Quality made in TURKEY EFLAB BIOSAFETY CABINET CLASS 2 A EFLAB Class II Type A Biological Safety Cabinets works under principles of air circulation and air filtration by keeping the working area under negative air pressure. In BSC, 70% (+/-%5) of total air is recirculated and filtered through the main HEPA filter located at work zone top. The rest of the air, 30% (+/-%5), is exhausted to the surrounding area environmentally protected after passing through the exhaust HEPA filter. The room air is pulled through the perforations located in front of the work plate and directed to blower plenum (inflow air). This airflow direction prevents dirty air reaching to the materials over the working plate. Inflow air together with recirculated air is mixed at the blower plenum then passes through the main HEPA filter and laminarizator and reaches into the work area protecting the work zone, under ISO-5 class laminar airflow. In addition to the primary air barrier accomplished by the negative pressure within the working zone double-wall negative plenum design of the EFLAB cabinet prevents particle from escaping to surroundings and zero leakage is ensured.Antibacterial Epoxy Powder paint Coated Stainless Steel < 70 angles sloped front panel for work comfort and increased work-chamber vision Easy reachable electronic control & electrical part protection inside at front panel isolated from work-chamber UV Resistant tempered glass Aerosol-tight sash window One key touch on-off Timer setting Inflow/Downflow Air Velocity/Airflow Rate System Ready/Not-Ready message/warning Normal/Stand-by option button Automated airflow rate and velocity compensation system HEPA Filter Life (percent) Total Work-Time UV and FL Lamp Work-times Automatic Stand-by status at sash window closure Motorized sash window level position setting One key sash window Preset position Automatic UV Lamp-Off protection at the sash window opening Sash window position message Servicing records Pas
Open the catalog to page 1Quality made in TURKEY EFLAB TECHNICAL TABLE Internal Dimensions (WxLxH) mm External Dimensions (WxLxH) mm Support Stand (WxLxH) mm Support Stand Height From Ground Inflow Air Flow (m/s) Downflow Main Filter HEPA Filter Types (EN 1822) Exhaust Filter Pre-Filter (EN779, Opsiyonel) Working Table (Single piece monoblock or multiple pieces withhold apparatus) < ISO 5 < Class 100 304 Stainless Steel Clean Area Class Preset/Std Max Normal Mode Eco (Stand by) Mode Front Glass Aperture (mm) Noise Level Working Area Illumination (Lux) Front Glass Fan Filter Unit Illumination UV Lamp Electrical socket...
Open the catalog to page 2