Catalog excerpts
High performance calibration systems for professionals
Open the catalog to page 1A perfect solution for in-house and factory calibrations In-House Calibration at Your Facility To ensure accurate measurements it is essential to perform calibrations of probes and sensors on a regular basis. When setting up your own calibration laboratory it is important to use appropriate instrumentation and optimal room facilities. For temperature calibrations the ValSuite Pro calibration and validation software can be integrated with Ellab Dry Blocks, LiquiCal baths and the Ellab Temperature Standard (ETS) for a complete and automated calibration. Ellab calibration equipment has a...
Open the catalog to page 2Software Platforms For trouble free operation the ValSuite and ETSSuite software are available offering safe, intuitive and easy execution of the pre-defined operation procedures, all of which are FDA 21 CFR Part 11 compliant. ValSuite™ Pro Ellab’s highly sophisticated and very advanced validation software package with integrated calibration functionality offers manual, semi-automatic and full-automatic calibration of Ellab temperature probes and sensors. Our ValSuite software documents and guides you through the complete calibration process. The database structure in the software enables...
Open the catalog to page 3Calibration ValSuite Pro and Plus software allow for manual, semiautomatic or full-automatic pre and post calibrations of probes ensuring consistency, efficiency and proper documentation. Using the intuitive menus all data necessary for calibration is processed, generating offset values that are stored in the probes or software database. Calibration Set-up The ValSuite Pro software, in combination with the ETS, LiquiCal baths or Dry Blocks provide an automatic set-up, which simplifies the calibration routine eliminating errors and saving time. Ellab calibration and validation software uses...
Open the catalog to page 4Temperature Reference Instrument It is recommended that a reference instrument that is traceable to an accredited body such as SP or NLP in Europe or NIST in the US is used. The ETS is a robust , completely self-contained measurement system with integrated but also separated electronics for calibration and temperature A/D conversions which allows for extremely accurate temperature calibrations. The traceable ETS allows for temperature measurements by converting resistance into temperature using its built-in algorithms. When connected to the ValSuite software the bath/dry-block and ETS...
Open the catalog to page 5LiquiCal™ Solutions LiquiCal is a range of high performance liquid baths used for high precision temperature calibrations. The baths can be controlled via the ValSuite software allowing for an automated calibration and ramp control. It can also be used as a stand-alone unit. LiquiCal provides high temperature stability along with a large immersion depth, fast temperature change and quiet run. LiquiCal™ Features The models cover temperatures from -80 to 300 °C. The LiquiCal LL, SL and HL all have the same exterior dimensions, bath openings and liquid filling volume. The LiquiCal SM/HM micro...
Open the catalog to page 6Dry Block Solutions When a calibration at low and high temperatures is required, or when mobility is needed, a transportable Ellab Dry Block system is available. The high stability throughout the entire calibration zone is achieved by using an advanced and intuitive menu-driven controller with an easy to read color display. The Dry Blocks also incorporate a dual-zone heating technology where each heating zone is individually controlled to compensate for possible head loss over the top. Additionally, a line of custom made inserts that consist of wells that fit Ellab sensors/probes perfectly...
Open the catalog to page 7Since the late 1940’s Ellab A/S has been a leading manufacturer of process validation and monitoring systems used in the food, medical device and pharmaceutical industries. Calibration Certifications and Service Ellab maintains a complete calibration facility for annual certifications and service. Ellab A/S temperature, resistance, pressure and humidity calibration laboratory is accredited according to ISO 17025 by DANAK under registration no. 520. Service and maintenance contracts are available. Rental & Demos Demo systems are available for trial and rental. Please contact your local Ellab...
Open the catalog to page 8All Ellab Validation & Monitoring Solutions catalogs and technical brochures
-
RL4512 transmitter
1 Pages
-
RL4502/09 transmitter
2 Pages
-
RL4106 transmitter
2 Pages
-
RL4001/02 transmitter
1 Pages
-
RL4805/06 transmitter
1 Pages
-
Calibration Solutions
8 Pages
-
SteriSense®
2 Pages
-
E-Val™ Pro
2 Pages
-
Thermocouple Sensor
2 Pages
-
6 Bar Pressure Sensor
2 Pages
-
8 Bar Pressure Sensor
2 Pages
-
Automarker Sensor
2 Pages
-
Bowie Dick Sensor
2 Pages
-
Rugged Temperature Sensor
2 Pages
-
Rigid Temperature Sensor
2 Pages
-
Ellab-Validation-Solutions-ENG
12 Pages
-
Ellab-Temperature-Indicator
8 Pages