This document provides an overview of professional measurement technology for monitoring temperature and humidity during the transport and storage of sensitive goods such as medicines and serums. It highlights various data loggers and thermometers designed for specific applications in the medical, pharmaceutical, and food industries.
Data Logger EBI 3x0
The EBI 3x0 series are user-friendly data loggers with USB connections for continuous monitoring of temperature and humidity. They are suitable for use throughout the cool chain process, in refrigerators, freezers, ambient conditions, and incubators. They can also measure very low temperatures with external probes.
Refrigerator Thermometer
This device is a min/max thermometer with external probes, used to monitor sample temperatures in laboratories and microbiological research facilities. It is essential for monitoring refrigerators storing pharmaceuticals, vaccines, chemicals, and blood bank supplies.
Data Loggers EBI 11 Series
The EBI 11 series are mini temperature and pressure data loggers used for validating DAC Universal, benchtop autoclaves, and washer disinfectors. They are crucial for process validation in steam sterilizers, autoclaves, and the production of canned goods.
EBI 12 Data Logger
This logger is used for routine control in steam sterilizers, autoclaves, washer disinfectors, and canning processes. It is also used for mapping and routine control in various sterilization processes.
SL 1111 Set
This set is designed for temperature and pressure monitoring, as well as A0 value calculation in washer disinfectors. It is part of ebro's specialized measurement systems for thermal processes in medical, pharmaceutical, and food industries.
EBI 12 Data Logger for Validation
The SL 3111 Set is used for the validation of steam sterilizers according to ISO 17665. It can be customized with data loggers, interfaces, and TÜV certified software for process validation in various sterilization processes.
Alternative Bowie & Dick-Test
The EBI 16, combined with Winlog.med software, provides a reliable electronic measurement system for routine control of steam sterilizers. It is designed for 1000 cycles or 3 years without calibration or service.
Training and Support
ebro offers training programs and workshops to meet the rising technical requirements. They provide on-site and worldwide training, supported by new training and meeting facilities established since 2016.
Contact Information
For further inquiries, ebro can be contacted via email or phone, with details provided in the document.
See more

Catalog excerpts

Validation, Routine Control and Process Monitoring-1

Validation, Routine Control and Process Monitoring PROFESSIONAL MEASUREMENT TECHNOLOGY

 Open the catalog to page 1
Validation, Routine Control and Process Monitoring-2

PDF Data Logger EBI 3x0 The easy to use data loggers with USB connection monitor the temperature and/or humidity. For continuous monitoring of temperature and/or humidity Measurement during the whole cool chain process Usage in refrigerators and freezers, in ambient conditions, incubators To measure very deep temperatures like liquid nitrogen with external probes Applications: monitoring the temperature and/or humidity during transport and storage of sensitive goods like medicine, serums

 Open the catalog to page 2
Validation, Routine Control and Process Monitoring-3

Refrigerator Thermometer Min/Max thermometer with external probes. To monitor the sample temperature in the laboratory And also in microbiological research facilities, a thermometer with minimum and maximum value display is required For monitoring all refrigerators for pharmaceuticals and vaccines, chemicals, blood banks and storage facilities Applications: for monitoring all refrigerators, pharmaceuticals and vaccines, chemicals, blood banks and storage facilit

 Open the catalog to page 3
Validation, Routine Control and Process Monitoring-4

Data Loggers EBI 11 Series Mini Temperature / Pressure For the Validation of DAC Universal, Benchtop Autoclaves as well as Washer Disinfectors. For the Validation of DAC Universal, benchtop autoclaves as well as washer disinfectors Process validation in steam sterilizers, autoclaves, in the production of canning, a.s.o. Process validation in washer disinfectors and washer disinfectors for endoscopes Process validation of Sirona DAC Universal MK III and MK IV Applications: Highly accurate temperature, pressure, humidity and conductivity data loggers for thermal validation proc

 Open the catalog to page 4
Validation, Routine Control and Process Monitoring-5

EBI 12 Data Logger for Routine control ebro® is specialist for measuring systems for flexible and reliable measureme thermal processes in the medical field, the pharmaceutical and the food indu Applications: • Routine control in steam sterilizers and autoclaves • Routine control in washer disinfectors and washer disinfectors for endoscopes • Routine control at canning • Mapping The SL 1111 Set for temperature and pressure monitoring as well as for Aq value calculation in washer disinfectors Applications: Routine control in steam sterilizers and autoclaves, in washer disinfectors and washer-disinfectors...

 Open the catalog to page 5
Validation, Routine Control and Process Monitoring-6

EBI 12 Data Logger for Validiation >nt and documentation systems for routine control and validation of various stry. Applications: • Process validation in steam sterilizers, autoclaves, in the production of canning, a.s.o. • Process validation in washer disinfectors and washer disinfectors for endoscopes • F0-value and A0-value calculation • Process validation in low temperature sterilizers such as EtO, LTSF and H2O2 The SL 3111 Set: for the validation of steam sterilizers according to ISO 17665. The set can be individually expanded or compiled by yourself from one or more data loggers (EBI 11...

 Open the catalog to page 6
Validation, Routine Control and Process Monitoring-7

Alternative Bowie & Dick-Test The EBI 16 forms together with the evaluation software Winlog.med an easy to use and reliable electronic measurement system. The EBI 16 is designed to ensure the use of 1000 cycles or 3 years without calibration or service For Routine control in steam sterilizers A vacuum test can also be car ried out with this device Applications: implementing a comprehensive routine control of steam sterilizers by means of the alternative Bowie&Dick-T

 Open the catalog to page 7
Validation, Routine Control and Process Monitoring-8

Training program. The technical requirements are rising steadily and thus the increased request for training and workshops. In the past, our customers have asked ebro® to provide training on-site and worldwide. By building the new training and meeting rooms, inclusive the associated laboratories, since 2016 we offer the optimum possibilities to perform seminars and workshops. You will find our current training program at www.ebro.com If you have questions regarding the registration we will support you: with email: [email protected] Xylem Analytics Germany Sales GmbH & Co. KG, ebro Peringerstr....