MAX

MAX

MAX

Product catalog summary
Introduction to MAX™
MAX™ is an advanced analyser developed by Prism Analytical Technologies, combining chromatography and absorption spectroscopy for complex sample measurement. It features a patent-pending technology for enhanced sensitivity and detection limits in the parts per trillion (ppt) range, offering a large dynamic range and avoiding detector contamination.

Key Features
  • Capability to quantify hundreds of compounds per analysis, including co-eluting compounds, isomers, and isotopes.
  • Large dynamic range spanning nine orders of magnitude.
  • Factory-supplied, transferable calibrations that do not require recalibration.
  • Operates without a turbo pump and uses nitrogen instead of helium or hydrogen.
  • Low maintenance with a one-day installation process.

Applications
  • Source Testing
  • Pesticides and Herbicides Analysis
  • Petroleum Product Testing
  • Digester/Landfill Gas Testing
  • Process Monitoring
  • Ambient Air Testing

Operational Modes
  • FTIR Mode: Utilizes MultiGas 2030™ FTIR Gas Analyser, performing U.S. EPA Method 320 and other FTIR methods with a sample flow of 1-8 L/min and a 5.11 m multiple pass gas cell.
  • GC/FTIR Mode: Combines a miniature GC with MultiGas for U.S. EPA Method 18, featuring a 30m MTX 624 column and a self-heating column range of 35-230°C.

Software and Accessories
  • Proprietary MAX software for data collection and analysis in both FTIR and GC/FTIR modes.
  • Accessories include TDT Sampler, Desorber, Autosampler, and Ethernet communication capabilities.

Technical Specifications
  • Requires high purity nitrogen source at 40 PSI.
  • Operates on 100-240 VAC, 50/60 Hz with a maximum power consumption of 750 Watts.

Contact Information
For further details, contact Prism Analytical Technologies or visit their website.
See more

Catalog excerpts

MAX-1

The Absolute Standard in Analytical Measurement

 Open the catalog to page 1
MAX-2

The Absolute Standard in Analytical Meaurement Prism Analytical Technologies is pleased to introduce MAX™. MAX™ is a new analyser that measures complex samples by combining the separation power of chromatography with the quantification power of absorption spectroscopy. MAX™ is based on a patent pending technology wherein eluting gases are statically analysed in a multi-pass gas cell for increased sensitivity. Analytical algorithms allow for spectral time averaging to further increase sensitivity and producedetection limits in the ppt range. Also, since detection is based on absorption spectroscopy,...

 Open the catalog to page 2
MAX-3

MAX™ Operational Modes FTIR Mode GC/FTIR Mode • Performs U.S. EPA Method 320, ASTM D6348 and other EPA FTIR methods • 1 – 8 L/min sample flow • 1 scan per second • LN2 16um MCT detector • 5.11 m Multiple pass gas cell • Operating at 191°C FTIR calibration library in ppmv*m (191°C) Single digit ppm MDLs for most compounds • Performs U.S. EPA Method 18 GC Specification • 30m MTX 624 • 0.25 – 7 mL/min N2 flow • 35 – 230 C self-heating column FTIR Specification • MultiGas 2030™ FTIR • 4.0 cm-1 resolution at 191°C GC/FTIR calibration library in ng (191°C) Single digit ppb MDLs for most compounds 0.5...

 Open the catalog to page 3
MAX-4

MAX™ is trademark of Prism Analytical Technologies, Inc. Mt Pleasant, MI. MultiGas™ is trademark of MKS Instruments, Inc., Andover, MA Bulletin 701-02156 ©Copyright 2016, Prism Analytical Tecnhologies, Inc., All rights reserved. UK