Integrity 10 Reaction Station
12Pages

{{requestButtons}}

Catalog excerpts

Integrity 10 Reaction Station - 1

Wide range of accessories Highly accurate and controllable Environmentally conscious Suitable for many disciplines Energy efficient Various diameter vessels Sample capacity choice STEM Integrity 10 Reaction Station

Open the catalog to page 1
Integrity 10 Reaction Station - 2

Introducing the Integrity 10 STEM Integrity 10 Reaction Station The STEM Integrity 10 Reaction Station’s evolutionary design provides the advanced laboratory with a means for allowing the users to perform multiple reactions at individually set temperatures both in negative and positive temperature ranges simultaneously. Each cell position can be heated/ cooled and stirred independently of the cell next to or adjacent to it. The versatility of the product means it can be used inside a fume cupboard, mounted onto a robotic platform, coupled together as multiple units for mass sampling or...

Open the catalog to page 2
Integrity 10 Reaction Station - 3

Integrated microprocessor control with exclusive user-friendly and intuitive touchscreen The integrated microprocessor control with exclusive touchscreen simplifies operation and enables rapid access to important information for each critical parameter in the reaction block. It provides trend analysis for convenient evaluation of your station's performance without connecting a laptop. Key features 1. Simple and intuitive touch screen interface allows quick and easy navigation. 2. Profile template enables the quick set up and execution of temperature and stirring profiles. 3. Graphical...

Open the catalog to page 3
Integrity 10 Reaction Station - 4

Choice of formats The STEM Integrity 10 is most commonly utilised in two formats depending upon your needs: • Option 1: STEM Integrity 10 Reaction Station as a standalone unit. • Option 2: Clarity System, which consists of the STEM Integrity Reaction Station, with additional solubility and crystallisation evaluation apparatus and software. The STEM Integrity 10 unit Option 1, the STEM Integrity 10 unit by itself, is generally useful for a wide range of reactions or processes in which temperature plays a major role, regardless of the industry. Within a temperature band of -30°C to 150°C, it...

Open the catalog to page 4
Integrity 10 Reaction Station - 5

Macro Process Control with User-friendly Touchscreen and Integrated Microprocessor The Integrity 10 captivates by its simple operation and the clear representation of all process-relevant parameters and results. Each reaction cell is individually controlled and evaluated. The Integrity 10 is easy to set-up using the touch screen. With an intuitive menu system, operation is both quick and simple allowing the user to set-up and operate a simple profile or operate with full manual control. Simplicity itself: Five Step touchscreen operation 1. Cell/position selection Just select one of the 10...

Open the catalog to page 5
Integrity 10 Reaction Station - 6

A highly efficient screening tool… Using the STEM Integrity 10 Reaction Station is a very time-efficient way of conducting chemical experiments, speeding up investigative work several-fold. Chemical reactions, involving either synthetic chemicals or naturally occurring substances, are universally impacted by heat and Integrity units allow you to assess the impact of both temperature and stirring rate upon reactions. The beauty of the STEM Integrity 10 is that it combines flexibility with accuracy: It allows you to run up to 10 experimental variants simultaneously within the same unit, whose...

Open the catalog to page 6
Integrity 10 Reaction Station - 7

Solubility Crystalization Software The accessory PC-software has all functions of the on-board software of the Integrity 10 and beyond that it enables an even more global handling of the data. The process data of the conditions in the individual cells e.g. temperature and stir speed, are clearly displayed. The extremely user friendly software enables the real-time editing of ramps, process times and set values. In addition the software allows easy control of the optional IR probes. The software enables graphical on-screen monitoring of solubility/crystallisation and automatically plots the...

Open the catalog to page 7
Integrity 10 Reaction Station - 8

The Clarity System For the Solubility/Crystallisation Studies Crystallisation processes are used in the manufacture of speciality chemicals, fine chemicals and pharmaceuticals. The first step in the crystallisation process is determining the solubility compound in a selection of aqueous, organic solvents and/or solvent mixtures. Solubility determines methods for supersaturation and the yield in the crystallisation process. Unfortunately, determining the solubility of a compound can be labour intensive and consume large quantities of material/chemical solution. The Clarity Solubility Station...

Open the catalog to page 8
Integrity 10 Reaction Station - 9

Super energy-efficient alternatives to hotplate stirrers Supporting modern ways of working Although Integrity 10 Reaction Stations can perform highly accurate specialised work, their value-added credentials make them a credible alternative to hotplate stirrers. The first hotplate was patented in 1859 by George Simpson, and despite improvements such as the incorporation of magnetic stirring, the design of hotplate stirrers still wastes a lot of energy in heating the surrounding air, equating to wasted money and unnecessary CO2 emissions. In contrast, almost all the energy generated by...

Open the catalog to page 9
Integrity 10 Reaction Station - 10

Number of cell positions Cell cavity diameter Glass vessel fill level Temperature range Temperature difference between any two positions Temperature overshoot (maximum) Maximum heating/cooling rate Temperature ramp rate Stir speed range Maximum viscosity capacity Recommended stir bars Temperature Range Temperature Resolution Temperature Accuracy Stirrer Speed range Stirrer Resolution Stirrer Accuracy 350 to 1200 rpm Glycerine at 25°C 12/4.5mm (cylindrical) or 10/6mm (oval) • Minimum temperature is linearly dependent upon the temperature of the cooling fluid. Specified range assumes a...

Open the catalog to page 10
Integrity 10 Reaction Station - 11

Integrity 10 with 10 individually controlled cells, UK , US & EU power leads Integrity 10 reflux/inerting unit SVL 22 thread inerting caps for use with ATS20100 Glass tubes 24 / 150mm, SVL 22 thread pack of 10 Kimble thread inerting caps for use with ATS20100 Kimble thread 24 / 150mm glass tubes compatible with ATS20003 Small volume test tubes 24 - 16mm taper ( 3ml ) x10 Reducing sleeves for ATS10055 x10 Small volume test tubes 24 - 11mm taper ( 1ml ) x10 Reducing sleeves for ATS10209 Stirrer bars 10 / 6mm, pack of 10 Stirrer bars 12 / 4.5mm, pack of 10 Multi-Temp 10 plug-in box Temperature...

Open the catalog to page 11

All Electrothermal catalogs and technical brochures

  1. Lab Essentials

    100 Pages

  2. Digi-Mantles

    3 Pages

  3. Controllers

    6 Pages

Archived catalogs

  1. TechneWorks

    1 Pages

  2. Tecal 425F

    1 Pages

  3. Tecal 425S/H

    1 Pages

  4. Tecal 650F

    1 Pages

  5. Tecal 650S/H

    1 Pages

  6. Stirrers

    7 Pages