Routine Control WASHER-DISINFECTORS / STEAM -STERILIZERS
Open the catalog to page 1Routine checks for washer-disinfectors, steam-sterilizers and bed-pan washer-disinfectors made easy… SL 1610-Set Routine checks for washer-disinfectors, steam-sterilizers and bed-pan washer-disinfectors Washer-disinfectors, steam-sterilizers and bed-pan washer-disinfectors Set contains: 1 x EBI 15 BD-Test 1 x EBI 100-T100 Temperature Logger 1 x IF 150 Interface for EBI 15 and EBI 100 1 x Winlog.med Software 1 x AL 160 Carrying / Storage Case Description Type Part No. Starter Set SL 1610 1340-6572 BD-Test for steam-sterilizers and Temperature logger for routine checks in washer-disinfectors www.ebro.com...
Open the catalog to page 2Routine checks for washer-disinfectors and bed-pan washer-disinfectors Technical Data Type Temperature Data Logger -40 °C ... +150 °C (-40 °F ...+302 °F) 1 mbar ... 4,000 mbar (0.015 psi ... 58 psi) 0.3 °C (0.9 °F) from -40 °C ... +150 °C (-40 °F ... +302 °F) Pressure accuracy (EBI 100-TP231) Temperature resolution Pressure resolution (EBI 100-TP231) Memory Operating temperature Operating pressure Sensor Measurement mode EBI 100-T100 EBI 100-T100 Temperature measurement range Pressure measurement range (EBI 100-TP231) Temperature accuracy 20 mbar (0.3 psi) 0.1 °C (0.2 °F) 1 mbar (0.015 psi) 27,000...
Open the catalog to page 3www.ebro.com Peringerstraße ße 10 mbH • ic Gm D--8 ron ctro 505 E 5 Ele 5 In ngo bro 1e llst 1 01 ad t ©2 Electronic Bowie-Dick-Test Technical Data Type EBI 15 Temperature measurement range Pressure measurement range Accuracy Resolution Operating temperature Temperature sensor Channels Measurement mode 0 °C ... +150 °C (32 °F ... 302 °F) 1 mbar ... 4.000 mbar (0.015 ... 58 psi) ±0.1 °C (±0.2 °F) / ±15 mbar (±0.22 psi) 0.025 °C (0.045 °F) / 1 mbar (0.015 psi) 0 °C ... +150 °C (32° F ... 302 °F) Pt 1000 2 temperature, 1 pressure · endless mode · start / stop time · measurement upon start time ·...
Open the catalog to page 4Routine checks in the CSSD ebro Starter - Set SL 1010 for A -Value Calculation ® 0 For routine checks of washer-disinfectors and bed-pan washer-disinfectors Set contains: 1 x EBI 100-T100 Temperature data logger 1 x PHX 800 pH-Tester 1 x TDS 3 Conductivity tester 1 x EBI IF 100-1 Interface 1 x Winlog.med Software 1 x Carrying / Storage case ebro Starter - Set SL 1110 for A -Value Calculation and Pressure ® 0 Monitoring For routine checks of washer-disinfectors and steam-sterilizers Set contains: 1 x EBI 100-TP231 Temperature / Pressure data logger with Luerlock 1 x PHX 800 pH-Tester 1 x TDS 3...
Open the catalog to page 5ebro® Electronic GmbH Peringerstraße 10 • D-85055 Ingolstadt Tel. +49 (0) 841 - 9 54 78-0 Fax +49 (0) 841 - 9 54 78-80 Internet: www.ebro.com e-Mail: info @ ebro.com All names are registered tradenames or trademarks of ebro® Electronic GmbH -Specifications are subject to change without notice-
Open the catalog to page 68 Pages
132 Pages
176 Pages
18 Pages
36 Pages
28 Pages
4 Pages
6 Pages
4 Pages
12 Pages
180 Pages
156 Pages
156 Pages
6 Pages
4 Pages
6 Pages
16 Pages
20 Pages
4 Pages
6 Pages
12 Pages