
BT077 BioTherm 14 Dry Ice PI-2

2.1.1 Prepare your payload according to specifications. If the payload is classed as dangerous goods, ensure it complies with regulations. 2.1.2 Pour approximately 0.9 kg pelleted dry ice (B) into the EPS 14 base (D). 2.1.4 Pour the remaining dry ice (B) (see section 2.2) into the EPS 14 base (D) ensuring the payload is fully surrounded with dry ice. 2.1.5 Close the system by securely fitting the EPS 14 lid (A), such that the gasket engages. 2.1.6 The BioTherm 14 Outer (E) lid can now be closed and secured. Apply the necessary shipping labels. Your BioTherm 14 Dry Ice is now ready to be shipped....

 Open the catalog to page 2