1. Catalogs
  2. Edwards Lifesciences
  3. Edwards Protection Cannulae
video corpo

Edwards Protection Cannulae

Edwards Protection Cannulae
1 / 119 PagesView full catalog

Edwards Protection Cannulae

Product catalog summary
ThruPort Systems and Edwards Protection Cannulae Overview
ThruPort Systems
  • Disposables: ThruPort systems offer products for minimal incision valve surgery, enhancing visualization with a bloodless field. Key devices include the ProPlege cardioplegia device, EndoVent catheter, IntraClude occlusion device, and EndoClamp catheter.
  • Reusables: Long-shafted instruments and retractors are available for minimal incision valve surgery.
Edwards Protection Cannulae
  • Arterial Cannulae: Designed for oxygenated blood delivery during bypass surgery, including EndoReturn and EndoDirect cannulae for femoral and aortic cannulation.
  • Venous Cannulae: QuickDraw cannulae for draining non-oxygenated blood, featuring a thin wall design for excellent flow.
  • Accessory Devices: Includes disposable devices like the PeriVue retractor and knot pusher.
Key Features and Specifications
  • Devices support minimal incision approaches, providing clear fields and easy placement.
  • Pressure drop vs. flow rate data is provided for cannulae performance.
  • Devices are for professional use and require a physician's order.
Regulatory and Trademark Information
  • Devices meet Medical Device Directive 93/42/EEC requirements and bear the CE marking.
  • Trademarks include Edwards and product-specific names.
Ergonic Devices
  • Atrial Retractor: Improves mitral valve exposure with a tripod base, 360° movement, and articulating blades.
  • Rib Retractor System: Provides intercostal retraction with a low-profile design and multiple blade sizes.
  • Long Shafted Instruments: Includes forceps, scissors, and needle drivers with ergonomic handles.
EMBOL-X Glide Protection System
Minimizes trauma during surgeries with a low-trauma outflow path and advanced filter technology to capture emboli, reducing adverse events. Available in various kits and sizes.
EZ Glide Aortic Perfusion Cannula
Features a gentle, dispersive flow to protect against embolic dislodgement, with an auto-dilating tip for easy insertion.
Additional Cannula Types
Includes dispersion tip, metal tip, plastic tip, thin wall aortic, and axillary perfusion cannulae, each with specific features for surgical needs.
Pediatric Aortic Perfusion Cannula
Designed for pediatric surgery with various tip configurations.
Blood Management Products
Includes vent catheters, suction wands, pericardial sumps, visualization wands, intravascular shunts, and blood flow monitoring devices, all designed to support surgical techniques and maintain a well-vented site.
Regulatory Information
Devices are for professional use, restricted to sale by a physician's order, and meet Medical Device Directive 93/42/EEC requirements with CE marking.
See more

Catalog excerpts

Edwards Protection Cannulae-1

ThruPort Systems Edwards Protection Cannulae Product Guides

 Open the catalog to page 1
Edwards Protection Cannulae-3

For professional use. CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions, and adverse events. Edwards, Edwards Lifesciences, the stylized E logo, Edwards Protection Cannulae, and ThruPort are trademarks of Edwards Lifesciences Corporation. © 2011 Edwards Lifesciences Corporation. All rights reserved. AR07092, rev date 01/2012

 Open the catalog to page 3
Edwards Protection Cannulae-4

ThruPort Systems • Disposables • Reusables MIVS Redefined > THRUPORT SYSTEMS > TECHNOLOGY > TRAINING > SUPPORT AR07035, rev date 11/2011 ThruPort Systems ThruPort Systems

 Open the catalog to page 4
Edwards Protection Cannulae-5

1. Disposables Edwards Lifesciences’ ThruPort systems provide the broadest range of products for minimal incision valve surgery. Through peripheral cannulation, intra-aortic occlusion, and specialized techniques for myocardial protection, ThruPort systems offers excellent visualization of cardiac structures through a virtually bloodless, unobstructed operative field so surgeons can repair or replace the valve through the smallest incision possible*. *When compared to median sternotomy

 Open the catalog to page 5
Edwards Protection Cannulae-6

Retrograde Cardioplegia ThruPort systems ProPlege peripheral retrograde cardioplegia device is indicated for occlusion of the coronary sinus, delivery of cardioplegic solution and monitoring of coronary sinus pressure during cardiopulmonary bypass surgery. ProPlege Peripheral Retrograde Cardioplegia Device • ccludes coronary sinus, delivers retrograde crystalloid or blood cardioplegia into the O coronary sinus, and monitors coronary sinus pressure • cclusive balloon and large lumen allow delivery of cardioplegia at low pressures O • Articulating, steerable tip with ergonomic handle facilitates...

 Open the catalog to page 6
Edwards Protection Cannulae-7

Vent Catheter ThruPort systems EndoVent pulmonary catheter assists in decompressing the heart and maintaining a dry operative field via drainage from the pulmonary artery. EndoVent Pulmonary Catheter • ercutaneous insertion via internal jugular vein provides an unobstructed operative field P • hin wall, 8.3 Fr design delivers high flow rates to ensure adequate venting in all sizes of patients T • ontamination guard system facilitates sterile catheter repositioning C • re-shaped catheter and flow directed balloon enable easy placement into the pulmonary artery P 1 unit per case ________________________...

 Open the catalog to page 7
Edwards Protection Cannulae-8

Aortic Occlusion ThruPort systems provides two devices that work to occlude the ascending aorta, vent the aortic root, monitor aortic root pressure and deliver antegrade cardioplegia solution to arrest the heart. These products include the IntraClude intra-aortic occlusion device and the EndoClamp aortic catheter. IntraClude Intra-aortic Occlusion Device • 9 Fr, triple lumen catheter with an elastomeric balloon at its tip for occluding the A ascending aorta • he large central lumen of the catheter delivers antegrade cardioplegia and vents the aortic root T • Monitors aortic root and balloon pressures...

 Open the catalog to page 8
Edwards Protection Cannulae-9

Aortic Occlusion EndoClamp Aortic Catheter • 10.5 Fr wire-wound, triple lumen catheter with an elastomeric balloon at its tip for occluding A the ascending aorta • he large central lumen of the catheter delivers antegrade cardioplegia and vents the aortic root T • onitors aortic root and balloon pressures M • esigned for aortic approach and used with the EndoDirect arterial cannula (ED24A) D 1 unit per case ________________________ 25.5 inch (65 cm) overall length EC65 Vacuum relief valve 2 - 35 mL syringes Y-connector Red and blue pressure lines

 Open the catalog to page 9
Edwards Protection Cannulae-10

Arterial Cannulae ThruPort systems arterial cannulae are intended to deliver oxygenated blood for cardiopulmonary bypass surgery. Arterial: Pressure Drop vs. Flow* 120 EndoReturn Arterial Cannula • ire-wound, femoral arterial cannula W includes introducer, 0.038 inch guidewire (not shown), and connector hub • he “side-arm” and rotating hemostasis T valve allow for passage of the 100 cm IntraClude intra-aortic occlusion device (ICF100), providing for a single site for gentle occlusion of the ascending aorta, aortic root venting, delivery of antegrade cardioplegia and monitoring aortic root pressure...

 Open the catalog to page 10
Edwards Protection Cannulae-11

Arterial Cannulae EndoDirect Arterial Cannula Arterial: Pressure Drop vs. Flow* 250 • utoIncisor introducer facilitates easy, A single-step aortotomy • he “side arm” and rotating hemostasis T valve allow for passage of the 65 cm EndoClamp aortic catheter (EC65), providing for a single site for gentle occlusion of the ascending aorta, aortic root venting, delivery of antegrade cardioplegia and monitoring aortic root pressure Pressure Drop (mmHg) • nables 24 Fr direct aortic cannulation E and antegrade flow through a minimal incision approach Flow Rate (L/min) * ean value derived from in vitro...

 Open the catalog to page 11
Edwards Protection Cannulae-12

Arterial Cannulae Arterial Cannula Arterial: Pressure Drop vs. Flow* 100 • For femoral arterial cannulation • For use on small femoral arteries 1 unit per case Pressure Drop (mmHg) • Avoids high pressure Flow Rate (L/min) * ean value derived from in vitro testing performed with water at 21˚C. M The actual pressure gradients encountered in a clinical situation may 7 vary from those shown, depending on perfusion techniques. ________________________ 3.7 inch (9.4 cm) effective length AC19 19 Fr. (6.3 mm) 0.038 inch (100 cm) guidewire Introducer Connector hub

 Open the catalog to page 12
Edwards Protection Cannulae-13

Arterial Cannulae Introducer Sheath • or hemostatic introduction and removal of vascular catheters F • 9 Fr. cannula serves as separate introducer sheath for the IntraClude intra-aortic occlusion 1 device (ICF100) • otating hemostasis valve allows for passage of the 100 cm IntraClude intra-aortic occlusion R device (ICF100) • or use when bilateral cannulation is preferred F 1 unit per case ________________________ 3.7 inch (9.4 cm) effective length IS19A 19 Fr. (6.3 mm) 0.038 inch (100 cm) guidewire Introducer

 Open the catalog to page 13

All Edwards Lifesciences catalogs and technical brochures