Overview
The LP980 Transient Absorption Spectrometer is a cutting-edge instrument designed for transient absorption research. It offers unparalleled measurement capabilities, including transient absorption, laser-induced fluorescence, and phosphorescence measurements up to 2.55 µm, with time ranges from nanoseconds to seconds. The dual monochromator/spectrograph allows for both spectral and kinetic acquisition.

Measurement Capabilities
  • Transient Absorption
  • Laser-Induced Fluorescence (LIF) and Phosphorescence
  • Time-Gated Spectra (ns, ms, ms time ranges)
  • Triplet-Triplet Annihilation
  • Reaction Rate Studies

Key Features
  • Dual sample chamber for transient absorption and laser-induced fluorescence
  • High sensitivity with detection limits of ΔOD 0.002 (kinetic) and ΔOD 0.0005 (spectral)
  • Two detectors: Spectral (ICCD) and/or time-resolved (PMT) data
  • Accurate kinetics over 9 orders of magnitude
  • L900 software for comprehensive control of all components and measurements

Specifications
Base Configuration
The LP980 uses the pump-probe technique for measuring transient kinetics and time-gated transient spectra. It includes a Czerny-Turner monochromator/spectrograph with a triple grating turret and a focal length of 325 mm. The laser excitation source is a single wavelength flashlamp pumped Q-switched Nd:Yag laser.

LP980-K (Kinetic Mode)
  • Grating: Plane ruled grating 1800 grooves/mm, 500 nm blaze
  • Dispersion: 1.66 nm/mm
  • Spectral Range: 200 nm – 870 nm
  • Spectral Resolution: 0.1 nm
  • Sensitivity: ΔOD 0.002 (fast detector), ΔOD 0.0005 (slow detector)
  • Detector Type: Photomultiplier with 5 stage dynode chain

LP980-KS (Kinetic & Spectral Mode)
  • Grating: Kinetic Mode grating plus an additional plane ruled grating
  • Dispersion: 19.9 nm/mm
  • Spectral Coverage: 520 nm
  • Spectral Resolution: 0.52 nm
  • Sensitivity: ΔOD 0.0005
  • Detectors: Kinetic Mode PMT plus an additional ICCD camera
  • Cooling: -20ºC standard, -30ºC with additional water circulation

Upgrade Options
  • Grating Options: Various gratings available from 150-2400 grooves/mm
  • Sample Holder Options: Cross-beam geometry, diffuse reflectance, thin-film, LIF
  • Detector Options: PMT-980, InGaAs Detectors, NIR-PMT
See more

Catalog excerpts

LP980 Data Sheet-1

Transient Absorption Spectrometer The LP980 spectrometer sets the standard for technical performance required in a transient absorption research instrument, offering unsurpassed measurement capabilities across a broad range of applications. A first of its kind in the market, the LP980 allows for the measurement of transient absorption and both laser-induced fluorescence and phosphorescence up to 2.55 µm, from nanoseconds to seconds. Spectral and kinetic acquisition are possible in the same instrument thanks to a dual monochromator/spectrograph. Key Features Dual sample chamber Measurement of transient absorption and laser-induced fluorescence Two detectors Spectral (ICCD) and/or time-resolved (PMT) data ns to seconds Accurate kinetics over 9 orders of magnitude High sensitivity Detection limit of ΔOD 0.002 (kinetic) and ΔOD 0.0005 (spectral) > Laser-Induced Fluorescence (LIF) and Phosphorescecene > Time-Gated Spectra (ns, ms, ms time ranges) > Triplet-Triplet Annihilation > Reaction Rate Studies L900 software One comprehensive package for control of all components and measuremen

 Open the catalog to page 1
LP980 Data Sheet-2

SPECIFICATIONS LP980 - Base Configuration The LP980 is a transient absorption spectrometer using the pump-probe technique for measuring transient kinetics (Kinetic Mode) and/or time-gated transient spectra (Spectral Mode), generated by laser excitation. Transverse sample excitation geometry comes as standard. Thin-film, diffuse reflection, fluorescence and phosphorescence lifetime measurement, accessories are available as options. MONOCHROMATOR / SPECTROGRAPH LASER EXCITATION SOURCE* Czerny-Turner with triple grating turret Focal length Automatic, computer-controlled for detector selection 5...

 Open the catalog to page 2

All Edinburgh Instruments catalogs and technical brochures

  1. EPLED SERIES

    2  Pages

  2. VPLED SERIES

    2  Pages

  3. VPL SERIES

    2  Pages

  4. HPL

    2  Pages

  5. EPL SERIES

    2  Pages

  6. IR5

    8  Pages

  7. DS5

    4  Pages

  8. RMS1000

    16  Pages

  9. RM5

    12  Pages

  10. FS5 Brochure

    9  Pages

  11. LP980 Brochure

    20  Pages

  12. MTL 5 Series

    2  Pages

  13. Mini T

    2  Pages

  14. Life Spec II

    4  Pages

Archived catalogs

  1. PL Series

    4  Pages

  2. FS5

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.