The solution for increased patient safety
4Pages

{{requestButtons}}

Catalog excerpts

The solution for increased patient safety - 1

The solution for increased patient safety INDEPENDENT TESTING SYSTEMS FOR ENDOSCOPE WASHER-DISINFECTORS

Open the catalog to page 1
The solution for increased patient safety - 2

Finding a simple and reproducible means of testing correct endoscope washer-disinfector functionality has been a problem which has remained unsolved until now. The corporate developed Routine Control Set by ebro Electronic and spypach medical services now allows reproducible tests to be performed on the cleaning and disinfecting performance of various makes of device. The endoscope surrogate device is suitable both for single-channel inspections and for pressure chamber devices. This testing system is modelled on a thermo-labile flexible gastroscope or bronchoscope and is simply placed into...

Open the catalog to page 2
The solution for increased patient safety - 3

ebro Electronic and spypach medical services offers a flexible and reproducible test system for the validation of processes in endoscope washer-disinfectors according to ISO 15883. The pressure and temperature can be monitored with the data logger EBI 11 at exact defined positions inside the dummy. Commercial stainless steel test plates can be used for the validation of the cleaning performance. A test contamination according to EN ISO 15883 part 5 is also possible. Through the defined positions of the data loggers and the test plates is given highest reproducibility. Also, all endoscopes...

Open the catalog to page 3
The solution for increased patient safety - 4

Technical Data Measurement range: Temperature Accuracy Temperature Resolution Temperature Measurement range: Pressure Accuracy Pressure ± 15 mbar (0 mbar ... 4000 mbar) ± 20 mbar (4000 mbar ... 10000 mbar) Resolution Pressure Sensor: Temperature Piezo resistive, temperature compensated, internal, Luer-Look-connection Sensor: Presure Data memory Sampling rate Measurement mode Endless measurement Measurement start / stop time Measure upon start time Start immediately until end of memory Operating temperature Storage temperature Lithium, 2 x BR1225 A, 3V, user replacable 16.5 mm x 24 mm...

Open the catalog to page 4