Selectra XL Brochure
2Pages

{{requestButtons}}

Catalog excerpts

Selectra XL Brochure - 1

REAGENT SYSTEM • Two rotors with each 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. All positions can be assigned as R1, R2 and R3. Adapters for 5 ml bottles in 25 ml positions; • 10 pairs of 25 ml positions can be used for 50 ml bottles; • Reagent 1 volume 110 - 400 μl; • Reagent 2 volume 0 - 180 μl; • Reagent 3 volume 0 - 180 μl; • Reagent disk compartment is cooled to approx. 12°C below ambient temperature; • Preheated reagent needles with level detection and integrated mixer; • Typical reagent consumption 250 μl per test. SAMPLE SYSTEM • Sample rotor containing: - 80 barcode read samples positions; - Inner ring for 20 calibrators and 10 controls; • Stat and pediatric functionality; • Continuous loading; • Internal barcode reading; • Primary tubes (13 or 16 mm OD); • All positions can contain 5 ml or 10 ml primary tubes or sample cups; • Sample volume 1 - 30 μl per test, programmable in steps of 0.1 μl; • Sample probe with level detection and integrated mixer. SAMPLE PREDILUTION (MULTIPLE REAGENT MODE ONLY) • Pre-programmed ratios selectable from 1:2 to 1:100 with 3 diluents; • Automatic parent calibrator dilution. PIPETTING SYSTEM (2) • Hamilton syringes and valve block; • Reagent syringe 1000 μl; • Sample syringe 100 μl. CUVETTE ROTORS (2) • Semi-disposable rotor with 48 cuvettes. Path length 7 mm; • > 10.000 tests per rotor; • Min. measuring volume 220 μl; • Measuring temperature 37˚C, controlled by Peltier elements. WASHING UNITS (2) • Cuvette-washing with 4 x 500 μl of water. The unit is equipped with liquid sensors. Waste is separated into diluted and concentrated (sample/ reagent mixture and optional ISE-unit) waste. Cuvettes are dried before use. LIGHT SOURCE (2) • Quartz-iodine lamp 12V-20W. OPTICS & WAVELENGTH RANGE • 2 optical units with each a 8 position filter wheel; • Automatic wavelength selection by 8-position filterwheel (340, 376, 405, 436, 505, 546, 578 and 620 nm); • Other wavelenghts available on request; • Half bandwidth 8 to 12 nm. PHOTOMETRIC RANGE • -0.1 to 3.0 Absorbance. ANALYTICAL MODES • Kinetic measurement with linearity check; • Bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction; • Two point measurement; • Graphic plot of all measuring points; • Automatic rerun with sample reduction; • Non-linear calibration curves. AMBIENT TEMPERATURE • 15-32°C; • Maximum humidity 80%. About ELITech Clinical Systems… CALCULATION MODES • Prozone check for immunology tests; • Cut-off declaration. CERTIFICATES • CE; • CB; • UL. LANGUAGES • English, German, Spanish, French, Italian, Chinese and Dutch; • Other languages on request. MEASUREMENT CAPABILITIES (DUAL REAGENT MODE) • Reagent Absorbance (bichromatic) before sample addition; • Kinetic 1 for 4.5 minutes after sample addition (can be used as sample blank for Kinetic 2); • Kinetic 2 for 4 minutes after reagent 2 addition; • Kinetic 1+2 for 8.5 minutes after sample addition; • Sample blank (bichromatic) before reagent 2; • Endpoint (bichromatic) 4.5 minutes after sample addition or 11.5 minutes after sample addition; • Kinetic 1, Kinetic 2 or Kinetic 1 + 2 can contain a minimum measuring time or two points for two-point measurements. Robust, Always gets the job done DIMENSIONS (FLOORSTANDING) • 117 x 115 x 77 cm (W x H excl. Monitor x D) Trouble Free Operations with True workhorsereliability proven system Simplifies lab operations & reduces error Best in class operator interface, easy to train, Right Results, On Time with mistake Designedand error proofing reducing capabilities BAR CODE READER • Hand held CCD bar code reader (can read all common bar codes) used for test requisition and reagent identification. Best vendor services, application & lab operations support Management of difficult samples Cost effective, minimizes labor, maintenance & operate & maintain Proven methodologies, referenced and traceable CONCENTRATED WASTE • Separate waste container for concentrated waste. With over 50 years of proven experience in the design and manufacture of award winning BenchTop laboratory products, the Selectra Series is recognized worldwide for robustness and reliability. Together with a dedicated range of ready-to-use reagents from ELITech Clinical Systems, the Selectra Series provides an ideal chemistry solution for laboratory locations that are closer to the patient. Over the past decades, the ELITech Group Companies have established a solid distribution network that operates world-wide. More than twenty thousands of customers have experienced the quality, convenience and reliability of ELITech products. Local support is provided by dedicated and well trained sales and services organization. COMPUTER • Minimum requirements: - Pentium based: 800 MHz; - RAM 128 MB; - Monitor VGA 1024 x 768 pixels; - Hard Disk: 2 GB; - Floppy: 3,5” (1.44 MB); - CD ROM drive; - Windows 2000; - 1 USB for analyser; 1 serial port for host; 1 or 2 printer port(s). PRINTER • The application supports two printers simultaneously; one for patient reports and one for calibration and system data; • Most printers supported by Windows can be connected. MEASUREMENT CAPABILITIES (TRIPLE REAGENT MODE) • Additional timings available for three reagent system. CHEMISTRY workstation Distributor contact information: Content of this document is subject to change without prior notification Selectra XL® is a registered trademark of Vital Scientific BV Delivering Trouble Free Results Laboratories can Trust MEASUREMENT CAPABILITIES (SINGLE REAGENT MODE) • Reagent Absorbance (bichromatic) before sample addition; • Kinetic during 7 minutes after sample addition; • End Point (Bichromatic) 11.5 minutes after sample addition; • Kinetic can contain two points for two-point measurements. ELITech Clinical Systems is a global leader in BenchTop Chemistry Systems, with over 15,000 Chemistry Systems delivered. Our mission is to enable better medical decisions by bringing high-value diagnostics solutions and services to laboratories that are closer to the patient (proximity laboratories). ELITech Clinical Systems leadership originates from our ability to continuously provide differentiated products and services focused to proximity laboratories. ELITech Clinical Systems markets the Selectra Series, designed to deliver trouble-free results laboratories can trust. QUALITY CONTROL • Up to 15 different controls can be defined, 3 per test; • Westgard rules; • Levey-Jennings plots. THROUGHPUT • Up to 360 tests per hour; • Up to 450 tests per hour with ISE unit. Delivering trouble free results Belgium Brazil France Italy Middle East & Africa Serbia Switzerland The Netherlands T: + 44 1442 869320 UK United States T: + 1 855 354 8324 + 1 855 - ELITECH

Open the catalog to page 1

All ELITech Group catalogs and technical brochures

  1. ESBL ELITe

    2 Pages

  2. ELITe MGB®

    2 Pages

  3. Envoy 500+

    4 Pages

  4. Microlab 400

    2 Pages

  5. ENVOY-500

    4 Pages

  6. chlorochek

    4 Pages

  7. ELITe GALAXY

    2 Pages

  8. NANODUCT

    4 Pages

  9. ELIchrom

    2 Pages

  10. ELITe STAR

    2 Pages

  11. Flexor EL150

    2 Pages

  12. Flexor EL80

    2 Pages

Archived catalogs