Group: EIZO Inc.
Catalog excerpts
Diagnost ic Monitors All product names are trademarks or registered trademarks of their respective companies. EIZO, RadiForce, FlexScan, ScreenManager, RadiCS and RadiNET are registered trademarks of Eizo Nanao Corporation. Specifications are subject to change without notice. www.eizo.com Copyright © 2012 EIZO NANAO CORPORATION. All rights reserved. Printed in Japan,10, 2012, 4K (121001)
Open the catalog to page 1The EIZO Brand Since our beginnings as an OEM manufacturer of black and white televisions in 1968, EIZO has been researching and developing visual display products. In 1981, we released our first CRT monitor for personal computers. And in 1985, we launched products for the European and American markets under the universal brand name “EIZO”. To Markets Across the World Today, EIZO monitors are highly regarded in various fields throughout the world because of their accurate and stable image display and innovative features. EIZO is based in Japan and represented in over sixty countries by a...
Open the catalog to page 2-optimal monitor edical imaging Optimum monitor Monitors have grayscale tone characteristics which may vary eve between the same models. Therefore, when medical images ar displayed on standard monitors, they may not offer unified displa between multiple monitors. Monitor quality, which is determined by brightness, grayscale and brightness uniformity characteristics, change slowly over time. It is important that you select monitors which are calibration compliant with the DICOM Part 14 to ensure continuing monitor quality control. Information volume of a medical image differs depending on...
Open the catalog to page 3RadiForce* G&R-Series Diagnostic Monitors RadiForce G&R-Series specially designed 1, 2, 3, 4, 5, 8 and 10 megapixel monochrome and color monitors take full account of medical institutions' need for different types of monitors with DICOM Part 14 standard calibration and high-performance capabilities required for confident diagnosis. Diagnostic Precision with DICOM Part 14 Factory Adjustment To ensure the most accurate and consistent shadings possible, EIZO care- fully measures and sets every grayscale tones on the production line to produce a monitor compliant with DICOM Part 14. Consistency...
Open the catalog to page 4Common Features Mode Selection for Optimum Viewing Selectable with the front panel buttons, the CAL Switch function allows for various modes of different modalities such as CR, CT, and endo- scope images. Number or type of the modes vary by model. Grayscale : DICOM Parti 4 Presence Sensor for Power Savings The presence sensor feature unites convenience with savings by ensuring that the monitor conserves power when it is not in use. The presence sensor prompts the monitor to switch to power save mode when it detects the user is away from the monitor, and then resume normal operation when the...
Open the catalog to page 510 & 5 Megapixel Diagnostic Monitors With its widescreen format, the RadiForce GX1030 is an optimal replacement for dual head 5 megapixel display installations. Featuring high definition, high resolution and multi-grayscale, the RadiForce GX540 and GX530 are designed specifically for displaying digital mammography images. 54 cm (21.3") LCD Monitor 54 cm (21.3") LCD Monitor 76 cm ( 30") LCD Monitor High-Resolution Thanks to its unique Mono-Pixel design and a pixel pitch size of just 0.158 mm, the RadiForce GX1030 offers exceptionally high brightness 0.165 mm 0.158 mm levels and a wide...
Open the catalog to page 68 & 4 Megapixel Diagnostic Monitors The RadiForce RX840 is a new 8 megapixel super high resolution diagnostic color monitor for versatile medical imaging. The high resolution of 4 megapixels gives RadiForce RX440 and RX430 the same amount of screen size and number of pixels as two 2 megapixel monitors in portrait mode but without the obtrusive bezels. 92 cm (36.4") LCD Monitor 76 cm (29.8") LCD Monitor 76 cm (29.8") LCD Monitor 8 Megapixel Super-High-Resolution Display Environmentally-Friendly LED Backlight By utilizing an energy-efficient LED as a backlight, the monitor achieves a...
Open the catalog to page 73,2 &1 Megapixel Diagnostic Monitors By utilizing an energy-efficient LED as a backlight, the monitor achieves a high-brightness and low power consumption at the same time. Unlike conventional CCFL backlights, LED backlights deterio- rate more slowly and thus the monitor offers a longer service life. Since the LED backlight is mercury free, it will reduce any potential impact on the environment when it is disposed of. LED meets EIZO medical monitors fgjB| Color and Monochrome Images with Separate Gamma Curves EIZO' s unique Hybrid Gamma function distinguishes whether the images being...
Open the catalog to page 8Graphics Board Compatibility ElZO-recommended graphics boards come with drivers that have validated for use with RadiForce monitors. This contributes to smooth installation of monitors into the hospital systems where high reliability ami stable operation are required. Graphics board compatibility is subject to change without notice. Please check the website for updates.
Open the catalog to page 9Monitor Quality Control Solutions With filmless imaging spreading in the medical world, there is a growing interest in maintaining the quality of monitors displaying medical images. With the know-how and experience as a specialist in monitor manufacturing, we offer state-of-the-art solutions for the quality control of monitors which will lead to the improvement of the quality of medical care itself. I Quality Control Software I User-Friendly Interface and Enhanced Operability I Acceptance and Constancy Testing in Easy Steps I Flexible Schedule Setting I DICOM Part 14 Calibration I Network...
Open the catalog to page 10Model Variations RX430: With Stand, Without Panel RX430-FC: Without Stand, With Panel Grayscale Tones / Display Colors 10-bit colors (DisplayPort) : 1.07 billion (maximum) colors 8-bit colors: 16.77 million from a palette of 8-bit: 256 from a palette of 16,369 tones 10-bit (DisplayPort): 1,024 from a palette 8-bit: 256 from a palette of 16,369 tones 10-bit colors (DisplayPort) : 1.07 billion (maximum) colors 8-bit colors: 16.77 million from a palette of 10-bit colors (DisplayPort) : 1.07 billion (maximum) colors 8-bit colors: 16.77 million from a palette of 10-bit (DisplayPort): 1,024 from...
Open the catalog to page 11All EIZO Corporation catalogs and technical brochures
-
CuratOR® LX3240-MR
2 Pages
-
CuratOR® LX1910
2 Pages
-
CuratOR® SP1-24
2 Pages
-
TID0102
2 Pages
-
PDC0100
2 Pages
-
CuratOR EX2621
2 Pages
-
SP2-24-49
2 Pages
-
SP2-24
2 Pages
-
TIP0210-DVI
2 Pages
-
EX3241
2 Pages
-
EX5841
2 Pages
-
MX194
2 Pages
-
SCD 19102
2 Pages
-
Radiforce RX1270
3 Pages
-
CuratOR Caliop
2 Pages
-
CuratOR SC430-PTR
3 Pages
-
RadiForce general
15 Pages
-
Raptor SQ2801
2 Pages
-
EX3220
2 Pages
-
EX2620-3D
2 Pages
-
EX3220-3D
2 Pages
-
EX3141-3D
2 Pages
-
EX3140
2 Pages
-
RadiForce MX315W
2 Pages
-
RadiForceGX550
2 Pages
-
RadiForce LX600W
2 Pages
-
RadiForce LX300W
2 Pages
-
RadiForce GS521
5 Pages
-
RadiForce EX270W
2 Pages
-
FORIS FS2333
5 Pages
-
FORIS FS2332
4 Pages
-
FORIS FS2331
4 Pages
-
ColorEdge CG247 CX241
13 Pages
-
FORIS FG2421
3 Pages
-
ColorEdge CE210W, CE240W
4 Pages
-
ColorEdge Graphics
8 Pages
-
FlexScan M1950, L578
4 Pages
-
FlexScan L778, L578
4 Pages
-
CuratOR Products
13 Pages
-
TDL 3600 / TDL 2300
2 Pages
-
EX190
2 Pages
-
RadiForce MX215
2 Pages
-
MX242W
2 Pages
-
SMD 19102
2 Pages
-
SMD 19102
2 Pages
-
RadiForce RX650
2 Pages
-
FlexScan L885
2 Pages
-
FlexScan L985EX
2 Pages
-
FlexScan S2100
2 Pages
-
FlexScan L997
2 Pages
-
FlexScan S2242W
2 Pages
-
FlexScan EV2333W, EV2313W
4 Pages
-
FlexScan EV2335W, EV2315W
4 Pages
-
FlexScan EV2303W, EV2023W
4 Pages
-
FlexScan HD2441W
6 Pages
-
FlexScan EV2411W
4 Pages
-
FlexScan S2111W, S2411W
4 Pages
-
FlexScan General 2013,10
9 Pages
-
FlexScan HD2442W
6 Pages
-
FlexScan S2410W, S2110W
4 Pages
-
FlexScan S2432W, S2232W
4 Pages
-
FlexScan SX3031W
2 Pages
-
RadiForceMS231WT
2 Pages
-
RadiForceMS230W
2 Pages
-
RadiForceMX270W
2 Pages
-
RadiForce_MX-Series
7 Pages
-
RadiForceRS110
2 Pages
-
_RadiForceRS210.
2 Pages
-
_RadiForceRX240.
2 Pages
-
RadiForceRX320
2 Pages
-
RadiForce RX340
2 Pages
-
RadiForce_RX440.
2 Pages
-
RadiForce RX840-MG
2 Pages
-
RadiForce L&E-Series
13 Pages
-
RadiForce GS220
2 Pages
-
RadiForce GX240
2 Pages
-
RadiForce GS320
2 Pages
-
RadiForce GX340
2 Pages
-
RadiForce GX540
2 Pages
-
RadiForce GX1030
2 Pages
-
RadiForce Mammo-Series
7 Pages