1. Catalogs
  2. Ellex
  3. Integre Pro Scan®

Integre Pro Scan®

Integre Pro Scan®

Integre Pro Scan®

Product catalog summary
Overview: The document provides comprehensive details about the Integre® Pro laser systems, specifically designed for retinal photocoagulation treatments. These systems are equipped with various wavelengths and configurations to effectively address different retinal conditions.
Key Features:
  • Wavelength Options: Integre® Pro lasers are available in single or dual-wavelength configurations, including Green (532 nm), Yellow (561 nm), and Yellow-Red (561 nm and 670 nm), offering versatile treatment applications.
  • Uniform Energy Distribution: The proprietary dual-mode laser cavity ensures uniform energy distribution across the spot diameter, eliminating hotspots and ensuring consistent treatment outcomes.
  • High Precision Performance: The system features a purpose-built slit lamp for optimal visualization and illumination, with conveniently located controls for ease of use.
Technical Specifications:
  • Laser Source: Solid-state laser diode and cavity.
  • Power: At the fiber port, Red: 1 watt, Yellow: 1.5 watts, Green: 1.5 watts. At the cornea, Red: 50 – 1000 mW, Yellow: 50 – 1500 mW, Green: 50– 1500 mW.
  • Exposure Time: Ranges from 10 ms to 8.0 s, with different modes for pattern scanning and single spot applications.
  • Spot Size: Continuously variable from 50 to 1000 μm, with specific ranges for pattern scanning mode.
  • Cooling: Air-cooled system.
Safety and Compliance: The laser systems are classified as Class 4 laser products per IEC60825-1:2014, with specific safety warnings to avoid eye or skin exposure to direct or scattered radiation.
Applications: Integre® Pro systems are suitable for a wide range of retinal treatments, including focal treatment in the macular area and panretinal photocoagulation (PRP) in the periphery, providing predictable and consistent outcomes across various pathologies.
Additional Features:
  • User Interface: The system includes a user-friendly touchscreen interface for easy adjustment of treatment parameters.
  • Photocoagulation Modes: Offers both SingleSpot and Pattern Scanning technologies, with customizable shooting modes for different treatment needs.
Specifications: The document outlines the specifications for a laser device used in retinal photocoagulation, operating in two modes: Repeat Mode and SingleSpot Mode, both with a time range from 50 ms to 1.0 s. The weight of the laser is specified as 32 kg (71 lbs) and 35 kg (77 lbs) for the laser only. The dimensions are 62 x 76 x 47 cm (24 x 30 x 19 inches).
Procedures: The document mentions the use of the laser in retinal photocoagulation, a medical procedure used to treat retinal conditions.
Key Parameters: The key parameters include the operational modes (Repeat Mode and SingleSpot Mode) and the time range for each mode (50 ms to 1.0 s).
See more

Catalog excerpts

Integre Pro Scan®-1

Laser Range SINGLESPOT PATTERN SCANNING Retinal Photocoagulation

 Open the catalog to page 1
Integre Pro Scan®-2

Laser range ion t a l u g a o c o t Retinal pho SINGLE OR DUAL-WAVELENGTH LASER Whether positioning focal treatment in the macular area, or performing PRP in the periphery, Integre® Pro lasers provide a comprehensive wavelength choice to treat a wide range of retinal conditions.[5] 2 PHOTOCOAGULATION MODES Integre® Pro laser range includes an extensive range of fully integrated systems, offering a wide array of parameters, tailored to the treatment of retinal pathologies. SingleSpot technology Absorption (cm-1) SingleSpot technology Pattern scanning technology The following wavelength configurations...

 Open the catalog to page 2
Integre Pro Scan®-3

DESIGNED WITH YOU IN MIND Highly intuitive tablet and all-in-one laser/slit lamp interface that’s been designed exactly with your needs in mind. User-friendly touchscreen interface means you can adjust all treatment parameters, including laser power, pulse duration, pattern selection and pattern size quickly and easily. SingleSpot technology Characterized by the use of long pulse durations (100-200ms), Integre® Pro offers customizable shooting modes for the implementation of thermal treatments such as leaking blood vessels sealing (focal laser photocoagulation): Single, repeat, continuous, etc....

 Open the catalog to page 3
Integre Pro Scan®-4

Laser Range Laser Source Solid-state laser diode and cavity 1 Yellow-red configuration: 561 nm and 670 nm 2 Yellow configuration: 561 nm 3 Green configuration: 532 nm Power at the fiber port Red: 1 watt. Yellow: 1.5 watts. Green: 1.5 watts Aiming Beam Electrical Requirements Exposure Time Pattern Scanning mode: 10 to 30 ms SingleSpot mode: 10 ms to 8.0 s Spot Size Pattern Scanning mode: 100 to 500 μm, continuously variable SingleSpot mode: 50 to 1000 μm, continuously variable Repeat Mode Pattern Scanning mode: N/A, SingleSpot mode: 50 ms to 1.0 s Dimensions (HxWxD) 62 x 76 x 47 cm, 24 x 30 x...

 Open the catalog to page 4

All Ellex catalogs and technical brochures

  1. Ultra Q

    2  Pages

  2. Solo

    2  Pages

  3. Tango Neo

    4  Pages

  4. Integre Pro

    4  Pages