Catalog excerpts
DiaLP System DiaLP kits Legionella pneumophila for qualitative real-time PCR DiaLP is an in vitro test for rapid qualitative real-time PCR based detection of Legionella pneumophila (LP) in water and air samples. The kit is CE marked IVD approved diagnostic test validated against reference materials. The hygienic control of water, waste water, and air treatment systems is strictly regulated all around the world. LP is the most dangerous microbial contamination of water- and air treatment systems (waterworks, air condition devices etc.). DiaLP system is a test for the detection of pathogenic Legionella DNAs identical to those of the most frequently examined Legionella pneumophila strains. Test principle DiaLP reagent system is validated for qualitative diagnostics of Legionella pneu- mophila in clinical and air samples and can be used on any real-time PCR platform with minimum three channels. The primer-probe pairs included are specific to unique sequences encoding both the pathogenic mip factor gene and 16S rRNA of Legionella pneumophila. Detection of 5 GU/ml, genome equivalent chromosomal LP DNA per ml of sample The DiaLP kit is designed to amplify specific Legionella pneumophila 16S rRNA genomic sequences and mip gene together with regulatory elements to increase selection of functional active microbes with 99% specificity. Each kit contains DNA of reference material as positive control. • 2x Master Mix (buffer, dNTPs, fluorescent labelled primer-probe pairs) • Positive control DNA of reference material • Internal control • Product insert DiaLP kits are highly recommended for use with our DiaExtract Bacterial Cell Wash Solution (NED0020C) for the removal of non-viable cells and our DiaExtract Microbial DNA isolation kit (NED0010L) for highly pure DNA, free I^IAGON ^DiAGON* ^DiAGON* DiaLP 1 DiaLP ^gradewater Application tested on LightCycler® 1.5 and LightCycler® 2.0 (Roche® Applied Science). Test is adaptable to other platforms.
Open the catalog to page 1DiaLP System in the example of Legionella pneumophila, illustrated by the virulence factor encoding mip gene DiaLP real-time PCR test Agilent Mx3005P™ (Stratagene®) instrument Amplification Plots Standard Curve Initial Quantity (copies) SOUTH AMERICA DIAGON Ltda. - Brasil Av Jose Candido Da Silveira, 2100 Belo Honzonte, PT. Inti Diagontama Selaras - Indonesia Perkantoran Plaza Pasifik A3/59 Jl Raya Boulevard Barat Kelapa Gading Permal Jakarta 14250
Open the catalog to page 2All Diagon Ltd. catalogs and technical brochures
-
Blood Controls
2 Pages
-
Cellagon 3
3 Pages
-
Coag S
2 Pages
-
Coag 2D
2 Pages
-
Coag 4D
2 Pages
Archived catalogs
-
Coag M
2 Pages
-
Coag L
2 Pages
-
Coag XL
2 Pages
-
DiaMRSA System
2 Pages
-
Diagon Hematology
19 Pages
-
Diagon Control & Calibrators
2 Pages
-
Diagon Reagents
10 Pages
-
Diagon reagent kits
12 Pages
-
Coag s
2 Pages
-
D-Clot
2 Pages
-
Coag 4D
2 Pages
-
Dia-Timer 2 ; Dia-Timer 4
2 Pages
-
D-Cell 60
4 Pages