video corpo

ES 350

ES 350

Product catalog summary
Electrosurgical Unit ES350 Overview
This document provides technical specifications and features of the Electrosurgical Unit ES350, designed for medical procedures requiring precision cutting and coagulation.

Compliance and Standards
The unit complies with EN 60601-1 and EN 60601-2-2 standards, ensuring safety and performance in medical environments.

Safety Features
  • Protection against electric shock with specified class and grade.
  • Low and high-frequency leakage currents are controlled.
  • Defibrillation pulse proof and NEM System for enhanced safety.
  • Automatic self-test of generator and accessories upon power-on.
  • Generator overload protection.

Operating Specifications
  • Generator operation frequency: 333 kHz.
  • Automatic start and stop of bipolar coagulation with real-time monitoring.
  • Automatic power regulation with 5 levels of adjustment.
  • Remote program selection via footswitch.

Monopolar and Bipolar Modes
  • Monopolar cutting includes pure cutting, cutting with haemostasis (I, II, III), urological, and endoscopic cutting.
  • Monopolar coagulation includes soft, forced, spray, and hybrid coagulation.
  • Bipolar cutting and coagulation with AutoStart/AutoStop features.

Power and Dimensions
  • Power supply: 220-240 V or 110-120 V, 50/60 Hz.
  • Rated power input: 1080 VA.
  • Dimensions: Length 420 mm, Width 415 mm, Height 180 mm.
  • Weight: 9.6 kg.

Additional Features
  • Spectrum Result System for constant control and volume regulation.
  • Program memory and MultiSwitch for remote program changes.
  • Special endoscopic and new monopolar modes.
  • Easy-to-clean flat front panel with push-buttons for mode and power regulation.

Contact Information
EMED SP. Z O. O. SP. K., ul. Ryżowa 69a, 05-816 Opacz-Kolonia, Poland. Tel: +48 22 723 08 00, Email: [email protected], Website: www.emed.pl

Document Reference
2021.10.K44.ES350.EN
See more

Catalog excerpts

ES 350-1

Electrosurgical unit ES350 MultiSwitch: remote SAFETY FEATURES program change Protection against electric shock: Class Special endoscopic modes Grade Low-frequency leakage currents New monopolar modes High-frequency leakage currents Generator operation frequency Monopolar modes Defibrillation pulse proof activation: footswitch NEM System or handle AUTOTEST Monopolar and bipolar OVERLOAD modes can be activate with one footswitch MONOPOLAR CUTTING Pure cutting Activation of bipolar Cutting with haemostasis I coagulation: footswitch Cutting with haemostasis II or AutoStart Cutting with haemostasis III Urological cutting Flat front panel, Endoscopic cutting easy to clean, with push-buttons for modes MONOPOLAR COAGULATION and power regulation Soft coagulation Bipolar resection I CF in accordance with EN 60601-1 in accordance with EN 60601-2-2 333 [kHz] in accordance with EN 60601-2-2 neutral electrode control self-test of generator and accessories after switching the power on, service codes display generator overload protection 400 [W] for 150 [ Ω] 180 [W] for 200 [Ω] 150 [W] for 200 [Ω] 150 [W] for 200 [Ω] 9 levels/ 400 [W] for 200 [Ω] 9 levels/ 400 [W] for 300 [Ω] Forced coagulation Spray coagulation Hybrid coagulation BIPOLAR CUTTING Pure Bipolar cutting 3 Urological bipolar cutting BIPOLAR COAGULATION Bipolar coagulation AutoStart / AutoStop 120 [W] for 50 [Ω] automatic start and stop of bipolar coagulation OTHER FEATURES Spectrum Result System Constant control Volume control Program memory MultiSwitch Outputs WEIGHT AND DIMENSIONS Length Width Height Weight POWER SUPPLY Supply voltage Rated power input automatic power regulation real-time monitoring of all parameters 5 levels remote program selection by footswitch 2 monopolar, 1 bipolar EMED SP. Z O. O. SP. K. | ul. Ryżowa 69a | 05-816 Opacz-Kolonia | Poland | tel: +48 22 723 08 00 e-mail:

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.