Catalog excerpts

i214-1

i214 ionia™ Analog I/O Module Data Sheet The i214 is a high-precision analog interface module for the ionia™ product family. The i214 is designed for harsh rolling stock environments and is fully compliant to EN 50155:2007.

 Open the catalog to page 1
i214-2

duagon Data Sheet Preamble On having purchased products described in this data sheet, the customer acquires the right to use the products according to its specified purpose and in accordance with all operation, service and maintenance instructions. All other rights to the product, duagon's intangible assets rights in particular, belong solely to duagon and may not be deemed to have been assigned along with the sale of the products. All product properties are fully described in the data sheet under express exclusion of any warranty for other properties. Of decisive relevance is the data sheet...

 Open the catalog to page 2
i214-3

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 3/27

 Open the catalog to page 3
i214-4

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 4/27

 Open the catalog to page 4
i214-5

1. General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or those connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform installation, maintenance and service procedures To avoid fire or personal injury Connect and disconnect properly. This data sheet contains all relevant information for connecting the device. Power On only with all connections made. All connectors on the device must be connected (unused connections should be covered with a dummy connector). Ground the...

 Open the catalog to page 5
i214-6

2. Introduction The i214 is an intelligent high-precision analog interface module for the ionia™ system. The module has 3 analog outputs and 6 analog inputs. The analog output group and the analog input group are galvanically isolated from each other, each group having its own reference ground. Additionally, there is an isolated power supply output, which can be used to power external devices. Each input and output can be selected as voltage or current input/output via software. All configuration registers and the input values are accessible by a fast and secure point to point connection from...

 Open the catalog to page 6
i214-7

Figure 1 "Hardware Structure" shows the i214 hardware structure as a reference. The module provides the following interfaces: • Front panel connectors: o X1: Auxiliary power output connector o X2: Analog output connector o X3: Analog input connector Figure 2 Basic Function Blocks © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 7/27

 Open the catalog to page 7
i214-8

There are three different function groups available on the i214: • Auxiliary power supply Each of the groups features its own reference ground. The soft-core controller manages the operation of the analog outputs and inputs and communicates with the ionia™ using direct connection over the Backplane. The device is supplied with power from the Backplane and it contains necessary circuitry to maintain operation during power interruptions (the S2 capacitors). © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 8/27

 Open the catalog to page 8
i214-9

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 9/27

 Open the catalog to page 9
i214-10

Table 3 Analog Input Connector Pinout The pinout is specified in a way, that if 6 analog inputs are assembled, pin1 may form a twisted pair with pin 7 (AI_GND) and pin 2 may form a twisted pair with pin 3 (AI_REF). Twisted pairs which consist of an analog input line and AI_GND are especially optimized for current measurements, whereas pairs consisting of an analog input line and AI_REF are optimized for voltage measurements. Please note: AI_GND and AI_REF must be shorted on the counterpart side for accurate measurements. © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released:...

 Open the catalog to page 10
i214-11

Euogon_4.5. Backplane (X4) CAUTION. The backplane interface is intended for internal backplane connection ZyK inside ionia™ system. Any other use my lead to malfunction or damage of ionia™ / « \ system. The pinout of the connector is provided for reference only. Table 5 Pinout definition for the JTAG interface (X5) © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 11/27

 Open the catalog to page 11
i214-12

0uagon*_5. Software5.1. Programming The module is programmable by the central processing unit using a comfortable programming environment, that is based in IEC 61131 LD, FBD, ST, IL or SFC or via plain C. • "ionia™ Get Started Documentation", d-007724-nnnnnn and Firmware update is handled by the central processing unit (see i101/102/103 for further information). Thanks to a flash memory, that stores a backup firmware image, the i204 module is power-fail-safe during a firmware update process. The ionia™ system uses a 100Mbit/s duagon star slave (DSS) backplane communication infrastructure. Each...

 Open the catalog to page 12
i214-13

Ta =-40°C...+85°C, typical values for Ta = 25°C (unless otherwise specified). © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 13/27

 Open the catalog to page 13
i214-14

Table 10 Power Supply Output Operating Conditions © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 14/27

 Open the catalog to page 14
i214-15

Table 11 Dimensions and weight of the i214 © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 15/27

 Open the catalog to page 15
i214-16

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 16/27

 Open the catalog to page 16
i214-17

Table 14 Material listing for fire and smoke impact estimation Note: Total mass of not classified components (non-metallic and without UL94V-0 classification) is 58g. © duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 2018-12-07 / Otero Page 17/27

 Open the catalog to page 17

All Duagon Germany GmbH catalogs and technical brochures

  1. D015M

    2  Pages

  2. PX1N

    4  Pages

  3. D217

    2  Pages

  4. D215

    2  Pages

  5. D153E

    5  Pages

  6. D135EML

    2  Pages

  7. D134E

    2  Pages

  8. D114RS

    2  Pages

  9. D114L

    2  Pages

  10. D113

    2  Pages

  11. D023E

    4  Pages

  12. D017M

    2  Pages

  13. D015M

    2  Pages

  14. D015E

    2  Pages

  15. D013

    2  Pages

  16. i012

    26  Pages

  17. i303

    21  Pages

  18. BL72E

    6  Pages

  19. D501

    5  Pages

  20. G240

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.