1. Catalogs
  2. Elabscience Biotechnology Inc.
  3. Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit

Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit
1 /13Pages

Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit

Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit
1 /13Pages

Catalog excerpts

Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-1

(FOR RESEARCH USE ONLY. DO NOT USE IT IN CLINICAL DIAGNOSTICS ! ) Catalog No: E-OSEL-H0001 Product size: 96T/48T/24T/96T*5 This manual must be read attentively and completely before using this product. If you have any problems, please contact our Technical Service Center for help (info in the header of each page). Email: [email protected] Website: www.elabscience.com Please refer to specific expiry date from label outside of box. Please kindly provide us with the lot number (on the outside of the box) of the kit for more efficient service.

 Open the catalog to page 1
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-2

QuicKey Pro Series Get more sensitive and precise results with saving at least 1-2h comparing to traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way. Intended use This ELISA kit applies to the in vitro quantitative determination of IL-6 concentrations in Human serum and plasma samples. Please contact tech-support for other sample type detection. Test principle This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human IL-6. Samples...

 Open the catalog to page 2
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-3

Kit components & Storage An unopened kit can be stored at 2-8 °C for 6 months. After test, the unused wells and reagents should be stored according to the table. Note: All reagent bottle caps must be tightened to prevent evaporation and microbial pollution. The volume of reagents in partial shipments is a little more than the volume marked on the label, please use accurate measuring equipment instead of directly pouring into the vial(s).

 Open the catalog to page 3
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-4

Other supplies required Microplate reader with 450 nm wavelength filter High-precision transfer pipette, EP tubes and disposable pipette tips Incubator capable of maintaining 37℃ Deionized or distilled water Absorbent paper Loading slot Sample collection (More detailed information please view our website: https://www.elabscience.com/Listdetail-259.html) Serum: Allow samples to clot for 1 hour at room temperature or overnight at 4℃ before centrifugation for 20 min at 1000×g at 2-8℃. Collect the supernatant to carry out the assay. Blood collection tubes should be disposable and be non-endotoxin....

 Open the catalog to page 4
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-5

Note  Note for kit 1) For research use only. Not for use in diagnostic procedures. 2) Please wear lab coats, eye protection and latex gloves for protection. Please perform the experiment following the national security protocols of biological laboratories, especially when detecting blood samples or other bodily fluids. 3) A freshly opened ELISA plate may appear a water-like substance, which is normal and will not have any impact on the experimental results. Return the unused wells to the foil pouch and store according to the conditions suggested in the above table. 4) Do not reuse the reconstituted...

 Open the catalog to page 5
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-6

Dilution Method It is recommended to do the experiment with undiluted Human serum and plasma samples. Due to individual differences, please estimate the concentration range of the sample in a dvance, and conduct a preliminary test to determine the appropriate dilution ratio of the sample. If your test sample needs dilution, please refer to the dilution method as follows: For 100 fold dilution: One-step dilution. Add 5 μL sample to 495 μL sample diluent to yield 100 fold dilution. For 1000 fold dilution: Two-step dilution. Add 5 μL sample to 95 μL sample diluent to yield 20 fold dilution, then...

 Open the catalog to page 6
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-7

and mix up to produce a 100 pg/mL working solution. Pipette 500 pL of the solution from the former tube into the latter one according to this step. The illustration on the next page is for reference. Note: the last tube is regarded as a blank. Don’t pipette solution into it from the former tube. Gradient diluted standard working solution should be prepared just before use. 4. HRP Conjugate working solution: HRP Conjugate is HRP conjugated antibody. Calculate the required amount before the experiment (50 pL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the...

 Open the catalog to page 7
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-8

Assay procedure 1. Determine wells for diluted standard, blank and sample. Add 50 μL each dilution of standard, blank and sample into the appropriate wells (It is recommended that all samples and standards be assayed in duplicate. It is recommended to determine the dilution ratio of samples through preliminary experiments or technical support recommendations). Immediately add 50 μL of HRP Conjugate working solution to each well. Cover the plate with a new sealer. Incubate for 60 min at 37° Note: C. solutions should be added to the bottom of the micro ELISA plate well, avoid touching the inside...

 Open the catalog to page 8
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-9

Assay Procedure Summary

 Open the catalog to page 9
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-10

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only. The above samples were from normal healthy individuals during non-menstrual period or pregnancy.

 Open the catalog to page 10
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-11

■ Precision Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human IL-6 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human IL-6 were tested on 3 different plates, 20 replicates in each plate, respectively.

 Open the catalog to page 11
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-12

Troubleshooting If the results are not good enough, please take pictures and save the experimental data in time. Keep the used plate and remaining reagents. Then contact our technical support to solve the problem. Meanwhile, you could also refer to the following materials:

 Open the catalog to page 12
Elabscience® QuicKey Pro Human IL-6(Interleukin 6) ELISA Kit-13

Declaration 1. Limited by current conditions and scientific technology, we can't conduct comprehensive identification and analysis on all the raw material provided. So there might be some qualitative and technical risks for users using the kit. 2. This assay is designed to eliminate interference by factors present in biological samples. Until all factors have been tested in the ELISA immunoassay, the possibility of interference cannot be excluded. 3. The final experimental results will be closely related to the validity of products, operational skills of the operators, the experimental environments...

 Open the catalog to page 13

All Elabscience Biotechnology Inc. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.