video corpo

enviro TOC

enviro TOC

enviro TOC

Product catalog summary
Introduction
The document introduces the enviro TOC, a Total Organic Carbon analyzer designed for environmental and wastewater laboratories. It highlights the analyzer's high data quality, flexibility, durability, and ease of use.

Features
The enviro TOC features a fully automated 60-position sampler for 40 ml EPA vials, matrix separation with SALTTRAP for low maintenance, combustion temperatures up to 1200 °C, and integrated chemiluminescence detection for TNb. It also includes rinsing functions to minimize carryover and increase the injection unit's lifetime.

Technological Innovations
The enviro TOC combines proven functions with new technologies, including a powerful furnace, variable mode changes, real matrix separation with SALTTRAP, and a novel autosampler system. It is designed for flexible and efficient TOC and TNb determination in environmental and wastewater samples.

Applications
The analyzer is tailored for TOC, NPOC, TC, TIC, DOC, POC, or TNb analysis in various matrices, including surface water, wastewater, groundwater, waste, and soil. It offers fully automatic TOC determination in both solid and liquid samples.

SALTTRAP Technology
The unique SALTTRAP technology ensures user-friendly maintenance intervals for the combustion tube and catalyst, even for concentrated salt solutions, reducing running costs.

Nitrogen Determination
The enviro TOC enables simultaneous TNb determination using EC cell technology or a novel chemiluminescence detector (CLD), providing stable conditions for NO measurement and simplifying calibration and result evaluation.

High-Temperature Combustion
The analyzer complies with international standards, oxidizing TOC at temperatures > 680 °C, with the capability to reach up to 1200 °C for optimal oxidation of stable compounds.

TOC Measurement Principle
The TOC measurement is based on catalytic high-temperature combustion, oxidizing carbon to CO2, which is quantitatively determined with an IR detector. The process is automated, avoiding hazardous substances and providing quick analysis.

Compliance and Standards
The enviro TOC complies with standards such as ISO 20236, ISO 8245, EN 1484, EN 12260, SM 5310B, EPA 415.1, and ASTM D7573 for liquid samples, and EN 15936 and ISO 10694 for solids.

Maintenance and Longevity
The analyzer is designed for easy and cost-effective maintenance, with user-replaceable consumables and accessible components, ensuring minimal downtime and reduced running costs.

Software Integration
The lyticOS software optimizes system performance and reliability, reducing operator demand and enhancing system efficiency.

Conclusion
The enviro TOC is presented as an ideal solution for environmental laboratories, research institutes, and quality control, offering precision, accuracy, and compliance with official standards.
See more

Catalog excerpts

enviro TOC-1

enviro TOC TOC analysis of environmental water and wastewater at its best High data quality Great flexibility Extreme durability

 Open the catalog to page 1
enviro TOC-2

Convenient handling, smooth & precise analyses • Matrix separation with SALTTRAP • Fully automated, 60-position sampler for 40 ml EPA vials guarantees low maintenance for salt-containing samples • Combustion temperatures up to 1200 °C crack even stable carbon compounds • Fast conversion from liquids to solids mode ensures high flexibility • Integrated chemiluminescence detection with a large linear measurement range for TNb • Rinsing functions minimize carryover and increase the lifetime of the injection unit TOC analyzers from Elementar based on catalytic high-temperature combustion have been...

 Open the catalog to page 2
enviro TOC-3

Designed for environmental samples TOTAL ORGANIC CARBON (TOC) The analysis of TOC in wastewater to assess organic contamination or to evaluate the cleaning efficiency of sewage treatment The TOC measuring principle of the enviro TOC is plants is an international standard procedure. Also, TOC and TNb based on catalytic high-temperature combustion determination are indispensable for monitoring organic pollution of the sample in an oxygen stream > 680 °C. and nitrogen load in surface waters. Under these conditions, all bound and dissolved The enviro TOC is tailored to the analysis of TOC, NPOC,...

 Open the catalog to page 3
enviro TOC-4

TOC / TNb analysis has never been easier! IN ACCORDANCE WITH OFFICIAL STANDARDS The enviro TOC works in compliance with all relevant standards for TOC, TC, TIC and TNb in liquid samples such as ISO 20236, ISO 8245, EN 1484, EN 12260, SM 5310B, EPA 415.1, and ASTM D7573. Due to the unique solids option, TOC and TC can also be determined in solids like soil or waste according to EN 15936 and ISO 10694. EASY AND COST-EFFECTIVE MAINTENANCE The user-friendly maintenance concept of the enviro TOC ensures the most efficient routine analysis: Our SAVE TIME WITH lyticOS® SOFTWARE goal is that the maximum...

 Open the catalog to page 4

All Elementar catalogs and technical brochures

  1. BiovisION

    4  Pages

  2. AromavisION

    4  Pages

  3. iso TOC cube

    4  Pages

  4. EnvirovisION