ULTRASENSOR 3D PLATFORM WITH 7 SENSORS CM2
Open the catalog to page 1Ultrasensor 3d A PATENTED PLATFORM, HAVING LARGE SURFACE AND HIGH RESOLUTION, DESIGNED TO ALLOW, THANKS TO A SPONTANEOUS AMBULATION OF THE PATIENT, A PRECISE ANALYSIS OF THE FOOT PRESSURE WHILE WALKING. . ENTRY AND EXIT WALKWAYS WITH SLIPWAY TO FACILITATE PATIENT’S AMBULATION. AN EXPANDABLE TECHNOLOGY UP TO 4 METERS IN LENGTH AND UP TO 262.144 SENSORS, THANKS TO AN ACQUISITION SURFACE OF 7 SENSORS EACH CM2. The only platform with 7 sensors each cm2
Open the catalog to page 2UltraSensor Baropodometer Platform is available: POSTURAL (cm 50x50) - DUAL TRANSPORTABLE (cm 100x50) WALK (cm 200x50) - SPORT (cm 300x50) Platform is also available as Diagnostic model in the following versions: The new generation of pressure platforms
Open the catalog to page 3Ultrasensor 3d N O LATERAL ELEVATION AT THE EDGES OF THE PLATFORM, TO AVOID UNCERTAINTY DURING THE TEST EXPANSION ACQUISITION SURFACE IN LENGTH IN ORDER TO STANDARDIZE THE GAIT CYCLE ENLARGEMENT OF THE SURFACE IN WIDTH AT 1 METER FOR A PERFECTLY SPONTANEOUS DIAGNOSTIC TEST RESOLUTION 7 SENSORS PER CM2, THE HIGHEST IN THE WORLD, TO SEE THE REAL THREE-DIMENSIONALITY OF THE FOOT Patented to overcome the constraints of all existing platforms
Open the catalog to page 4LABORATORY OF WALK PRESSURE ANALYSIS (LAC) It allows to detect data of spontaneous walking WITHOUT ENVIRONMENTAL INFLUENCES. CONTEMPORARY RECORDING OF PATIENT MORPHOLOGICAL DATA FROM STATIONARY AND WALKING THROUGH HIGH-RESOLUTION CAMERAS (BODY MORPHOMETRY) AND A HIGH-SPEED SCANNER (foot morphometry)
Open the catalog to page 5LAC I System Divisione di Podologia Clinica e Diabetologica OSPEDALE I.D.I. ROMA (Italia) LAC I (LABORATORY FOR STEP ANALYSIS), MADE WITH 8 PLATFORMS ULTRASENSOR ON AN AREA OF 2 MT X 1 MT, IS THE TECHNOLOGICAL ADVANCEMENT OF THE PREVIOUS PLATFORM "WALK AT 4 SENSORS" TO STUDY THE CHARACTERISTICS OF THE GAIT CYCLE IN ANY PATIENT, PERMITTED BY THE WIDTH OF THE PLATFORM AND ALLOWS THE STUDY OF FOOT INSTABILITY IN STANDING UPRIGHT POSTURE OR DYNAMIC (STEP TEST). (STATIC TEST AND STABILOMETRY) THE "ANALYSIS OF STEP PRESSURE INDEX" IS A DIAGNOSTIC MEASUREMENT AT THE BASE THERE IS AN AMBULATORY TEST...
Open the catalog to page 6LAC System Department of Rehabilitation VITERBO HOSPITAL (Italy) LAC III-V (LABORATORY FOR WALK ANALYSIS) ARE THE "TOP OF CONFIGURATION” WITH 10/16 ULTRASENSOR INTERCONNECTED PLATFORMS TO STUDY THE CHARACTERISTICS OF THE PRESSURE FOOT WITH SPECIFIC GAIT PARAMETERS, ALLOWED BY THE LENGTH OF THE PLATFORM (UP TO 4X1), STUDY THAT SHOWED STRUCTURAL ABNORMALITIES SUPRA-SEGMENTAL MILD OR SEVERE FROM A STANDING UPRIGHT POSITION (TEST STABILOMETRY) OR DYNAMIC (THE PRESSURE INDEX WAY TEST), AS WELL AS VALUES FOR THE RISK OF FALLING. THE "ANALYSIS OF PRESSURE INDEX" WAY IS A DIAGNOSTIC MEASUREMENT AT THE...
Open the catalog to page 7Biometrics software Automatic area division THE IMPRESSIVE RESOLUTION, VISIBLE IN REAL TIME DURING ACQUISITION, HELPS DIAGNOSIS AND PERMIT AN AUTOMATIC ANALYSIS OF THE WHOLE FOOT’S DATA (PERIMETER, REARFOOT / MIDFOOT / HINDFOOT / TOES MEDIAL AND LATERAL SURFACES/ LOAD, ANGLES, ETC), COMPARING STATIC WITH DYNAMIC AND PODOSCOPE MORPHOMETRY. Autolearning software for a 3D automatic detection of the entire plantar surface 3D in high resolution on real time Sport platform 50 cm acquisition
Open the catalog to page 8RISULTATI OSCILLAZIONE CONFRONTO OUALITATIVO Elaborazione descrittiva aulomatica del dati : La valutazione biometrica prcssoria Dinamica e un'indagine che pcrmette di studiare I'appoggio del soggetto a seguilo di esecuzione di un ciclo del pas so su pedana baropodometrica. attraverso il quale o elaborata l'impronta media che quantifica numericamenle i parametri del cammlno. L'osservazione di questi valori consente di studiare le variazioni Ira i singoli appoggi. per definire instability deambulatorie e relative dispendio energetico. non che valutare le modificazioni osservate rispetto ai parametri...
Open the catalog to page 9Supported operating systems Windows >7® (64-bit) Maximum power consumption 0,1 A - Data interface USB 2.0 internal or external Scan frequency Min: 30 fps on real time Max: 400 fps Power Supply 18v (medical grade conform to EN-60601-1 and EN-60601-1-2 Norms) Dimensions Single Module 15(h) x 50(w) x 50(l) cm Sensor type Hi restive sensor active matrix gold plated dimension 3,9 mm each Sensor conformity IO11-I=12 (gold quality, hole diameter, electrical test). Sensor check made in AQL 0.65 compliance Life 10 years (minimum) Operating acquisition surface Lenght Min: 50 cm Lenght Max Suggested:...
Open the catalog to page 10Diasu Health Technologies Sa.Ni Corporate s.r.l. Via Giacomo Peroni 400/402 00131 Roma, Italia +39 06 85 37 141 www.diasu.com [email protected]