1. Catalogs
  2. DLAB Scientific Co., Ltd.
  3. Real-Time PCR System Accurate 96
video corpo

Real-Time PCR System Accurate 96

Real-Time PCR System Accurate 96

Real-Time PCR System Accurate 96

Product catalog summary
Overview: The DLAB Accurate 96 Real-Time PCR System is a sophisticated device designed for multiplex PCR, capable of detecting up to six fluorescence channels simultaneously. It is suitable for various applications including clinical diagnostics, forensic analysis, and quality testing.
Key Features:
  • Supports detection of five target genes across 96 samples.
  • Utilizes Fresnel lens optical signal acquisition and time-resolved signal separation technologies.
  • Ensures high sensitivity, temperature uniformity, and accuracy.
Technical Innovations:
  • Reduces multi-color crosstalk and edge effects without requiring ROX correction.
  • Features a new optical signal detection system for high repeatability.
  • Innovative scanning methods enhance accuracy and reduce fluorescence crosstalk.
  • Temperature accuracy and uniformity are maintained at ±0.2°C.
Performance:
  • High sensitivity and resolution with a unique optical scanning detection system.
  • Temperature uniformity difference is less than ±0.2°C at 81°C.
  • Capable of distinguishing 1.33-fold copy number differences in single-plex qPCR.
Applications:
  • Clinical diagnostics, including swine fever virus detection.
  • Forensic applications such as paternity testing and identification.
  • Quality and safety testing in food and public health sectors.
Technical Parameters:
  • Sample capacity: 96-well plate.
  • Reaction volume: 10-50 μl.
  • Temperature range: 4 – 100 °C with a maximum heating/cooling rate of 6.0°C/s.
  • Fluorescent channels: 4/6 channels with a dynamic range of 10 orders of magnitude copies.
Contact Information: For further inquiries, contact DLAB Scientific Inc. at [email protected] or visit their website at www.dlabsci.com.
See more

Catalog excerpts

Real-Time PCR System Accurate 96-2

Real-Time PCR System DLAB Accurate 96 is based on global vision of product design concepts and manufacturing processes. It creatively combines Fresnel lens optical signal acquisition technology, time-resolved signal separation technology and unique temperature control technology. And it reaches international advanced level in sensitivity, multi-color crosstalk, temperature uniformity and accuracy. It supports the application of all common QPCR Up to 6 fluorescence detection channels allowing multiplex PCR ――Simultaneous detection of 5 target genes in 96 samples Channel 6 Simultaneous scanning...

 Open the catalog to page 2
Real-Time PCR System Accurate 96-3

Real-Time PCR System Technical Innovation 1 ――Effectively reduce multi-color crosstalk and edge effect, no ROX correction required The multi-color crosstalk caused by the small sample spacing of 96 or 384-well plates has a great influence on the accuracy of the experimental results, especially in multiplex qPCR detection. The new optical signal detection system and unique time-resolved scanning can reduce non-target sample optical signal collection. Thereby high repeatability of single fluorescent channel can be ensured. Four different target genes (2 repeats) of FAM/HEX/ROX/Cy5 were simultaneously...

 Open the catalog to page 3
Real-Time PCR System Accurate 96-4

Real-Time PCR System Innovative scanning method and time-resolved signal separation technology――High accuracy • Unique time-resolved scanning method ᅠ The different fluorescence signals of the same sample are collected at different times. ᅠ The high-speed stepping motor and the highly sensitive detector ensure that all signal acquisition of the entire • Innovative detection channel arrangement Interlaced arrangement of upper and lower channels further reduces inter-hole and multi-color fluorescence crosstalk. • Double FAM scanning for melting curve Scan time is shortened a lot. sample plate is...

 Open the catalog to page 4
Real-Time PCR System Accurate 96-5

The Tm values of 96 replicate wells were detected. The results showed that the temperature uniformity difference was <±0.2℃@81℃. Temperature profile of 96-well plate Tm value normal distribution map of 96-well plate Normal distribution The melting curves of 48 replicate s

 Open the catalog to page 5
Real-Time PCR System Accurate 96-6

Real-Time PCR System User-friendly software International professional design team guarantee The software can provide you with a full range of high quality and excellent performance of each solutions for sample detection and result analysis. One-stop process and solution Sample preparation and nucleic acid extraction Data analysis QPCR detection

 Open the catalog to page 6
Real-Time PCR System Accurate 96-7

Real-Time PCR System Classic Examples ――Swine fever virus ASFV detection QPCR was used to detect the swine fever virus DNA in vitro for clinical diagnosis of suspected diseased pigs. Kit:Swine fever virus (ASFV) nucleic acid detection kit(PCR probe assay)、DNA extraction kit(Spin column method) Method: 5 mL of blood was extract from a live pig syringe to be examined. DNA was extracted by DNA extraction kit. According to the ASFV detection kit operation method, the extracted DNA, the positive control substance, and the negative control substance is separately added to the PCR reaction solution...

 Open the catalog to page 7
Real-Time PCR System Accurate 96-8

Rotary Evaporators | Accessories DLAB Scientific Inc. Add: 775 Rivera St, Riverside, CA 92501, USA Tel: +1- 747- 230-5179 Fax: +1-909-230-5275 E-mail: [email protected] Service contact: [email protected] web: www.dlabsci.com

 Open the catalog to page 8

All DLAB Scientific Co., Ltd. catalogs and technical brochures

  1. Catalogue

    119  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.