Data Logger Systems
20Pages

{{requestButtons}}

Catalog excerpts

Data Logger Systems - 1

Data Logger Systems FOR THERMAL PROCESS VALIDATION Washer-disinfectors and washer-disinfectors for endoscopes Transport and storage monitoring for sterile utilities Steam and gas sterilizers Bed pan washer DAC Un

Open the catalog to page 1
Data Logger Systems - 2

Easy and reliable routine control and validation Validation Reproducible test that a process permanently generates the required results. Validation is a clear evidence that procedures, processes, equipment items, materials or systems actually cause the expected results. Routine control Routine control is a periodical test to determine the performance of the equipment. It is the verification that the limits are in accordance to the validation. The frequency depends on device and process. Requirement for reprocessing of medical devices Reprocessing of medical devices coming to an intended...

Open the catalog to page 2
Data Logger Systems - 3

Data Logger Systems Made in Germany Our data loggers offer ways to validate many different thermal processes in the medical, pharmaceutical and food sector. An independent routine control is also possible. Medical Sector • Steam sterilizers Ethylene oxide • Blood banks • Medicine refrigerators jsses with temperature a Pharmaceutical Sector • Steam sterilizers • Stability chambers • Cold storage • Validation of store houses • Medicine refrigerators d pressure data loggers Food Sector • Transport facilities • Full water autoclaves Our systems are compliant with the relevant standards and...

Open the catalog to page 3
Data Logger Systems - 4

Validation sets and routine control sets Due to the different requirements for routine control and validation processes, there are differently compiled sets at ebro. The applications for the different sets are clearly displayed in the table below. So it is possible to choose the suitable set for your application at a glance. Washer disinfector Washer disinfector for endoscopes Part No. Routine control in Bed pan washer Validation of processes in Washer disinfector Washer disinfector for endoscopes SL 1010 Temperature data logger set Independent routine control in bed pan washers according...

Open the catalog to page 4
Data Logger Systems - 5

SL 1110 Temperature- / Pressure data logger set Independent routine control in washer disinfectors and washer disinfectors for endoscopes (ISO 15883) as well as steam sterilizers (ISO 17665) Easy to use set for temperature and pressure control in washer disinfectors and sterilizers. Determine of pH- or conductivity values of the cleaning phase or disinfection phase in washer disinfectors. Determine of conductivity in feed water of sterilizers. Characteristics: • Automatic calculation of the A0-values • Calculation of the F value • Calculation of the saturated steam temperature • Generation...

Open the catalog to page 5
Data Logger Systems - 6

SL 1620 EBI 16 Routine control set Electronic Bowie&Dick-Test system for steam sterilizers and a temperature- / pressure data logger for routine control For the realization of Bowie&Dick-Test or the vacuum test in accordance with the standards EN 285 und ISO 17665 and routine control in washer disinfectors and washer disinfectors for endoscopes (ISO 15883) as well as steam sterilizers (ISO 17665). EBI 16 is certified according to EN ISO 11140-4. Characteristics: • Calculation of the F0-value • For small and large sterilizers • Routine control in washer disin- • Calculation of the saturated...

Open the catalog to page 6
Data Logger Systems - 7

SL 3000 Complete validation set small sterilizer Validation of processes in small steam sterilizers according ISO 17665 Characteristics: • For sterilizers according ISO 13060 (small steam sterilizer) • Calculation of the F0 value • Calculation of the saturated steam temperature • Generation of reports with clear result The set contains: • 1 x EBI 10-TP453 temperature/pressure data logger with silicon protection box AL 101 • 1 x 4-port Interface EBI IF 200 with USB connection and antenna • TÜV certified Software Winlog.validation • 6 x holding clamps for sensors • Aluminum carrying case...

Open the catalog to page 7
Data Logger Systems - 8

SL 3300 Complete validation set medical/dental For realization of different validations of various thermal processes in DAC UNIVERSAL, in small steam sterilizers according to ISO 17665 as well as washer disinfectors according to ISO 15883 Characteristics: • For steam sterilizers according to ISO 13060 (small sterilizer) • For washer disinfectors and endoscope washer disinfectors according to ISO 15883 • For DAC Universal according to ISO 13060 and ISO 15883 • Automatic calculation of the A0-values • Calculation of the F0 value • Calculation of the saturated steam temperature • Generation of...

Open the catalog to page 8
Data Logger Systems - 9

AL 3300 DAC adapter set for validation For the validation of thermal processes and cleaning process in DAC UNIVERSAL in accordance to ISO 17665 / ISO 15883 Characteristics: • Test according to ISO 15883 and ISO 13060 • All tests with original customer lid. A real validation with user parts • No heavy additional lids needed • Very reproducible, all sensors and instruments are always at the same position • Complete validation with thermal testing, test soil and real contaminated instruments possible • Data loggers of the SL 3300 are compatible The set contains: • 1 x Logger mount • 1 x PCD...

Open the catalog to page 9
Data Logger Systems - 10

Data logger and systems for spezial application Steam penetration test Certified by an independent laboratory according to ISO 11140-4. The EBI 16 Data logger together with the evaluation software Winlog.med is a very reliable and easy-to-use electronic measuring system. A comprehensive routine control of steam sterilizers can be performed by using electronic Bowie&Dick-Test according to ISO 17665 / EN 285. In addition to check steam penetration, also the relevant parameters of sterilization are controlled. A vacuum test can also be performed with this unit. The EBI 16 is designed so that a...

Open the catalog to page 10
Data Logger Systems - 11

H2O2 Sterilization (Plasma) EBI 10-TPX9X Very high precision pressure logger Very high precision pressure measurement starting at 0.1 mbar In the process of the H2O2 sterilizer, a very precise pressure measurement is necessary. The system is working at a pressure in the field of 1 mbar abs. Due to the very low working pressure close to the vacuum a special measuring system is required. For this range the EBI 10-TP X9X is designed. Type Ethylene oxide sterilization EBI 10-TH100-EX Temperature- /humidity data logger Resistant against EtO In the EtO sterilization cycle the performance depends...

Open the catalog to page 11

All Ebro Electronic catalogs and technical brochures