CRP U-hs

CRP U-hs

CRP U-hs

Product catalog summary
Product Overview:
DiaSys offers a versatile reagent kit, CRP U-hs, suitable for both universal and high-sensitive applications. It is designed for use on various automated systems, including DiaSys respons®, BioMajesty® JCA-BM6010/C, Hitachi 911, Hitachi 917, and Vitalab Selectra.

Specifications:
  • Dynamic range: 0.3 – 350 mg/L
  • High sensitive range: 0.05 – 20 mg/L
  • Prozone safety up to 1000 mg/L
  • No dilution steps required
  • High on-board and calibration stability
  • No interference from lipids, hemolysis, bilirubin, and RF

Clinical Significance:
C-reactive protein (CRP) is a key acute-phase protein, with levels increasing in response to inflammation. It is used to detect acute infections and monitor inflammatory processes, offering more sensitivity and specificity than ESR and leukocyte count. Elevated CRP levels can indicate a risk for coronary heart disease (CHD).

Performance and Comparison:
  • Excellent precision across the range, especially at lower ends
  • Good correlation with nephelometric methods
  • Reliable controls with four different levels
  • Calibrators standardized to International Reference Material ERM®-DA470

Reference Ranges:
  • Adults: < 5 mg/L
  • Values > 1 mg/L may indicate CHD risk

Product Components:
  • Calibrator set for universal range: 5 x 1 mL TruCal CRP U
  • Controls for universal range: TruLab CRP Level 1 and 2, TruLab Protein Level 1 and 2
  • Calibrator set for high sensitive range: 5 x 1 mL TruCal CRP hs
  • Controls for high sensitive range: TruLab CRP hs Level 1 and 2

Contact Information:
DiaSys Diagnostic Systems GmbH, Alte Strasse 9, 65558 Holzheim, Germany. Phone: +49 (0) 64 32 /91 46-0, Fax: +49 (0) 64 32 /91 46-32, Email: [email protected], Website: www.diasys-diagnostics.com
See more

Catalog excerpts

CRP U-hs-1

CRP U-hs universal and high sensitive CRP U-hs cat. no. DiaSys offers reagent kits for manual use, for use on DiaSys respons® (full barcode), BioMajesty®JCA-BM6010/C (full barcode) and for use on other automated systems like Hitachi 911, Hitachi 917 (full barcode) and for Vitalab Selectra. Detailed information is available on our website or in our product catalogue. calibrator set for universal range (5 levels) 1 7040 99 10 059 TruLab Protein Level 1 TruLab Protein Level 2 calibrator set for high sensitive range (5 levels) 1 7080 99 10 059 controls for high sensitive range 5 9730 99 10 046 :: One reagent for all your needs :: Dynamic range 0.3 – 350 mg/L :: High sensitive range 0.05 – 20 mg/L DiaSys Diagnostic Systems GmbH

 Open the catalog to page 1
CRP U-hs-2

Excellent precision over the whole range (Hitachi 911) Universal range Clinical interpretation High sensitive range C-reactive protein (CRP) is the best known among the acute-phase proteins, a group of proteins whose concentration increases in blood as a response to inflammatory disorders (acute-phase response). CRP is normally present in low concentration in blood of healthy individuals (< 5 mg/L). It is elevated in acute inflammatory processes associated with bacterial infections, post-operative conditions or tissue damage already after 6 hours reaching a peak at 48 hours. Measurement of CRP...

 Open the catalog to page 2
CRP U-hs-3

Excellent precision over the whole range (Hitachi 911) Universal range Clinical interpretation High sensitive range C-reactive protein (CRP) is the best known among the acute-phase proteins, a group of proteins whose concentration increases in blood as a response to inflammatory disorders (acute-phase response). CRP is normally present in low concentration in blood of healthy individuals (< 5 mg/L). It is elevated in acute inflammatory processes associated with bacterial infections, post-operative conditions or tissue damage already after 6 hours reaching a peak at 48 hours. Measurement of CRP...

 Open the catalog to page 3
CRP U-hs-4

CRP U-hs universal and high sensitive CRP U-hs cat. no. DiaSys offers reagent kits for manual use, for use on DiaSys respons® (full barcode), BioMajesty®JCA-BM6010/C (full barcode) and for use on other automated systems like Hitachi 911, Hitachi 917 (full barcode) and for Vitalab Selectra. Detailed information is available on our website or in our product catalogue. calibrator set for universal range (5 levels) 1 7040 99 10 059 TruLab Protein Level 1 TruLab Protein Level 2 calibrator set for high sensitive range (5 levels) 1 7080 99 10 059 controls for high sensitive range 5 9730 99 10 046 ::...

 Open the catalog to page 4

All DiaSys Diagnostic Systems GmbH catalogs and technical brochures

  1. respons®910

    4  Pages

  2. DiaSys

    104  Pages

  3. HbA1c net FS

    6  Pages

  4. InnovaStar®

    6  Pages

  5. respons®920

    4  Pages

  6. Cystatin C FS

    4  Pages

  7. Electrolytes

    4  Pages

  8. D-Dimer FS

    4  Pages

  9. oneHbA1c FS

    4  Pages

  10. Lactate FS

    2  Pages

  11. Prealbumin FS

    2  Pages

  12. LP-PLA2

    4  Pages

  13. Ethanol FS

    2  Pages

  14. CRP FS

    4  Pages

  15. CK-MB FS

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.