ING CubeTrack - 1

walk-away system ' THE SMART FOR ERYTHROCYTE SEDIMENTATION RATE COMPLETE AUTOMATION TECHNICAL CHARACTERISTICS CURRENT ABSORBED ELECTRIC POWER FUSE BLOCK DIMENSIONS WEIGHT ROOM TEMPERATURE ALLOWABLE RELATIVE HUMIDITY CENTRAL UNIT DISPLAY CONTROL UNIT PERIPHERALS INTERNAL ANALYTIC SECTION OPTIC GROUPS PRINTER INTERFACE PROTECTION CATEGORY SECURITY OF THE DEVICE EMC INSTALLATION CATEGORY CATALOG NUMBER Europe 230Vac@50Hz, Usa/Canada 110-120Vac@60Hz 265VA 2 x 5.0 AT (Delayed) (5 x 20 mm) UL 650 x 570 x 690 mm ( l x h x d ) 60 Kg In exercise from +15 to +35°C, Warehouse up to 45°C From 20% to 80% without condensation Microprocessor Intel XScale PXA 255 32 MB; FLASH 64MB SDRAM TFT 800x 600 colour with Touch Screen Microprocessor card on owner bus 89 position chain for the appropriate test tube Two couples of optic-electronic elements (Led & analogical sensor) Alphanumeric with thermal paper wide 58mm, 36 characters per line, speed 20mm/sec. 2 x RS232C, 2 USB Host, 1 USB Client, 1 Slot Compact Flash CLASS I EN61010-1 EN61326-1 II 10380 CONSUMABLES & CHECK DEVICE TRANSPONDER RF (Dedicated tube with trasponder RF to be used to charge the VES-Matic Cube System with the exact number of tests) 10.000 tests 5.000 tests 1.000 tests ESR CONTROL CUBE 4 x 9 mL 2 x 9 mL Normal - 2 x 9 mL Abnormal ESR CONTROL CUBE 2 x 9 mL 1 x 9 mL Normal - 1 x 9 mL Abnormal niECCE DIESSE Diagnostica Senese SpA Via del Pozzo, 5 Loc. San Martino 53035 Monteriggioni (SI) Italy Tel: +39 0577 319560/61 Fax: +39 0577 318763 www.diesse.it salesoffice@diesse.it UICOOC DIAGNOSTIC SYSTEMS

Open the catalog to page 1
ING CubeTrack - 2

TOTAL INTEGRATION IN LABORATORY AUTOMATION SYSTEMS Enables the VES-MATIC CUBE TRACK to be easily integrated into any laboratory automation system OPEN SOFTWARE COMPLETE TRACEABILITY / The level of erythrocyte sedimentation is determined directly In closed top NO lavender tubes DEDICATED TUBES Can process any kind of top lavender tubes SIMULTANEOUSLY RESULTS expressed as mm/h according to the Westergren Reference Method (sedimentation in citrate) of the samples in any moment of the testing process NO PRODUCTION OF LIQUID WASTE • Complete safety for the operator • No extra costs for the...

Open the catalog to page 2

All Diesse Diagnostica Senese catalogs and technical brochures

  1. RackSmart

    2 Pages

  2. Cube 200

    2 Pages

  3. Cube 80

    2 Pages

  4. MINI-CUBE

    2 Pages

  5. ChorusTrio

    2 Pages

  6. AUTODAT

    2 Pages

  7. ESR Line

    2 Pages

  8. CUBE30touch

    2 Pages

  9. Chorus Line

    2 Pages

  10. VACU-CODE

    2 Pages

  11. Catalog 2017

    54 Pages

  12. VES-MATIC 30

    2 Pages

  13. VES-MATIC 20

    2 Pages