Vascular Therapies
1 / 28Pages

Catalog excerpts

Vascular Therapies - 1

Vascular Therapies

Open the catalog to page 1
Vascular Therapies - 2

To navigate through this document simply click on any product or page number in this TOC. From any page you can return to this TOC by clicking on the TOC icon in the bottom right

Open the catalog to page 2
Vascular Therapies - 4

CLOT MANAGEMENT Fogarty® Arterial Embolectomy Catheters Preferred catheter for simple, rapid removal of soft, fresh emboli and thrombi from the arterial system • Hand tied using a recessed winding technique to secure balloon to catheter • Balloon exhibits a symmetry that exerts uniform contact with vessel walls for even pressure and precise traction • Soft, rounded tip promotes easy insertion for reduced trauma, arteriopuncture, and plaque avulsion Fogarty® arterial embolectomy catheters (tube pack) 1 unit per tube pack USABLE CATHETER LENGTH SIZE INFLATED MAX. SIZE MAX. MAX. MAX....

Open the catalog to page 4
Vascular Therapies - 5

CLOT MANAGEMENT Fogarty Fortis® Arterial Embolectomy Catheters Catheter of choice for more aggressive removal of emboli and thrombi from the arterial system • Construction and materials designed to be more durable and withstand greater pull-force • The addition of barium to the catheter shaft material provides radiopacity Fogarty® Fortis arterial embolectomy catheters 1 unit per tube pack COLOR MODEL USABLE CATHETER INFLATED MAX. SIZE MAX. MAX. MAX. COMPATIBLE REMOVABLE NUMBER LENGTH SIZE BALLOON OF DEFLATED GAS LIQUID RECOMMENDED INTRODUCER STYLET (CM) (F) DIAMETER BALLOON CAPACITY...

Open the catalog to page 5
Vascular Therapies - 6

CLOT MANAGEMENT Latex Free Embolectomy Catheters A latex free line of embolectomy catheters that feature: • Silicone balloon and catheter body • Stainless steel reinforced catheter body for strength, flexibility, and radiopacity • Smooth balloon attachment for ease of insertion Latex free embolectomy catheters (tube pack) COLOR MODEL NUMBER 1 unit per tube pack MAX. BALLOON INFLATION CAPACITY (ML) APPROXIMATE BALLOON DIAMETER (MM) Latex free embolectomy catheters (flat pack with syringe) COLOR MODEL NUMBER 1 unit per flat pack MAX. BALLOON INFLATION CAPACITY (ML) APPROXIMATE BALLOON...

Open the catalog to page 6
Vascular Therapies - 7

CLOT MANAGEMENT Over-the-wire Fogarty® Thru-Lumen Embolectomy Catheters Multi-use, guidewire-compatible design enables removal of soft, fresh emboli and thrombi as well as fluid delivery, temporary occlusion, and blood sampling • Tough, compliant Fogarty® balloon conforms to the vessel to maximize clot removal while minimizing trauma • Provides the solution for distal thrombus removal in the arterial system • Stainless steel bushings proximal/distal of the balloon • The addition of barium to the catheter shaft material provides radiopacity Fogarty® thru-lumen embolectomy catheters (flat...

Open the catalog to page 7
Vascular Therapies - 8

CLOT MANAGEMENT Fogarty® Adherent Clot Catheters Used to dislodge adherent thrombus in native vessels and synthetic grafts • Ideal for extracting the arterial plug and thrombus that is too resistant for an elastomeric balloon • Corkscrew design increases the surface area for entrapping fibrous material • Radiopaque and flexible for negotiating a forearm loop graft Fogarty® adherent clot catheters 1 unit per tube pack COLOR MODEL USABLE CATHETER MEMBRANE/SPIRAL MEMBRANE/SPIRAL DIAMETER NUMBER LENGTH SIZE DIAMETER MAX. EXTENDED MAX. RETRACTED Fogarty® Adherent Clot Catheter model 140806

Open the catalog to page 8
Vascular Therapies - 9

CLOT MANAGEMENT Fogarty® Graft Thrombectomy Catheters Used to dislodge adherent thrombus from synthetic grafts, such as aortofemoral polyester woven grafts • A less slow and cumbersome alternative to tools such as endarterectomy loops or spatulas Fogarty® graft thrombectomy catheters 1 unit per tube pack MEMBRANE/SPIRAL DIAMETER Fogarty® Graft Thrombectomy Catheter model 160245F

Open the catalog to page 9
Vascular Therapies - 10

CLOT MANAGEMENT Fogarty® Venous Thrombectomy Catheters Designed for removing thrombi in the venous system • The long, soft tip facilitates advancement past the venous valves without undue trauma Fogarty® venous thrombectomy catheters COLOR 1 unit per tube pack MODEL NUMBER INFLATED BALLOON DIAMETER (MM) MAX. SIZE OF DEFLATED BALLOON (F) Catheter Rack Catheter rack MODEL NUMBER Holds 50 Fogarty® catheters

Open the catalog to page 10
Vascular Therapies - 11

Atraumatic Occlusion

Open the catalog to page 11
Vascular Therapies - 12

ATRAUMATIC OCCLUSION Fogarty® Clamp Inserts • or the balance of atraumaticity and traction, F Fogarty® clamp inserts give you maximum flexibility - allowing you to choose the ideal type of occlusion to meet your surgical needs • ith several configurations and three different W sizes (33 mm, 61 mm, 86 mm), there’s a clamp insert for virtually every procedure you’ll perform Fogarty® clamp inserts Double Softjaw

Open the catalog to page 12
Vascular Therapies - 13

ATRAUMATIC OCCLUSION Fogarty Hydragrip® Clamps • even styles and configurations S of Fogarty Hydragrip surgical clamps are engineered to provide optimum performance when used with Fogarty® clamp inserts Fogarty Hydragrip® clamps MODEL CLINICAL APPLICATIONS Peripheral Vascular, Carotid Endarterectomy and Femoral Artery Procedures or Synthetic Grafts CV5025 Angled 11.8 33 Peripheral Vascular, Carotid Endarterectomy, Femoral, Iliac, Popliteal, Profunda and Renal Artery Procedures or Synthetic Grafts CV5030 Aortic and Vena Cava Occlusion or Gastro-Intestinal Procedures Aortic and Vena Cava...

Open the catalog to page 13
Vascular Therapies - 14

ATRAUMATIC OCCLUSION Cosgrove Flex Clamps • osgrove flex clamps from V. Mueller C instruments have flexible shafts that bend and contour 1 unit per box COMPATIBLE WITH FOGARTY® INSERT SIZE (MM) MODEL NUMBER QUICK BEND clamps 1 unit per box COMPATIBLE WITH FOGARTY® INSERT SIZE (MM) MODEL NUMBER

Open the catalog to page 14
Vascular Therapies - 15

ATRAUMATIC OCCLUSION Fogarty® Spring Clips and Handleless Clamps • For atraumatic occlusion of delicate blood vessels, Fogarty® spring clips and handleless clamps give you the versatility you • The variety of atraumatic jaw surfaces allows you to fine-tune your selection to address the needs of the procedure Fogarty® spring clips Fogarty Safejaw Spring Clip Fogarty Double Safejaw Spring Clip Fogarty EverClip Spring Clip Fogarty® handleless clamps 10 units per box COLOR MODEL DESCRIPTION JAW OPENING JAW Handleless Clamp Handleless Clamp 1 Tractionjaw

Open the catalog to page 15

All Edwards Lifesciences catalogs and technical brochures

  1. EVOQUE

    7 Pages

  2. PASCAL

    4 Pages

  3. OptiSite

    2 Pages

  4. PediaSat

    4 Pages

  5. Flo Trac

    4 Pages