1. Catalogs
  2. Double Medical Technology
  3. VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate

VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate

VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate

VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate

Product catalog summary
Product Features
  • Low-profile design to minimize soft tissue irritation.
  • Anatomically optimized plate geometry for varying patient statures and clavicular lengths/curvatures.
  • Patented variable-angle mechanism allowing up to 15° angular locking.
  • Compatible with variable-angle locking and compression fixation for angular stability and dynamic compression.
  • Universal 2.7mm screw compatibility for simplified surgical instrumentation.
Indications
  • Clavicle fractures (shaft and distal).
  • Clavicle osteotomy.
  • Malunion or nonunion of the clavicle.
Contraindications
  • Active infection or osteomyelitis.
  • Severe osteoporosis where sufficient fixation cannot be achieved.
  • Allergy to implant materials (titanium alloy).
  • Patients unfit for surgery or anesthesia.
  • Skeletally immature patients with open growth plates.
Product Information
  • Distal Lateral VA Clavicle Plate and VA Clavicle Shaft Locking Plate available in various lengths and hole configurations.
  • 2.7mm Cortex Screw and VAL 2.7mm Locking Screw available in multiple lengths.
Manufacturer Information

Double Medical Technology Inc., Xiamen, Fujian, China. Contact via phone, email, or website for more information.

Usage Restrictions

This document is for internal reference and training purposes only. Unauthorized dissemination or use beyond approved indications is prohibited.

See more

Catalog excerpts

VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate-1

VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate recycle

 Open the catalog to page 1
VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate-2

VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate Product Features - Low-profile design to minimize soft tissue irritation. - Anatomical optimized plate geometry to accomodate varying patient stature and different clavicular lengths and curvatures. - Patented variable-angle mechanism enabling up to 15° angular locking. - Compatible with variable-angle locking and compression fixation to combine angular stability and dynamic compression. - Universal 2.7mm screw compatibility to simplify surgical instrumentation. - Clavicle fractures (shaft and distal) - Clavicle osteotomy - Malunion...

 Open the catalog to page 2
VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate-3

DOUBLE MEDICAL ■ Product Information ■ Distal Lateral VA Clavicle Plate Code Length (mm) holes ■ VA Clavicle Shaft Locking Plate Code Length (mm) holes

 Open the catalog to page 3
VA Clavicle Shaft Locking Plate Distal Lateral VA Clavicle Plate-4

DOUBLE MEDICAL ■ 2.7mm Locking Screw, CoCrMo MEDICAL TECHNOLOGY INC No. 18, Shanbianhong East Road, Haicang District, Tel: +86 592 6087101 Fax: +86 592 6587078 * 361026, Xiamen, Fujian, PEOPLE'S REPUBLIC OF CHINA E-mail: [email protected] Website: www.doublemedicalgp.com This document is intended for internal reference and use only and is for internal training purposes only. For prohibited contents or precautions, please refer to the instructions. The information contained in this document is not intended in any way to solicit product investment, publicity or promotion, or to use any product...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.