A70802985

A70802985
1 / 88 PagesView full catalog

A70802985

Product catalog summary
Introduction
The document provides comprehensive specifications and operational guidelines for Edwards' CDX1000 and IDX1000/IDX1300 dry vacuum pumps, including flameproof and safe area versions. It addresses ATEX compliance for systems requiring it and offers general information on pump motors, with specific details available in a separate manual.
Technical Data
The manual includes operating conditions, performance metrics, mechanical and electrical data, lubrication, and cooling requirements. It also details materials of construction and connection specifications.
Installation
Guidelines for safe unpacking, inspection, and pump location are outlined, along with instructions for connecting sensors, electrical supply, and cooling systems. Commissioning procedures and leak testing are also covered.
Operation
Operational safety measures and system control for both ATEX and non-ATEX systems are discussed. Procedures for starting, warming up, and shutting down the pump are provided.
Maintenance
The document outlines safety information and a maintenance plan, including checks for oil levels, coolant levels, and shaft-seals purge gas supply. Instructions for removing and replacing components like the inlet filter are included.
Compliance and Legislation
The product complies with EU directives on machinery safety, ATEX, RoHS, and REACH regulations. Material exemptions and hazardous substance declarations are specified, particularly concerning lead content.
Pump Components
Figures illustrate the components of the IDX and CDX pumps, including the pump motor, gearbox vent filter, heat exchanger, and other essential parts for operation and maintenance.
Specifications
Operating conditions include ambient temperatures from -20 to 40°C, with a maximum humidity of 90% RH and altitude of 1000 m. The pumps have a minimum pumping speed of 800 m3/h and a maximum outlet pressure of 1.15 bar. Lubrication and cooling systems are specified, with Mobil SHC 629 recommended for oil.
Operational Guidelines
CDX pumps are suitable for hazardous areas with specific certifications, while IDX pumps are for safe areas only. Prohibited uses include using the pump as a compressor or in explosive atmospheres.
Accessories and Maintenance
Various accessories are available for specific applications. Maintenance guidelines include using specific cleaning solutions and coolant types.
Safety and Compliance
The document emphasizes compliance with safety standards, including ATEX directives for hazardous environments, and provides warnings against misuse that could lead to safety hazards.
Specifications and Coolant Recommendations
Coolants must be amine-free, automotive-grade ethylene glycol antifreezes, diluted to 35%-50% with water. Edwards recommends using their own coolant for optimal corrosion protection.
Materials of Construction
Construction materials include SG iron for stators, rotors, and gear covers, steel for bearings and gears, and stainless steel for seals and flame arrestor elements.
Installation Procedures
Installation must be performed by trained technicians. Safety clothing is required when handling contaminated components. Proper leveling and securing with bolts are crucial to prevent distortion and overheating.
Leak Testing and Commissioning
Leak-test the system post-installation and seal any leaks. The pump's leak rate is tested to be less than 1 x 10-3 mbar l s-1. Commissioning involves isolating the pump, turning on cooling and purge systems, checking for leaks, and adjusting the TCV for temperature control.
Operational Safety
The CDX pump can handle flammable vapors and must be operated with a shaft-seals purge in ATEX systems. Maintain pump case temperature below specified limits to prevent automatic shutdown.
Maintenance Overview
Maintenance frequency should be adjusted based on process conditions. Clean processes may require less frequent maintenance, while harsh processes may necessitate more frequent checks.
Oil Level Checks
Regularly check the oil levels in the gearbox and end cover. If oil levels are frequently low or there is a sudden loss, it may indicate a fault, and the pump should be shut down for inspection.
Maintenance Schedule
A maintenance plan outlines tasks with recommended frequencies, such as weekly oil level checks, monthly inspections of bleed filters, and yearly cleaning of the cooling system.
Coolant Management
Instructions are provided for checking and refilling coolant levels, with warnings about pressure release and potential overheating.
Pipeline and Connection Inspections
Regular inspections of all pipelines and connections are necessary to ensure they are not corroded or damaged.
Oil and Filter Changes
Annual oil and filter changes are recommended, with detailed steps for draining and refilling oil, cleaning sight-glasses, and replacing filters.
Additional Maintenance Tasks
Other tasks include removing inlet filters after initial operation, inspecting process and exhaust pipelines, and replacing components like the pump motor and flexible coupling insert as needed.
Storage and Disposal
If storing the pump in temperatures below -14°C (7°F), drain oil and coolant. Ensure the pump is shut down, disconnect from electrical supply, and store in clean, dry conditions. Dispose of the pump and related materials safely, adhering to local and national safety and environmental regulations.
Service, Spares, and Accessories
Edwards products and services are available globally. Spare parts should be ordered with specific model and item numbers. A global network of service centers offers decontamination, repair, and rebuild services.
See more

Catalog excerpts

A70802985-1

Instruction Manual CDX1000 Chemical Dry Vacuum Pumps and IDX1000 and IDX1300 Industrial Dry Vacuum Pumps Item Number CDX1000, 30 kW, 50 Hz, Flameproof with Integral Flame Arrestors CDX1000, 40 h.p., 60 Hz, Flameproof with Integral Flame Arrestors CDX1000, 30 kW, 50 Hz, Flameproof (without Flame Arrestors) CDX1000, 40 h.p., 60 Hz, Flameproof (without Flame Arrestors) IDX1000, 30 kW, 50 Hz, Safe Area, Extended Performance IDX1000, 40 h.p., 60 Hz, Safe Area, Extended Performance IDX1300, 40 h.p., ANSI, Safe Area Notes: The Item Numbers listed above are for bareshaft pumps without motors. However, this manual contains general information on pump motors. For detailed information on the specific motor fitted to the pump, refer to the Motor Instruction Manual (P60074000) supplied with the pump. The CDX/IDX Pumping System Instruction Manual (P60074600) supplied with the system will define the build specification of the pump; that is, the type of motor and any accessories fitted. If the CDX pump is part of an ATEX system, an ATEX system instruction manual (P60074500) will be supplied, which defines the installation, operation and maintenance requirements for ATEX compliance. Original Instructions

 Open the catalog to page 1
A70802985-2

This page has been intentionally left blank.

 Open the catalog to page 2
A70802985-3

Edwards Ltd Innovation Drive Burgess Hill West Sussex RH15 9TW UK The following product(s): CDX1000, 30 kW, 50 Hz, Flameproof with Integral Flame Arrestors CDX1000, 40 h.p., 60 Hz, Flameproof with Integral Flame Arrestors CDX1000, 30 kW, 50 Hz, Flameproof (without Flame Arrestors) CDX1000, 40 h.p., 60 Hz, Flameproof (without Flame Arrestors) IDX1000, 22 kW, 50 Hz, Safe Area IDX1000, 30 h.p., 60 Hz, Safe Area IDX1000, 30 kW, 50 Hz, Safe Area, Extended Performance IDX1000, 40 h.p., 60 Hz, Safe Area, Extended Performance IDX1300, 30 kW, DIN, Safe Area IDX1300, 40 h.p., ANSI, Safe Area Note: The...

 Open the catalog to page 3
A70802985-4

Additional Legislation and Compliance Information EU RoHS Directive: Material Exemption Information This product is compliant with the following Annex III Exemptions: • 6(b) Lead as an alloying element in aluminium containing up to 0.4% by weight • 6(c) Copper alloy containing up to 4% lead by weight EU REACH Regulation Compliance This product is a complex article which is not designed for intentional substance release. To the best of our knowledge the materials used comply with the requirements of REACH. The product manual provides information and instruction to ensure the safe storage, use,...

 Open the catalog to page 4
A70802985-5

© Edwards Limited 2019. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 5
A70802985-6

© Edwards Limited 2019. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 6
A70802985-7

© Edwards Limited 2019. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 7
A70802985-8

Associated publications Publication title Publication number Vacuum pump and vacuum system safety Trademark credits Edwards and the Edwards logo are trademarks of Edwards Limited, Innovation Drive, Burgess Hill, West Sussex RH15 9TW. © Edwards Limited 2019. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 8
A70802985-9

This manual provides installation, operation and maintenance instructions for the Edwards CDX1000 chemical dry vacuum pumps and the IDX1000 and IDX1300 industrial dry vacuum pumps. The pump must be used as specified in this manual. Read this manual before installing and operating the pump. Important safety information is highlighted as WARNING and CAUTION instructions; these instructions must be obeyed. The use of WARNINGS and CAUTIONS is defined below. WARNING Warnings are given where failure to observe the instruction could result in injury or death to people. CAUTION Cautions are given where...

 Open the catalog to page 9
A70802985-10

The CDX and IDX pumps are rugged, reliable dry vacuum pumps designed specifically for use in the chemical and pharmaceutical industries, and in industrial processing applications. The CDX and IDX pumps are single stage pumps which use the screw principle, in which a pair of intermeshing, noncontacting rotors are held in correct phase relation by a pair of timing-gears. The gears and the double-row angular contact ball bearings are oil lubricated. The double-ended design means that the bearings, seals and gearbox remain at atmospheric pressure, and that axial loading on the bearings is minimal....

 Open the catalog to page 10
A70802985-11

Connect the shut-down thermal snap-switch to a suitable control circuit to shut down the pump if it overheats: refer to Section 3.7. Connect the two pressure switches to a suitable control circuit to shut the pump down if either of the oil circuits loses pressure. This is most easily done by wiring them in series. The shut-down thermal snap switch can be wired in series with the two pressure switches to shut down the pump if any one of the three switches trip. Connect the warning thermal snap-switch to the control equipment to provide an indication that the pump is too hot: refer to Section 3.7....

 Open the catalog to page 11
A70802985-12

Figure 1 - The IDX pump (Sheet 1 of 2) Pump motor (typical) Motor terminal box (typical) Gearbox vent filter Gearbox oil filler plug and bonded seal (in filler port) 5. Heat exchanger 6. Pump inlet 7. End cover vent filter 8. End cover oil filler plug and bonded seal (in filler port) 9. Thermal snap-switch box 10. End cover oil cooler 11. End cover oil level sight-glass (2 off*) 12. Mounting brackets (4 off) 13. Mounting pads (4 off, between items 12 and 14) 14. Mounting feet (4 off, box section) * 15. Cooling water outlet 16. Pump outlet 17. TCV (thermostatic control valve) 18. Gearbox oil level...

 Open the catalog to page 12
A70802985-13

Figure 1 - The IDX pump (Sheet 2 of 2) © Edwards Limited 2019. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.

 Open the catalog to page 13
A70802985-14

Figure 2 - The IDX1300 pump (Sheet 1 of 2) Pump motor (typical) Motor terminal box (typical) Gearbox vent filter Gearbox oil filler plug and bonded seal (in filler port) 5. Heat exchanger 6. Pump inlet 7. End cover vent filter 8. End cover oil filler plug and bonded seal (in filler port) 9. Thermal snap-switch box 10. End cover oil cooler 11. End cover oil level sight-glass (2 off*) 12. Mounting brackets (4 off) 13. Mounting pads (4 off, between items 12 and 14) 14. Mounting feet (4 off, box section) 15. Cooling water outlet * 16. Pump outlet 17. TCV (thermostatic control valve) 18. Gearbox oil...

 Open the catalog to page 14