3d bak Body analysis kapture
Open the catalog to page 1
3D BAK BODY ANALYSIS KAPTURE paziente proval COBB: 3,17" | 3,74’ | 6,91" CITOSI / LordDSI: 45,66° I 4bJ Simultaneous acquisition with 1 (body symmetries), 2 (body symmetries , COLUMN 3D and skeleton) or 4 (body symmetries , COLUMN 3D, skeleton and muscle chains) high resolution cameras, OF THE STRUCTURAL MORPHOLOGY IN THE FRONTAL AND SAGITTAL PROJECTIONS. The analysis provides global «stick diagrams^, measuring inclinations, lenght and angles of the body, highlighting asymmetries (mm and degrees), rotations and deviations of the vertebral column and of the walk (with Image System Software...
Open the catalog to page 2
OPTOELECTRONICSTRUCTURAL AND ARTICULAR SYMMETRIES Hi-Res autocalibrating cameras to PRECISELY MONITOR PATIENT’S STRUCTURAL morphology on Frontal (A/P) and Sagittal (R/L) planes MEASUREMENTS • Strusctural symmetries • Ariticular rotation and vertebral column deviation • Muscle chains
Open the catalog to page 3
BPi REPORTNORMAL VALUES Values are evaluated through B.P.I. Biomechanical Postural Index scale (0= PHYSIOLOGICAL / 3= SEVERE), ANALYZED FOR SINGLE “ITEM” OR SINGLE WHOLE VIEW. 3DBAKVer 0.0.7 FRONTALE ANTERIORE IBPs /Til Simmetria Bipupilare Simmetria bpalle smnetna pemca SimrretriaN'aileo are Simmetria Cramca (filo a piombo) 5«m*netria Strutturaie Anterior? |flo a piombo} Angolo Rotuleo Desrro Angolo Rotuleo Sinistra Simmetria Braccia FRONTALE POSTERIORE IBPs #9 Appiombo Colonna Dorsale Simmetra Spollc Simmctrio Scopolore Simmctrio Ciote iliaihe Simmctrio SIPS AppioniLro Culaimd Lombdie...
Open the catalog to page 4
3D OPTOELETTRONIC A REVOLUTIONARY 3D SKELETON RECONSTRUCTION OF THE BODY 3D BAK - TEST COBB: 7,17° | 7,17° Citosl / Lordosi: 57,25° | 40,65° A THREE-DIMENSIONAL PROCESSING INSTANTLY RECONSTRUCTS ON THE ANALYZED IMAGES THE SKELETAL STRUCTURE FOR EACH PROJECTION. The numerical information ALLOW TO QUANTIFY STRUCTURAL MISALIGNMENT AND DEVIATIONS OF THE COLUMN IN COBB DEGREES, PROVIDING AUTOMATICALLY ALSO THE ROTATION OF THE INDIVIDUAL VERTEBRAE, THE LENGTH AND THE ROTATION OF THE LOWER LIMBS. D8 rotazione = ( D9 rotazione = t 010 rotazione = D11 rotazione = D12 rotazione = SaciMm LI rotazione...
Open the catalog to page 5
REPORT PRINT OUT Nome paziente Patient name
Open the catalog to page 6
x-ray Comparison PERFECT OVER IMPOSABLE TO X-RAY IMAGE THAT ALLOWS TO DRASTICALLY REDUCE THE RADIOGRAPHIC CONTROLS On 936 performed exams 897 = 95.8% Results perfectly corresponding to X-Rays
Open the catalog to page 7
Conclusions THE TEST WITH VARIOUS WEDGES IT SEEMS TO BE TOLERATED ONLY THE 4 MM. THE DISCREPANCY BETWEEN THE REAL NEED (2 CM) BY PRESCRIPTION) AND THE 2,5 CM, 1 CM OR 2 CM - THAT INCREASE THE COBB DEGREES - CAN BE TRACED TO THE FACT THAT ACCORDING TO THE THEORY OF POSTURAL REPROGRAMMING, THE HUMAN SYSTEM AS A COMPLEX SYSTEM IS NOT A LINEAR BUT COMPLEX. Without wedge P. Galasso, R. Schiffer from ‘’Atlante Postura e Riabilitazione’’ Wedge of 0,4 on right Cobb 1: 7,4° Cobb 2: 11,9° Cobb 3: 12,8°
Open the catalog to page 8
Diasu Health Technologies Sa.Ni Corporate s.r.l. Via Giacomo Peroni 400/402 00131 Roma, Italia +39 06 85 37 141 www.diasu.com info@diasu.com
Open the catalog to page 9All Diasu Health Technologies catalogs and technical brochures
-
WALK PRESSURE ANALYSIS LAB
6 Pages
-
HANDYART 3D
4 Pages
-
MAIN PRODUCTS CATALOGUE
16 Pages
-
Diasu Pressure Runner
5 Pages
-
PLANTARCAM
6 Pages
-
3D PODOSCANALYZER
7 Pages
Archived catalogs
-
Targeted postural assessment
4 Pages